166 research outputs found

    Genetic bases of arrhythmogenic right ventricular Cardiomyopathy

    Get PDF
    Arrhythmogenic right ventricular cardiomyopathy (ARVC) is a heart muscle disease in which the pathological substrate is a fibro-fatty replacement of the right ventricular myocardium. The major clinical features are different types of arrhythmias with a left branch block pattern. ARVC shows autosomal dominant inheritance with incomplete penetrance. Recessive forms were also described, although in association with skin disorders

    Modeling Cardiovascular Diseases with hiPSC-Derived Cardiomyocytes in 2D and 3D Cultures

    Get PDF
    In the last decade, the generation of cardiac disease models based on human-induced pluripotent stem cells (hiPSCs) has become of common use, providing new opportunities to overcome the lack of appropriate cardiac models. Although much progress has been made toward the generation of hiPSC-derived cardiomyocytes (hiPS-CMs), several lines of evidence indicate that two-dimensional (2D) cell culturing presents significant limitations, including hiPS-CMs immaturity and the absence of interaction between dierent cell types and the extracellular matrix. More recently, new advances in bioengineering and co-culture systems have allowed the generation of three-dimensional (3D) constructs based on hiPSC-derived cells. Within these systems, biochemical and physical stimuli influence the maturation of hiPS-CMs, which can show structural and functional properties more similar to those present in adult cardiomyocytes. In this review, we describe the latest advances in 2D- and 3D-hiPSC technology for cardiac disease mechanisms investigation, drug development, and therapeutic studies

    A new locus for arrhythmogenic right ventricular cardiomyopathy (ARVD2) maps to chromosome 1q42-q43

    Get PDF
    Autosomal dominant arrhythmogenic right ventricular cardiomyopathy (ARVD, MIM 107970) is one of the major causes of juvenile sudden death. We have previously assigned the disease locus to chromosome 14q23-q24. Here we report on a novel variant of ARVD, which is transmitted associated to 1q42-q43 and is characterized by a concealed form, showing effort-induced polymorphic tachycardias. Since both loci ARVD1 and ARVD2 map in proximity of a-actinin genes, the possible implication of these myofibrillar proteins in the pathogenesis of ARVD is discussed. Two additional ARVD families, tested with markers of chromosomes 1q42-q43 and 14q23-q24, failed to show linkage, providing evidence of further genetic heterogeneit

    Setup and Validation of a Targeted Next-Generation Sequencing Approach for the Diagnosis of Lysosomal Storage Disorders.

    Get PDF
    Lysosomal storage disorders (LSDs) are monogenic diseases, due to accumulation of specific undegraded substrates into lysosomes. LSD diagnosis could take several years because of both poor knowledge of these diseases and shared clinical features. The diagnostic approach includes clinical evaluations, biochemical tests, and genetic analysis of the suspected gene. In this study, we evaluated an LSD targeted sequencing panel as a tool capable to potentially reverse this classic diagnostic route. The panel includes 50 LSD genes and 230 intronic sequences conserved among 33 placental mammals. For the validation phase, 56 positive controls, 13 biochemically diagnosed patients, and nine undiagnosed patients were analyzed. Disease-causing variants were identified in 66% of the positive control alleles and in 62% of the biochemically diagnosed patients. Three undiagnosed patients were diagnosed. Eight patients undiagnosed by the panel were analyzed by whole exome sequencing: for two of them, the disease-causing variants were identified. Five patients, undiagnosed by both panel and exome analyses, were investigated through array comparative genomic hybridization: one of them was diagnosed. Conserved intronic fragment analysis, performed in cases unresolved by the first-level analysis, evidenced no candidate intronic variants. Targeted sequencing has low sequencing costs and short sequencing time. However, a coverage >60Ă— to 80Ă— must be ensured and/or Sanger validation should be performed. Moreover, it must be supported by a thorough clinical phenotyping

    Characterization and preliminary risk assessment of road dust collected in Venice airport (Italy)

    Get PDF
    Road dust is a non-exhaust source that can significantly contribute to atmospheric particulate by resuspension. Beside the issue of the overcoming of guidelines limits for the air quality, the characterization of this matrix is of crucially high interest for the inherent toxicity of resuspended particles, that can act as carriers of heavy metals and toxic-carcinogenic components. In this paper, road dust collected in the Venice international airport is characterized with a multi-technique approach in order to identify the main pollutant sources and to highlight the differences between airside/landside places. The most polluted sites are identified and a preliminary risk assessment is performed taking into account ingestion, dermal intake and inhalation of fugitive particulate pathways. Specifically, the main sources are related to construction activities, anti-icing safety procedures, and brake, tire and road wear; streets are the most polluted landside places; PAHs, Na, Al, Cu, Zn, Ag, Cd are more concentrated in airside area; as regards the risk assessment As, BaP, Cr, Sb, BaA, and BbF are the most critical pollutants. Considering the high number of people passing or working in this airport and the ongoing works related to its enlargement which promotes the emission and the resuspension of fugitive dusts, this research addresses a fundamental step for the protection of potential receptors

    Clinical efficacy of Enzyme Replacement Therapy in paediatric Hunter patients, an independent study of 3.5 years

