46 research outputs found

    A comparison of delayed SIR and SEIR epidemic models

    Get PDF
    In epidemiological research literatures, a latent or incubation period can be medelled by incorporating it as a delay effect (delayed SIR models), or by introducing an exposed class (SEIR models). In this paper we propose a comparison of a delayed SIR model and its corresponding SEIR model in terms of local stability. Also some numerical simulations are given to illustrate the theoretical results

    SEGMENTACJA MAS NOWOTWOROWYCH NA OBRAZACH ULTRASONOGRAFII PIERSI Z UŻYCIEM ZMODYFIKOWANEGO MODELU U-NET

    Get PDF
    Breast cancer causes a huge number of women’s deaths every year. The accurate localization of a breast lesion is a crucial stage. The segmentation of breast ultrasound images participates in the improvement of the process of detection of breast anomalies. An automatic approach of segmentation of breast ultrasound images is presented in this paper, the proposed model is a modified u-net called Attention Residual U-net, designed to help radiologists in their clinical examination to determine adequately the limitation of breast tumors. Attention Residual U-net is a combination of existing models (Convolutional Neural Network U-net, the Attention Gate Mechanism and the Residual Neural Network). Public breast ultrasound images dataset of Baheya hospital in Egypt is used in this work. Dice coefficient, Jaccard index and Accuracy are used to evaluate the performance of the proposed model on the test set. Attention residual u-net can significantly give a dice coefficient = 90%, Jaccard index = 76% and Accuracy = 90%. The proposed model is compared with two other breast segmentation methods on the same dataset. The results show that the modified U-net model was able to achieve accurate segmentation of breast lesions in breast ultrasound images.Każdego roku rak piersi powoduje ogromną liczbę zgonów kobiet. Dokładna lokalizacja zmiany piersi jest kluczowym etapem. Segmentacja obrazów ultrasonograficznych piersi przyczynia się do poprawy procesu wykrywania nieprawidłowości piersi. W tym artykule przedstawiono automatyczne podejście do segmentacji obrazów ultrasonograficznych piersi, proponowany model to zmodyfikowany U-net, nazwany Attention Residual U-net, zaprojektowany w celu wspomagania radiologów podczas badania klinicznego, w celu odpowiedniego określenia zasięgu guzów piersiowych. Attention Residual U-net jest połączeniem istniejących modeli (konwolucyjną siecią neuronową U-net, Attention Gate Mechanism  i Residual Neural Network). W tym badaniu wykorzystano publiczny zbiór danych obrazów ultrasonograficznych piersi szpitala Baheya w Egipcie. Do oceny wydajności zaproponowanego modelu na zbiorze testowym wykorzystano współczynnik Dice'a, indeks Jaccarda i dokładność. Attention Residual U-net może znacznie przyczynić się do uzyskania współczynnika Dice'a równego 90%, indeksu Jaccarda równego 76% i dokładności równiej 90%. Proponowany model został porównany z dwoma innymi metodami segmentacji piersi na tym samym zbiorze danych. Wyniki pokazują, że zmodyfikowany model U-net był w stanie osiągnąć dokładną segmentację zmian piersiowych na obrazach ultrasonograficznych piersi

    Rupture utérine sur utérus sain: complication du misoprostol (à propos d’un cas et revue de la littérature)

    Get PDF
    La rupture utérine sur utérus sain au 2ème et 3ème trimestre de grossesse est une complication obstétricale rare et grave mettant en jeu les pronostics vitaux maternels et fœtaux et le devenir obstétrical des patientes en l'absence de diagnostic et de prise en charge immédiate. Elle survient majoritairement sur un utérus cicatriciel et reste anecdotique sur un utérus sain. Nous rapportons le cas d'une patiente primigeste ayant présenté une rupture utérine sur un utérus non cicatriciel lors d'un déclenchement de travail par le misoprostol pour mort fœtale in utero (MFIU) sur retard de croissance intra utérin (RCIU) et oligoamnios sévère à 31 semaines d'aménorrhée (SA). Nous discutons à travers ce cas et la revue de la littérature, l'extrême prudence qu'il faut garder pour utiliser le misoprostol en cas de déclenchement du travail ainsi que les signes d'appel cliniques, les facteurs de risque, la méthodologie diagnostique et la prise en charge thérapeutique de cette entité rare mais potentiellement grave

    Kyste paratubaire tordu: à propos d’un cas rare de diagnostique difficile

    Get PDF
    Les kystes para tubaires sont des lésions fréquentes, et peuvent être responsables de complications à type de torsion d’annexe qui est rarissime et difficile à diagnostiquer. Cette pathologie est souvent confondue à une torsion ovarienne, la prise en charge dans les deux cas nécessite une intervention chirurgicale en urgence afin de tenter de conserver l’annexe. Nous rapportons un cas rare d’une jeune patiente opérée d’un kyste para tubaire bénin tordue de diagnostic difficile.Key words: Kysteparatubaire, torsion d´annexe, salpingectomi

    U-Net transfer learning backbones for lesions segmentation in breast ultrasound images

    Get PDF
    Breast ultrasound images are highly valuable for the early detection of breast cancer. However, the drawback of these images is low-quality resolution and the presence of speckle noise, which affects their interpretability and makes them radiologists’ expertise-dependent. As medical images, breast ultrasound datasets are scarce and imbalanced, and annotating them is tedious and time-consuming. Transfer learning, as a deep learning technique, can be used to overcome the dataset deficiency in available images. This paper presents the implementation of transfer learning U-Net backbones for the automatic segmentation of breast ultrasound lesions and implements a threshold selection mechanism to deliver optimal generalized segmentation results of breast tumors. The work uses the public breast ultrasound images (BUSI) dataset and implements ten state-of-theart candidate models as U-Net backbones. We have trained these models with a five-fold cross-validation technique on 630 images with benign and malignant cases. Five out of ten models showed good results, and the best U-Net backbone was found to be DenseNet121. It achieved an average Dice coefficient of 0.7370 and a sensitivity of 0.7255. The model’s robustness was also evaluated against normal cases, and the model accurately detected 72 out of 113 images, which is higher than the four best models

