374 research outputs found

    Simultaneous cyclization and derivatization of peptides using cyclopentenediones

    Get PDF
    Unprotected linear peptides containing N-terminal cysteines and another cysteine residue can be simultaneously cyclized and derivatized using 2,2-disubstituted cyclopentenediones. High yields of cyclic peptide conjugates may be obtained in short reaction times using only a slight excess of the cyclopentenedione moiety under TEMPO catalysis and in the presence of LiCl

    Plan moderno de asistencia a los alienados (1926).

    Get PDF
    Asistencia premanicomial de los alienados. Asistencia manicomial de los alienados. Manicomios de agudos. Manicomios de crónicos. Asistencia postmanicomial de los alienados

    β-decay half-lives and β-delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N = 126

    Get PDF
    Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8 He up to 150La. Apart from 210Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150. Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126, in order to guide theoretical models and help understand the formation of the third r-process peak at A ∼ 195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126. Method: Ions of interest were produced by fragmentation of a 238U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3 He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204−206Au, 208–211Hg, 211–216Tl, 215–218Pb, and 218–220Bi, nine of them for the first time. Neutron emission probabilities are reported for 210,211Hg and 211–216Tl. Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. The measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).Spanish Ministerio de Economía y Competitividad-FPA2011- 28770-C03-03, FPA2008-04972-C03-3, AIC-D2011-0705, FPA2011-24553, FPA2008-6419, FPA2010-17142, FPA2014-52823-C2-1-P, FPA2014- 52823-C2-2-P, and CPAN CSD-2007-00042 (Ingenio2010)Program Severo Ochoa-SEV-2014-0398German Helmholtz Association (Young Investigators)-VH-NG 627 (LISA-Lifetime Spectroscopy for Astrophysics)Nuclear Astrophysics Virtual Institute-VH-VI-417German Bundesministerium für Bildung und Forschung-06MT7178 / 05P12WOFNFSpanish Nuclear Security Council (CSN)-Catedra ArgosUK Science & Technology Facilities Council (STFC)-ST/F012012/

    Plan moderno de asistencia a los alienados (1926).

    Get PDF
    Asistencia premanicomial de los alienados. Asistencia manicomial de los alienados. Manicomios de agudos. Manicomios de crónicos. Asistencia postmanicomial de los alienados

    Experimental study of Tc 100 β decay with total absorption γ -ray spectroscopy

    Get PDF
    The β decay of Tc100 has been studied by using the total absorption γ-ray spectroscopy technique at the Ion Guide Isotope Separator On-Line facility in Jyväskylä. In this work the new Decay Total Absorption γ-ray Spectrometer in coincidence with a cylindrical plastic β detector has been employed. The β intensity to the ground state obtained from the analysis is in good agreement with previous high-resolution measurements. However, differences in the feeding to the first-excited state as well as weak feeding to a new level at high excitation energy have been deduced from this experiment. Theoretical calculations performed in the quasiparticle random-phase approximation framework are also reported. Comparison of these calculations with our measurement serves as a benchmark for calculations of the double β decay of Mo100. © 2017 American Physical Society

    A validation study comparing self-reported travel diaries and objective data obtained from in-vehicle monitoring devices in older drivers with bilateral cataract

    Get PDF
    Background: Advances in technology have made it possible to examine real-world driving using naturalistic data obtained from in-vehicle monitoring devices. These devices overcome the weaknesses of self-report methods and can provide comprehensive insights into driving exposure, habits and practices of older drivers. Aim: The aim of this study is to compare self-reported and objectively measured driving exposure, habits and practices using a travel diary and an in-vehicle driver monitoring device in older drivers with bilateral cataract. Methods: A cross-sectional study was undertaken. Forty seven participants aged 58-89 years old (mean. =74.1; S.D. =7.73) were recruited from three eye clinics over a one year period. Data collection consisted of a cognitive test, a researcher-administered questionnaire, a travel diary and an in-vehicle monitoring device. Participants' driving exposure and patterns were recorded for one week using in-vehicle monitoring devices. They also completed a travel diary each time they drove a motor vehicle as the driver. Paired t-tests were used to examine differences/agreement between the two instruments under different driving circumstances. Results: The data from the older drivers' travel diaries significantly underestimated the number of overall trips (p < 0.001), weekend trips (p. =0.002) and trips during peak hour (p. =0.004). The travel diaries also significantly overestimated overall driving duration (p. &lt;. 0.001) and weekend driving duration (p. =0.003), compared to the data obtained from the in-vehicle monitoring devices. No significant differences were found between instruments for kilometres travelled under any of the driving circumstances.Conclusions: The results of this study found that relying solely on self-reported travel diaries to assess driving outcomes may not be accurate, particularly for estimates of the number of trips made and duration of trips. The clear advantages of using in-vehicle monitoring devices over travel diaries to monitor driving habits and exposure among an older population are evident

    First tests of the applicability of γ\gamma-ray imaging for background discrimination in time-of-flight neutron capture measurements

    Full text link
    In this work we explore for the first time the applicability of using γ\gamma-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr3_3 scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a 197^{197}Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.Comment: Preprint submitted to Nucl. Instr. and Meth.

    Simultaneous cyclization and derivatization of peptides using cyclopentenediones

    Get PDF
    Unprotected linear peptides containing N-terminal cysteines and another cysteine residue can be simultaneously cyclized and derivatized using 2,2-disubstituted cyclopentenediones. High yields of cyclic peptide conjugates may be obtained in short reaction times using only a slight excess of the cyclopentenedione moiety under TEMPO catalysis and in the presence of LiCl
    • …
    corecore