    Get PDF
    BACKGROUND: Hunter Syndrome is an X-linked lysosomal storage disorder due to the deficit of iduronate 2-sulfatase, an enzyme catalysing the degradation of the glycosaminoglycans (GAG) dermatan- and heparan-sulfate. Treatment of the disease is mainly performed by Enzyme Replacement Therapy (ERT) with idursulfase, in use since 2006. Clinical efficacy of ERT has been monitored mainly by the Hunter Outcome Survey (HOS) while very few independent studies have been so far conducted. The present study is a 3.5-years independent follow-up of 27 Hunter patients, starting ERT between 1.6 and 27 years of age, with the primary aim to evaluate efficacy of the therapy started at an early age (<12 years). METHODS: In this study, we evaluated: urinary GAG content, hepato/splenomegaly, heart valvulopathies, otorinolaryngological symptoms, joint range of motion, growth, distance covered in the 6-minute walk test, neurological involvement. For data analysis, the 27 patients were divided into three groups according to the age at start of ERT: ≤5 years, >5 and ≤ 12 years and > 12 years. Patients were analysed both as 3 separate groups and also as one group; in addition, the 20 patients who started ERT up to 12 years of age were analysed as one group. Finally, patients presenting a “severe” phenotype were compared with “attenuated” ones. RESULTS: Data analysis revealed a statistically significant reduction of the urinary GAG in patients ≤5 years and ≤ 12 years and of the hepatomegaly in the group aged >5 and ≤ 12 years. Although other clinical signs improved in some of the patients monitored, statistical analysis of their variation did not reveal any significant changes following enzyme administration. The evaluation of ERT efficacy in relation to the severity of the disease evidenced slightly higher improvements as for hepatomegaly, splenomegaly, otological disorders and adenotonsillar hypertrophy in severe vs attenuated patients. CONCLUSIONS: Although the present protocol of idursulfase administration may result efficacious in delaying the MPS II somatic disease progression at some extent, in this study we observed that several signs and symptoms did not improve during the therapy. Therefore, a strict monitoring of the efficacy obtained in the patients under ERT is becoming mandatory for clinical, ethical and economic reasons. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1186/s13023-014-0129-1) contains supplementary material, which is available to authorized users

    Missense mutations in Desmocollin-2 N-terminus, associated with arrhythmogenic right ventricular cardiomyopathy, affect intracellular localization of desmocollin-2 in vitro

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Mutations in genes encoding desmosomal proteins have been reported to cause arrhythmogenic right ventricular cardiomyopathy (ARVC), an autosomal dominant disease characterised by progressive myocardial atrophy with fibro-fatty replacement.</p> <p>We screened 54 ARVC probands for mutations in desmocollin-2 (<it>DSC2</it>), the only desmocollin isoform expressed in cardiac tissue.</p> <p>Methods</p> <p>Mutation screening was performed by denaturing high-performance liquid chromatography and direct sequencing.</p> <p>To evaluate the pathogenic potentials of the <it>DSC2 </it>mutations detected in patients affected with ARVC, full-length wild-type and mutated cDNAs were cloned in eukaryotic expression vectors to obtain a fusion protein with green fluorescence protein (GFP); constructs were transfected in neonatal rat cardiomyocytes and in HL-1 cells.</p> <p>Results</p> <p>We identified two heterozygous mutations (c.304G>A (p.E102K) and c.1034T>C (p.I345T)) in two probands and in four family members. The two mutations p.E102K and p.I345T map to the N-terminal region, relevant to adhesive interactions.</p> <p>In vitro functional studies demonstrated that, unlike wild-type DSC2, the two N-terminal mutants are predominantly localised in the cytoplasm.</p> <p>Conclusion</p> <p>The two missense mutations in the N-terminal domain affect the normal localisation of DSC2, thus suggesting the potential pathogenic effect of the reported mutations. Identification of additional DSC2 mutations associated with ARVC may result in increased diagnostic accuracy with implications for genetic counseling.</p

    Implementation and performances of the IPbus protocol for the JUNO Large-PMT readout electronics

    Full text link
    The Jiangmen Underground Neutrino Observatory (JUNO) is a large neutrino detector currently under construction in China. Thanks to the tight requirements on its optical and radio-purity properties, it will be able to perform leading measurements detecting terrestrial and astrophysical neutrinos in a wide energy range from tens of keV to hundreds of MeV. A key requirement for the success of the experiment is an unprecedented 3% energy resolution, guaranteed by its large active mass (20 kton) and the use of more than 20,000 20-inch photo-multiplier tubes (PMTs) acquired by high-speed, high-resolution sampling electronics located very close to the PMTs. As the Front-End and Read-Out electronics is expected to continuously run underwater for 30 years, a reliable readout acquisition system capable of handling the timestamped data stream coming from the Large-PMTs and permitting to simultaneously monitor and operate remotely the inaccessible electronics had to be developed. In this contribution, the firmware and hardware implementation of the IPbus based readout protocol will be presented, together with the performances measured on final modules during the mass production of the electronics

    Mass testing of the JUNO experiment 20-inch PMTs readout electronics

    Full text link
    The Jiangmen Underground Neutrino Observatory (JUNO) is a multi-purpose, large size, liquid scintillator experiment under construction in China. JUNO will perform leading measurements detecting neutrinos from different sources (reactor, terrestrial and astrophysical neutrinos) covering a wide energy range (from 200 keV to several GeV). This paper focuses on the design and development of a test protocol for the 20-inch PMT underwater readout electronics, performed in parallel to the mass production line. In a time period of about ten months, a total number of 6950 electronic boards were tested with an acceptance yield of 99.1%
    • …
    corecore