7 research outputs found

    Biomarkers of myocardial injury with different energy sources for atrial fibrillation catheter ablation

    Get PDF
    Background: Our study aims to compare acute myocardial injury biomarker rise after atrial fibrillation ablation performed with different technologies.Methods and Results: One hundred and ten patients were treated with pulmonary vein isolation with 4 different technologies: open-irrigated tip radiofrequency (RF) catheter in35 patients (Group A), cryoballoon in 35 patients (Group B), visually guided laser balloon in 20 patients (Group C), open-irrigated tip RF catheter with contact-force-sensing technology in 20 patients (Group D). Post-procedure samples of cardiac troponin I (cTnI) and creatinine kinase-MB (CK-MB) were collected at 19 ± 3 h and 43 ± 3 h after ablation. At the first postprocedural sample, cTnI and CK-MB levels were found elevated in all 110 patients with a median value of 2.11 ng/mL and 8.95 ng/mL, respectively. Group B showed cTnI levels increased (median 5.96 ng/mL) compared to other groups (median Group A: 1.72 ng/mL, Group C: 1.54 ng/mL, Group D: 2.0 ng/mL; p < 0.001). Also CK-MB levels resulted higher in cryoablation (median 26.4 ng/mL) compared to other groups (median Group A: 6.40 ng/mL, Group C: 7.15 ng/mL, Group D: 6.50 ng/mL; p < 0.001). No significant association was observed between biomarker levels and recurrences of atrial fibrillation after a mean follow-up of 369 ± 196 days.Conclusions: Highest markers for myocardial injury were observed in the cryoballoon group. It is possible that a longer delivery energy duration and other factors affecting lesion size resulted in higher amount of cardiac injury in cryoablation. The higher levels of cardiac biomarkers did not translate into a better outcome and its physiologic significance is unknown.

    Feasibility and safety of catheter ablation of electrical storm in ischemic dilated cardiomyopathy

    No full text
    Electrical storm is an emergency in 'implantation of a cardioverter defibrillator' carriers with ischemic dilated cardiomyopathy (DCM) and negatively impacts long-term prognosis. We evaluated the feasibility, safety, and effectiveness of radiofrequency catheter ablation (RFCA) in controlling electrical storm and its impact on survival and ventricular tachycardia/fibrillation recurrence

    The growing culture of a minimally fluoroscopic approach in electrophysiology lab

    Get PDF
    Abstract Most of interventional procedures in cardiology are carried out under fluoroscopic imaging guidance. Besides other peri-interventional risks, radiation exposure should be considered for its stochastic (inducing malignancy) and deterministic effects on health (tissue reactions like erythema, hair loss and cataracts). In this article we analized the radiation risk from cardiovascular imaging to both patients and medical staff and discusses how customize the X-ray system and how to implement shielding measures in the cath lab. Finally, we reviewed the most recent developments and the latest findings in catheter navigation and 3D electronatomical mapping systems that may help to reduce patient and operator exposure
    corecore