81 research outputs found

    A European arena for joint innovation in healthcare: The Platform for Innovation of Procurement and Procurement of Innovation (PiPPi)

    Get PDF
    Digital health; Health innovation; University hospitalSalut digital; Innovació sanitària; Hospital universitariSalud digital; Innovación en salud; Hospital universitarioBy 2000 the European Union (EU) had recognized that its innovation capacity was underperforming in comparison to similar competitors and trading partners. Although the EU has made an effort to stimulate public research and development (R&D) through policy tools like Pre-Commercial Procurement (PCP) and Public Procurement of Innovation (PPI), starting with the 2000 Lisbon strategy and continuing through the 2021 updated Guidance on Innovation Procurement, there has remained a gap in knowledge of and use of these tools, in particular within healthcare. The past decades have seen an explosion in the number and use of digital technologies across the entire spectrum of healthcare. Demand-driven R&D has lagged here, while new digital health R&D has largely been driven by the supply side in a linear fashion, which can have disappointing results. PCP and PPI could have big impacts on the development and uptake of innovative health technology. The Platform for Innovation of Procurement and Procurement of Innovation (PiPPi) project was a Horizon 2020-funded project that ran from December 2018 to May 2022 with a consortium including seven of Europe's premier research hospitals and the Catalan Agency for Health Information. To promote PCP and PPI, PiPPi established a virtual Community of Practice (CoP) that brings together all stakeholder groups to share and innovate around unmet healthcare needs. This perspective presents a brief history of PCP and PPI in Europe with a focus on digital innovation in healthcare before introducing the PiPPi project and its value proposition.This project received funding from the European Union's Horizon 2020 Research and Innovation Programme under Grant Agreement No. 826157

    Rapid malignant progression of an intraparenchymal choroid plexus papillomas

    Get PDF
    Background: Choroid plexus tumors (CPTs) are rare neoplasms accounting for only 0.3-0.6% of all brain tumors in adults and 2-5% in children. The World Health Organization (WHO) classification describes three histological grades: grade I is choroid plexus papilloma (CPP), grade II is atypical papilloma, and grade III is the malignant form of carcinoma. In adults, CPTs rarely have a supratentorial localization. Case Description: Here we report a very rare case of an intraparenchymal parietal CPP with a rapid histological transition from grade I to grade III WHO in a 67-year-old man, in <7 months. Conclusion: Because of the rarity of these oncotypes, descriptions of each new case are useful, mostly to consider this diagnostic entity in extraventricular brain tumors of adults, despite an unusual location

    SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam

    Get PDF
    SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(Tl) and of heat and ionization in Ge are presented.Comment: 30 pages, Latex, 11 figures. Submitted to NIM

    On the alpha activity of natural tungsten isotopes

    Full text link
    The indication for the alpha decay of 180-W with a half-life T1/2=1.1+0.8-0.4(stat)+-0.3(syst)x10^18 yr has been observed for the first time with the help of the super-low background 116-CdWO_4 crystal scintillators. In conservative approach the lower limit on half-life of 180-W has been established as T1/2>0.7x10^18 yr at 90% C.L. Besides, new T1/2 bounds were set for alpha decay of 182-W, 183-W, 184-W and 186-W at the level of 10^20 yr.Comment: 16 pages, 8 figures, accepted in Phys. Rev.

    Peripheral facial palsy following ventriculoperitoneal shunt. The lesson we have learned

    Get PDF
    The most frequent complications after shunt surgery are infective and obstructive. Other types are less common, and eventually occur due to technical errors during brain ventricular puncture, opening the intraperitoneal cavity or the tunnelling of the catheter between the two points. Although rare, there are well-reported complications related to the poor positioning of the distal catheter, with perforation of organs and tissues. We report a very rare case of a male patient with normal pressure hydrocephalus submitted to ventriculoperitoneal shunt. During tunnelling of the shunt stylet, a peripheral facial palsy due to injury to the extra cranial segment of the facial nerve occurred. To the best of our knowledge this is the second case described in Literature. The patient and the surgeon should be aware of this very rare but possible complication in shunt surgery being careful to the course of the facial nerve in the mastoid region

    A Cryogenic Underground Observatory for Rare Events: Cuore, an Update

    Get PDF
    CUORE is a proposed tightly packed array of 1000 TeO_{2} bolometers, each being a cube 5 cm on a side with a mass of 750 gms. The array consists of 25 vertical towers, arranged in a square, of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow- background searches for neutrinoless double beta decay of ^{130}Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals of various sizes (MIBETA) has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.Comment: in press: Nucl. Phys. of Russian Academy of Sc

    Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

    Get PDF
    The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.Comment: 28 pages, 7 figures. Submitted to Phys. Rev.

    Neutrinoless Double Beta Decay within QRPA with Proton-Neutron Pairing

    Get PDF
    We have investigated the role of proton-neutron pairing in the context of the Quasiparticle Random Phase approximation formalism. This way the neutrinoless double beta decay matrix elements of the experimentally interesting A= 48, 76, 82, 96, 100, 116, 128, 130 and 136 systems have been calculated. We have found that the inclusion of proton-neutron pairing influences the neutrinoless double beta decay rates significantly, in all cases allowing for larger values of the expectation value of light neutrino masses. Using the best presently available experimental limits on the half life-time of neutrinoless double beta decay we have extracted the limits on lepton number violating parameters.Comment: 16 RevTex page
    corecore