2,394 research outputs found

    Graphene as Transparent Electrode for Direct Observation of Hole Photoemission from Silicon to Oxide

    Full text link
    The outstanding electrical and optical properties of graphene make it an excellent alternative as a transparent electrode. Here we demonstrate the application of graphene as collector material in internal photoemission (IPE) spectroscopy; enabling the direct observation of both electron and hole injections at a Si/Al2O3 interface and successfully overcoming the long-standing difficulty of detecting holes injected from a semiconductor emitter in IPE measurements. The observed electron and hole barrier heights are 3.5 eV and 4.1 eV, respectively. Thus the bandgap of Al2O3 can be further deduced to be 6.5 eV, in close agreement with the valued obtained by vacuum ultraviolet spectroscopic ellipsometry analysis. The detailed optical modeling of a graphene/Al2O3/Si stack reveals that by using graphene in IPE measurements the carrier injection from the emitter is significantly enhanced and the contribution of carrier injection from the collector electrode is minimal. The method can be readily extended to various IPE test structures for a complete band alignment analysis and interface characterization.Comment: 15 pages, 5 figure

    Matter-gravity couplings and Lorentz violation

    Get PDF
    The gravitational couplings of matter are studied in the presence of Lorentz and CPT violation. At leading order in the coefficients for Lorentz violation, the relativistic quantum hamiltonian is derived from the gravitationally coupled minimal Standard-Model Extension. For spin-independent effects, the nonrelativistic quantum hamiltonian and the classical dynamics for test and source bodies are obtained. A systematic perturbative method is developed to treat small metric and coefficient fluctuations about a Lorentz-violating and Minkowski background. The post-newtonian metric and the trajectory of a test body freely falling under gravity in the presence of Lorentz violation are established. An illustrative example is presented for a bumblebee model. The general methodology is used to identify observable signals of Lorentz and CPT violation in a variety of gravitational experiments and observations, including gravimeter measurements, laboratory and satellite tests of the weak equivalence principle, antimatter studies, solar-system observations, and investigations of the gravitational properties of light. Numerous sensitivities to coefficients for Lorentz violation can be achieved in existing or near-future experiments at the level of parts in 10^3 down to parts in 10^{15}. Certain coefficients are uniquely detectable in gravitational searches and remain unmeasured to date.Comment: 59 pages two-column REVTe

    Bound on Lorentz- and CPT-Violating Boost Effects for the Neutron

    Get PDF
    A search for an annual variation of a daily sidereal modulation of the frequency difference between co-located 129{}^{129}Xe and 3{}^{3}He Zeeman masers sets a stringent limit on boost-dependent Lorentz and CPT violation involving the neutron, consistent with no effect at the level of 150 nHz. In the framework of the general Standard-Model Extension, the present result provides the first clean test for the fermion sector of the symmetry of spacetime under boost transformations at a level of 102710^{-27} GeV.Comment: 4 pages, 1 figur

    Relationship between serum testosterone and fracture risk in men: a comparison of RIA and LC-MS/MS

    Get PDF
    BACKGROUND: Serum testosterone can be measured byLC-MS/MS and RIA. We investigated whether the testosterone–fracture relationship was affected by the method of measurement. METHODS: We measured total testosterone (TT) by LCMS/MS (TTLC-MS/MS) and RIA (TTRIA) in serum samples collected from 602 men whose incident fractures had been continuously ascertained by x-ray reports from 1989 to 2010. We measured bone mineral density (BMD) by dual-energy x-ray absorptiometry. The association between TT and fracture risk was assessed by the Cox proportional hazards model, taking into account the effect of age and BMD. CONCLUSIONS: The concordance between LC-MS/MS and RIA in the measurement of serum TT was moderate. Moreover, the magnitude of association between testosterone and fracture risk in older men was largely unaffected by the method of measurement. © 2015 American Association for Clinical Chemistr

    Signals for Lorentz Violation in Post-Newtonian Gravity

    Get PDF
    The pure-gravity sector of the minimal Standard-Model Extension is studied in the limit of Riemann spacetime. A method is developed to extract the modified Einstein field equations in the limit of small metric fluctuations about the Minkowski vacuum, while allowing for the dynamics of the 20 independent coefficients for Lorentz violation. The linearized effective equations are solved to obtain the post-newtonian metric. The corresponding post-newtonian behavior of a perfect fluid is studied and applied to the gravitating many-body system. Illustrative examples of the methodology are provided using bumblebee models. The implications of the general theoretical results are studied for a variety of existing and proposed gravitational experiments, including lunar and satellite laser ranging, laboratory experiments with gravimeters and torsion pendula, measurements of the spin precession of orbiting gyroscopes, timing studies of signals from binary pulsars, and the classic tests involving the perihelion precession and the time delay of light. For each type of experiment considered, estimates of the attainable sensitivities are provided. Numerous effects of local Lorentz violation can be studied in existing or near-future experiments at sensitivities ranging from parts in 10^4 down to parts in 10^{15}.Comment: 46 pages two-column REVTeX, accepted in Physical Review

    Monitoring for Plasmodium falciparum drug resistance to artemisinin and artesunate in Binh Phuoc Province, Vietnam: 1998-2009