    OPTYMALIZACJA KLASYFIKACJI OBRAZÓW ULTRASONOGRAFICZNYCH TECHNIKĄ TRANSFER LEARNING: STRATEGIE DOSTRAJANIA I WPŁYW KLASYFIKATORA NA WSTĘPNIE WYTRENOWANE WARSTWY WEWNĘTRZNE

    Get PDF
    Transfer Learning (TL) is a popular deep learning technique used in medical image analysis, especially when data is limited. It leverages pre-trained knowledge from State-Of-The-Art (SOTA) models and applies it to specific applications through Fine-Tuning (FT). However, fine-tuning large models can be time-consuming, and determining which layers to use can be challenging. This study explores different fine-tuning strategies for five SOTA models (VGG16, VGG19, ResNet50, ResNet101, and InceptionV3) pre-trained on ImageNet. It also investigates the impact of the classifier by using a linear SVM for classification. The experiments are performed on four open-access ultrasound datasets related to breast cancer, thyroid nodules cancer, and salivary glands cancer. Results are evaluated using a five-fold stratified cross-validation technique, and metrics like accuracy, precision, and recall are computed. The findings show that fine-tuning 15% of the last layers in ResNet50 and InceptionV3 achieves good results. Using SVM for classification further improves overall performance by 6% for the two best-performing models. This research provides insights into fine-tuning strategies and the importance of the classifier in transfer learning for ultrasound image classification.Transfer Learning (TL) to popularna technika głębokiego uczenia stosowana w analizie obrazów medycznych, zwłaszcza gdy ilość danych jest ograniczona. Wykorzystuje ona wstępnie wyszkoloną wiedzę z modeli State-Of-The-Art (SOTA) i zastosowanie ich do konkretnych aplikacji poprzez dostrajanie (Fine-Tuning – FT). Jednak dostrajanie dużych modeli może być czasochłonne, a określenie, których warstw użyć, może stanowić wyzwanie. W niniejszym badaniu przeanalizowano różne strategie dostrajania dla pięciu modeli SOTA (VGG16, VGG19, ResNet50, ResNet101 i InceptionV3) wstępnie wytrenowanych na ImageNet. Zbadano również wpływ klasyfikatora przy użyciu liniowej SVM do klasyfikacji. Eksperymenty przeprowadzono na czterech ogólnodostępnych zbiorach danych ultrasonograficznych związanych z rakiem piersi, rakiem guzków tarczycy i rakiem gruczołów ślinowych. Wyniki są oceniane przy użyciu techniki pięciowarstwowej walidacji krzyżowej, a wskaźniki takie jak dokładność, precyzja i odzyskiwanie są obliczane. Wyniki pokazują, że dostrojenie 15% ostatnich warstw w ResNet50 i InceptionV3 osiąga dobre wyniki. Użycie SVM do klasyfikacji dodatkowo poprawia ogólną wydajność o 6% dla dwóch najlepszych modeli. Badania te zapewniają informacje na temat strategii dostrajania i znaczenia klasyfikatora w uczeniu transferowym dla klasyfikacji obrazów ultrasonograficznych

    Computer Vision-Based Approach for Automated Monitoring and Assessment of Gait Rehabilitation at Home

    Get PDF
    This study presents a markerless video-based human gait analysis system for automatic assessment of at-home rehabilitation. A marker-based MoCap system (Vicon) is used to evaluate the accuracy of the proposed approach. Additionally, a novel gait rehabilitation score based on the Dynamic Time Warping (DTW) algorithm is introduced, enabling quantification of rehabilitation progress. The accuracy of the proposed approach is assessed by comparing it to a marker-based MoCap system (Vicon), which is used to evaluate the proposed approach. This evaluation results in mean absolute errors (MAE) of 4.8° and 5.2° for the left knee, and 5.9° and 5.7° for the right knee, demonstrating an acceptable accuracy in knee angle measurements. The obtained scores effectively distinguish between normal and abnormal gait patterns. Subjects with normal gait exhibit scores around 97.5%, 98.8%, while those with abnormal gait display scores around 30%, 29%, respectively. Furthermore, a subject at an advanced stage of rehabilitation achieved a score of 65%. These scores provide valuable insights for patients, allowing them to assess their rehabilitation progress and distinguish between different levels of gait recovery. The proposed markerless approach demonstrates acceptable accuracy in measuring knee joint angles during a sagittal walk and provides a reliable rehabilitation score, making it a convenient and cost-effective alternative for automatic at-home rehabilitation monitoring

    Anterior Abdominal Wall Endometriosis Following Caesarean Section: Two Rare Cases

    Get PDF
    Parietal endometriosis is a rare clinical entity, whose pathophysiology remains unclear. It occurs most often after gynecological or obstetrical surgery. The clinical picture is relatively unspecific. Medical imaging is not very contributive. Only histological examination of the operative specimen can confirm the diagnosis. Surgical treatment must be wide enough to prevent recurrence. We report two cases of abdominal wall endometriosis occurring on caesarean section scar. Through these two cases, we will highlight the characteristics of this pathology including prognosis, which will help the practitioners in understanding the role of diagnosis and early management of this entity and its prevention during gynecological or obstetrical surgery
    corecore