17 research outputs found

    Large variations in the practice patterns of surgical antiseptic preparation solutions in patients with open and closed extremity fractures : a cross-sectional survey

    Get PDF
    Surgically-managed fractures, particularly open fractures, are associated with high rates of surgical site infections (SSIs). To reduce the risk of an SSI, orthopaedic surgeons routinely clean open fracture wounds in the emergency department (ED) and then apply a bandage to the open wound. Prior to the surgical incision, it is standard practice to prepare the fracture region with an antiseptic skin solution as an additional SSI prevention strategy. Multiple antiseptic solutions are available. To explore the variation in practice patterns among orthopaedic surgeons regarding antiseptic solution use in the ED and antiseptic preparatory techniques for fracture surgery. We developed a 27-item survey and surveyed members of several orthopaedic associations. Two hundred and-ten surveys were completed. 71.0% of respondents irrigate the open wound and skin in the ED, primarily with saline alone (59.7%) or iodine-based solutions (32.9%). 90.5% of responders indicated that they dress the open wound in the ED, with 41.0% applying a saline-soaked bandage and 33.7% applying an iodine-soaked dressing (33.7%). In their surgical preparation of open fractures, 41.0% of respondents used an iodine-based solution, 26.7% used a chlorhexidine gluconate (CHG)-based solution, and 31.4% used a combination of the two. In closed fractures, 43.8% of respondents used a CHG-based solution, 28.1% used an iodine-based solution, and 27.1% used a combination. Despite theoretical concerns about the use of alcohol in open wounds, 51.4% used alcohol-based solutions or alcohol alone during skin preparation of open fractures. A lack of consensus exists regarding use of antiseptic surgical preparation solutions for fractures. High-quality clinical research is needed to assess the effectiveness of different surgical antiseptic preparation solutions on patient outcomes in fracture populations. The online version of this article (10.1186/s13756-018-0440-z) contains supplementary material, which is available to authorized users

    Fracture fixation in the operative management of hip fractures (FAITH): an international, multicentre, randomised controlled trial

    Get PDF
    © 2017 Elsevier Ltd Background Reoperation rates are high after surgery for hip fractures. We investigated the effect of a sliding hip screw versus cancellous screws on the risk of reoperation and other key outcomes. Methods For this international, multicentre, allocation concealed randomised controlled trial, we enrolled patients aged 50 years or older with a low-energy hip fracture requiring fracture fixation from 81 clinical centres in eight countries. Patients were assigned by minimisation with a centralised computer system to receive a single large-diameter screw with a side-plate (sliding hip screw) or the present standard of care, multiple small-diameter cancellous screws. Surgeons and patients were not blinded but the data analyst, while doing the analyses, remained blinded to treatment groups. The primary outcome was hip reoperation within 24 months after initial surgery to promote fracture healing, relieve pain, treat infection, or improve function. Analyses followed the intention-to-treat principle. This study was registered with ClinicalTrials.gov, number NCT00761813. Findings Between March 3, 2008, and March 31, 2014, we randomly assigned 1108 patients to receive a sliding hip screw (n=557) or cancellous screws (n=551). Reoperations within 24 months did not differ by type of surgical fixation in those included in the primary analysis: 107 (20%) of 542 patients in the sliding hip screw group versus 117 (22%) of 537 patients in the cancellous screws group (hazard ratio [HR] 0·83, 95% CI 0·63–1·09; p=0·18). Avascular necrosis was more common in the sliding hip screw group than in the cancellous screws group (50 patients [9%] vs 28 patients [5%]; HR 1·91, 1·06–3·44; p=0·0319). However, no significant difference was found between the number of medically related adverse events between groups (p=0·82; appendix); these events included pulmonary embolism (two patients [\u3c1%] vs four [1%] patients; p=0·41) and sepsis (seven [1%] vs six [1%]; p=0·79). Interpretation In terms of reoperation rates the sliding hip screw shows no advantage, but some groups of patients (smokers and those with displaced or base of neck fractures) might do better with a sliding hip screw than with cancellous screws. Funding National Institutes of Health, Canadian Institutes of Health Research, Stichting NutsOhra, Netherlands Organisation for Health Research and Development, Physicians\u27 Services Incorporated

    Correction to: Cluster identification, selection, and description in Cluster randomized crossover trials: the PREP-IT trials

    Get PDF
    An amendment to this paper has been published and can be accessed via the original article

    Patient and stakeholder engagement learnings: PREP-IT as a case study

    Get PDF

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    Get PDF
    Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (fo

    The Radiographic Union Score for Hip (RUSH) identifies radiographic nonunion of femoral neck fractures