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Artemisinin derivatives have been used for malaria treatment in Vietnam since 1989. Reported malaria cases have decreased from 1,672,000 with 4,650 deaths in 1991, to 91,635 with 43 deaths in 2006. Current national guidelines recommend artemisinin-based combination therapy (ACT), although artesunate is still available as monotherapy through the private sector. Recent reports suggest that effectiveness of ACT and artesunate monotherapy has declined in western Cambodia. This study examined <it>Plasmodium falciparum </it>resistance patterns over 10 years in southwest Vietnam in infected patients treated with artemisinin compounds.</p> <p>Methods</p> <p>The study was conducted in two communes in Phuoc Long district, Binh Phuoc province, 100 km west of the Cambodian border. This was chosen as a likely site for emerging artemisinin resistance because of the high prevalence of <it>P. falciparum </it>malaria, and the length of time that artemisinin had been in use. In <it>vivo </it>and <it>in vitro </it>monitoring of <it>P. falciparum </it>susceptibility to anti-malarial drugs was conducted in 1998, 2001, 2004/5, and 2008/9. Patients with confirmed <it>P. falciparum </it>malaria received therapy with 5 or 7 days of artemisinin (1998 and 2001 respectively) or 7 days of artesunate</p> <p>Results</p> <p>In the four surveys, 270 patients were recruited and treated. The mean parasite clearance times differed between 1998, 2001 and 2004/5 (1.8, 2.3 and 2.1 days, P < 0.01) but not between 1998 and 2008/2009. The mean parasite clearance times were correlated with parasite density at day 0 (r = 0.4; P < 0.001). Treatment failure rates after PCR adjustment were 13.8%, 2.9%, 1.2%, and 0% respectively. Susceptibility of <it>P. falciparum </it>to artemisinin in <it>in vitro </it>tests was stable during the period, except for a rise in EC90 and EC99 in 2001.</p> <p>Conclusions</p> <p>This study showed stable levels of <it>P. falciparum </it>sensitivity to artemisinin compounds in the two sites over a ten-year period. The introduction of ACT in this area in 2003 may have protected against the development of artemisinin resistance. Adherence to the latest WHO and Vietnamese guidelines, which recommend ACT as first-line therapy in all malarious areas, and continued monitoring along the Vietnam-Cambodia border will be essential to prevent the spread of artemisinin resistance in Vietnam.</p

    Polyoxazoline-Based Bottlebrush and Brush-Arm Star Polymers via ROMP: Syntheses and Applications as Organic Radical Contrast Agents

    Get PDF
    Copyright © 2019 American Chemical Society. The synthesis of functional poly(2-alkyl-2-oxazoline) (PAOx) copolymers with complex nanoarchitectures using a graft-through ring-opening metathesis polymerization (ROMP) approach is described. First, well-defined norbornene-terminated poly(2-ethyl-2-oxazoline) (PEtOx) macromonomers (MM) were prepared by cationic ring-opening polymerization. ROMP of these MMs produced bottlebrush copolymers with PEtOx side chains. In addition, PEtOx-based branched MMs bearing a terminal alkyne group were prepared and conjugated to an azide-containing bis-spirocyclohexyl nitroxide via Cu-catalyzed azide-alkyne cycloaddition (CuAAC). ROMP of this branched MM, followed by in situ cross-linking, provided PEtOx-based brush-arm star polymers (BASPs) with nitroxide radicals localized at the core-shell interface. These PEtOx-based nitroxide-containing BASPs displayed relaxivity values on par with state-of-the-art polyethylene glycol (PEG)-based nitroxide materials, making them promising as organic radical contrast agents for metal-free magnetic resonance imaging (MRI)

    Right coronary wall cmr in the older asymptomatic advance cohort: positive remodeling and associations with type 2 diabetes and coronary calcium

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Coronary wall cardiovascular magnetic resonance (CMR) is a promising noninvasive approach to assess subclinical atherosclerosis, but data are limited in subjects over 60 years old, who are at increased risk. The purpose of the study was to evaluate coronary wall CMR in an asymptomatic older cohort.</p> <p>Results</p> <p>Cross-sectional images of the proximal right coronary artery (RCA) were acquired using spiral black-blood coronary CMR (0.7 mm resolution) in 223 older, community-based patients without a history of cardiovascular disease (age 60-72 years old, 38% female). Coronary measurements (total vessel area, lumen area, wall area, and wall thickness) had small intra- and inter-observer variabilities (r = 0.93~0.99, all p < 0.0001), though one-third of these older subjects had suboptimal image quality. Increased coronary wall thickness correlated with increased coronary vessel area (p < 0.0001), consistent with positive remodeling. On multivariate analysis, type 2 diabetes was the only risk factor associated with increased coronary wall area and thickness (p = 0.03 and p = 0.007, respectively). Coronary wall CMR measures were also associated with coronary calcification (p = 0.01-0.03).</p> <p>Conclusions</p> <p>Right coronary wall CMR in asymptomatic older subjects showed increased coronary atherosclerosis in subjects with type 2 diabetes as well as coronary calcification. Coronary wall CMR may contribute to the noninvasive assessment of subclinical coronary atherosclerosis in older, at-risk patient groups.</p

    Minimum information and guidelines for reporting a Multiplexed Assay of Variant Effect

    Full text link
    Multiplexed Assays of Variant Effect (MAVEs) have emerged as a powerful approach for interrogating thousands of genetic variants in a single experiment. The flexibility and widespread adoption of these techniques across diverse disciplines has led to a heterogeneous mix of data formats and descriptions, which complicates the downstream use of the resulting datasets. To address these issues and promote reproducibility and reuse of MAVE data, we define a set of minimum information standards for MAVE data and metadata and outline a controlled vocabulary aligned with established biomedical ontologies for describing these experimental designs
    corecore