    Full text link
    BACKGROUND: The Radiographic Union Score for Hip (RUSH) is a previously validated outcome instrument designed to improve intra- and interobserver reliability when describing the radiographic healing of femoral neck fractures. The ability to identify fractures that have not healed is important for defining nonunion in clinical trials and predicting patients who will likely require additional surgery to promote fracture healing. We sought to investigate the utility of the RUSH score to define femoral neck fracture nonunion. QUESTIONS/PURPOSES: (1) What RUSH score threshold yields at least 98% specificity to diagnose nonunion at 6 months postinjury? (2) Using the threshold identified, are patients below this threshold at greater risk of reoperation for nonunion and for other indications? METHODS: A representative sample of 250 out of a cohort of 725 patients with adequate 6-month hip radiographs was analyzed from a multinational elderly hip fracture trial (FAITH). All patients had a femoral neck fracture and were treated with either multiple cancellous screws or a sliding hip screw. Two reviewers independently determined the RUSH score based on the 6-month postinjury radiographs and interrater reliability was assessed with the interclass correlation coefficient (ICC). There was substantial reliability between the reviewers assigning the RUSH scores (ICC, 0.81; 95% confidence interval [CI], 0.76-0.85). The RUSH score is a checklist-based system that quantifies four measures of healing: cortical bridging, cortical fracture disappearance, trabecular consolidation, and trabecular fracture disappearance.. Fracture healing was determined by two independent methods: (1) concurrently by the treating surgeon using both clinical and radiographic assessments as per routine clinical care; and (2) retrospectively by a Central Adjudication Committee using complete obliteration of the fracture line on radiographs alone. Receiver operating characteristic tables were used to define a RUSH threshold score that was > 98% specific for fracture nonunion. RESULTS: A threshold score of < 18 was associated with a 100% specificity (95% CI, 97%-100%) and a positive predictive value of 100% (95% CI, 73%-100%) for radiographic nonunion. In contrast, using the fracture healing assessments of the treating surgeons failed to identify a useful discriminatory nonunion threshold and the highest positive predictive value was 43%. With respect to complications, patients with RUSH scores below 18 had greater risk of undergoing reoperation for nonunion (reoperation when < 18: six of 13 [46%]; reoperation when ≥ 18: 11 of 237 [54%]; relative risk [RR], 9.9 [95% CI, 4.4-22.7]; p < 0.001) and for all indications (reoperation when < 18: eight of 13 [62%]; reoperation when ≥ 18: 54 of 237 [38%]; RR, 2.7 [95% CI, 1.7-4.4]; p = 0.004). CONCLUSIONS: The 6-month RUSH score is a reliable method for assessing radiographic healing. Our results highlight the discordance between radiographic determinations and clinician assessments of fracture healing and stress the need for clinical data to be incorporated in research studies evaluating fracture healing. LEVEL OF EVIDENCE: Level III, diagnostic study

    Vitamin D use and health outcomes after surgery for hip fracture

    No full text
    Daily administration of vitamin D is important for maintaining bone homeostasis. The orthopedic community has shown increased interest in vitamin D supplementation and patient outcomes after fracture. The current study used data from a large hip fracture trial to determine the proportion of patients who consistently used vitamin D after hip fracture surgery and to determine whether supplementation was associated with improved health-related quality of life and reduced reoperation rates. The FAITH study is a multicenter trial of elderly patients with femoral neck fracture treated with internal fixation. The current study asked a subset of patients included in the FAITH study about vitamin D supplementation and categorized them as consistent users, inconsistent users, or nonusers. This study also evaluated whether supplementation was associated with improved quality of life and reduced reoperation rates. The final analysis included 573 patients (mean age, 74.1 years; female, 66.3%; nondisplaced fractures, 72.4%). A total of 18.7% of participants reported no use of vitamin D, 35.6% reported inconsistent use, and 45.7% reported consistent use. Adjusted analysis found that consistent supplementation was associated with a 2.42 increase of the Short Form-12 physical component score 12 months postoperatively (P=.033). However, supplementation was not associated with reduced reoperation rates (P=.386). Despite guidelines recommending vitamin D supplementation, a low proportion of elderly patients with hip fracture use vitamin D consistently, suggesting a need for additional strategies to promote compliance. This study found that the use of vitamin D was associated with a statistically significant but not clinically significant improvement in health-related quality of life after hip fracture. Further research is needed to confirm these findings

    A scoping review of intimate partner violence assistance programmes within health care settings

    No full text
    Background: The lifetime prevalence of intimate partner violence (IPV) for women presenting to health care settings is estimated to be 38–59%. With the goal of providing help to victims of abuse, numerous IPV assistance programmes have been developed and evaluated across multiple health care settings. Objective: Our scoping review provides an overview of this literature to identify key areas for potential evidence-based recommendations and to focus research priorities. Methods: We conducted a search of MEDLINE, Embase, Cumulative Index of Nursing and Allied Health Literature, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and psycINFO. We used broad eligibility criteria to identify studies that evaluated the effectiveness of IPV assistance programmes delivered within health care settings. We completed all screening and data extraction independently and in duplicate. We used descriptive statistics to summarize all data. Results: Forty-three studies met all eligibility criteria and were included in our scoping review. Nine categories of assistance programmes were identified: counselling/advocacy, safety assessment/planning, referral, providing IPV resources, home visitation, case management, videos, provider cueing, and system changes. Characteristics of programmes amongst studies frequently reporting positive results included those in which one type of active assistance was used (77.8% of studies reported positive results), a counsellor, community worker, or case manager provided the intervention (83.3% of studies reported positive results), and programmes that were delivered over more than five sessions (100.0% of studies reported positive results). Conclusions: IPV assistance programmes are heterogeneous with regards to the types of assistance they include and how they are delivered and evaluated. This heterogeneity creates challenges in identifying which IPV assistance programmes, and which aspects of these programmes, are effective. However, it appears that many different types of IPV assistance programmes can have positive impacts on women

    Large variations in the practice patterns of surgical antiseptic preparation solutions in patients with open and closed extremity fractures : a cross-sectional survey

    No full text
    Surgically-managed fractures, particularly open fractures, are associated with high rates of surgical site infections (SSIs). To reduce the risk of an SSI, orthopaedic surgeons routinely clean open fracture wounds in the emergency department (ED) and then apply a bandage to the open wound. Prior to the surgical incision, it is standard practice to prepare the fracture region with an antiseptic skin solution as an additional SSI prevention strategy. Multiple antiseptic solutions are available. To explore the variation in practice patterns among orthopaedic surgeons regarding antiseptic solution use in the ED and antiseptic preparatory techniques for fracture surgery. We developed a 27-item survey and surveyed members of several orthopaedic associations. Two hundred and-ten surveys were completed. 71.0% of respondents irrigate the open wound and skin in the ED, primarily with saline alone (59.7%) or iodine-based solutions (32.9%). 90.5% of responders indicated that they dress the open wound in the ED, with 41.0% applying a saline-soaked bandage and 33.7% applying an iodine-soaked dressing (33.7%). In their surgical preparation of open fractures, 41.0% of respondents used an iodine-based solution, 26.7% used a chlorhexidine gluconate (CHG)-based solution, and 31.4% used a combination of the two. In closed fractures, 43.8% of respondents used a CHG-based solution, 28.1% used an iodine-based solution, and 27.1% used a combination. Despite theoretical concerns about the use of alcohol in open wounds, 51.4% used alcohol-based solutions or alcohol alone during skin preparation of open fractures. A lack of consensus exists regarding use of antiseptic surgical preparation solutions for fractures. High-quality clinical research is needed to assess the effectiveness of different surgical antiseptic preparation solutions on patient outcomes in fracture populations. The online version of this article (10.1186/s13756-018-0440-z) contains supplementary material, which is available to authorized users

    Factors Associated with Revision Surgery after Internal Fixation of Hip Fractures

    No full text
    © 2018 Wolters Kluwer Health, Inc. All rights reserved. Background: Femoral neck fractures are associated with high rates of revision surgery after management with internal fixation. Using data from the Fixation using Alternative Implants for the Treatment of Hip fractures (FAITH) trial evaluating methods of internal fixation in patients with femoral neck fractures, we investigated associations between baseline and surgical factors and the need for revision surgery to promote healing, relieve pain, treat infection or improve function over 24 months postsurgery. Additionally, we investigated factors associated with (1) hardware removal and (2) implant exchange from cancellous screws (CS) or sliding hip screw (SHS) to total hip arthroplasty, hemiarthroplasty, or another internal fixation device. Methods: We identified 15 potential factors a priori that may be associated with revision surgery, 7 with hardware removal, and 14 with implant exchange. We used multivariable Cox proportional hazards analyses in our investigation. Results: Factors associated with increased risk of revision surgery included: female sex, [hazard ratio (HR) 1.79, 95% confidence interval (CI) 1.25-2.50; P = 0.001], higher body mass index (for every 5-point increase) (HR 1.19, 95% CI 1.02-1.39; P = 0.027), displaced fracture (HR 2.16, 95% CI 1.44-3.23; P \u3c 0.001), unacceptable quality of implant placement (HR 2.70, 95% CI 1.59-4.55; P \u3c 0.001), and smokers treated with cancellous screws versus smokers treated with a sliding hip screw (HR 2.94, 95% CI 1.35-6.25; P = 0.006). Additionally, for every 10-year decrease in age, participants experienced an average increased risk of 39% for hardware removal. Conclusions: Results of this study may inform future research by identifying high-risk patients who may be better treated with arthroplasty and may benefit from adjuncts to care (HR 1.39, 95% CI 1.05-1.85; P = 0.020)
    corecore