50 research outputs found

    An Affordable Bio-Sensing and Activity Tagging Platform for HCI Research

    Full text link
    We present a novel multi-modal bio-sensing platform capable of integrating multiple data streams for use in real-time applications. The system is composed of a central compute module and a companion headset. The compute node collects, time-stamps and transmits the data while also providing an interface for a wide range of sensors including electroencephalogram, photoplethysmogram, electrocardiogram, and eye gaze among others. The companion headset contains the gaze tracking cameras. By integrating many of the measurements systems into an accessible package, we are able to explore previously unanswerable questions ranging from open-environment interactions to emotional response studies. Though some of the integrated sensors are designed from the ground-up to fit into a compact form factor, we validate the accuracy of the sensors and find that they perform similarly to, and in some cases better than, alternatives

    Effects of Supervised Exercise-based Telerehabilitation on Walk Test Performance and Quality of Life in Patients in India with Chronic Disease: Combatting COVID-19

    Get PDF
    Background: The world is currently undergoing a pandemic, caused by the SARS-CoV-2 virus (COVID-19). According to the World Health Organization, patients with chronic illnesses appear to be at the highest risk for COVID-19 associated sequelae. Inability to participate in outpatient-based rehabilitation programs and being home-bound can increase the risk for and potential worsening of chronic health conditions. This study evaluated the short-term effects of telerehabilitation on patients’ walk test performance and health related quality of life (HRQoL).  Methods: 47 patients (23 cardiovascular, 15 pulmonary, 9 oncology) participated in the telerehabilitation program. At baseline and following a 1-month intervention, patients had their 6-minute walk test distance (6MWTD) and HRQoL assessed. Average daily step counts were measured by the PACER App. Conclusion: Our results indicate that a short-term, supervised virtual telerehabilitation program had significant positive effects on 6MWTD and HRQoL in cardiac, pulmonary and oncology patients during COVID-19

    Transgluteal CT-Guided Percutaneous Renal Access for Percutaneous Nephrolithotomy in a Pelvic Horseshoe Kidney

    Get PDF
    CT-guided percutaneous renal access has been described as a safe and effective access technique in patients with complex anatomy, including ectopic kidney, retrorenal colon, spinal dysraphism, hepatomegaly, and splenomegaly. In comparison to conventional intraoperative fluoroscopic-guided access, CT imaging allows for delineation of surrounding structures that are at risk for injury during percutaneous access. However, previous reports indicate that pelvic kidneys might be inaccessible percutaneously without laparoscopic assistance. Herein, we present a novel transgluteal route to renal access for percutaneous nephrolithotomy (PCNL) in a patient with a pelvic horseshoe kidney and severe spinal deformity

    Contrast-Enhanced Ultrasound Versus Doppler Ultrasound for Detection of Early Vascular Complications of Pancreas Grafts

    Get PDF
    OBJECTIVE. The purpose of this study is to compare conventional duplex ultrasound and contrast-enhanced ultrasound (CEUS) for identifying vascular abnormalities in pancreas allografts in the immediate posttransplant setting. Identification of pancreas allografts at risk of failure may impact patient care because early intervention for vascular insufficiency can lead to graft salvage. MATERIALS AND METHODS. Two radiologists who were blinded to patient outcomes performed a retrospective analysis of the postoperative Doppler ultrasound and CEUS images of 34 pancreas grafts from transplants performed between 2017 and 2019. A total of 28 patients who did not require surgical reexploration were considered the control group. Six patients had surgically proven arterial or venous abnormalities on surgical reexploration. Each radiologist scored grafts as having normal or abnormal vascularity on the basis of image sets obtained using Doppler ultrasound only and CEUS only. Comparisons of both the diagnostic performance of each modality and interobserver agreement were performed. RESULTS. Both readers showed that CEUS had increased sensitivity for detecting vascular abnormalities (83.3% for both readers) compared with Doppler ultrasound (66.7% and 50.0%). For both readers, the specificity of CEUS was similar to that of Doppler imaging (81.6% and 78.9% for reader 1 and reader 2 versus 76.3% and 84.2% for reader 1 and reader 2). For both readers, the negative predictive value of CEUS was higher than that of Doppler ultrasound (96.9% and 96.8% for reader 1 and reader 2 versus 93.5% and 91.4% for reader 1 and reader 2). Interobserver agreement was higher for CEUS than for Doppler ultrasound (κ = 0.54 vs κ = 0.28). CONCLUSION. CEUS may provide radiologists and surgeons with a means of timely and effective evaluation of pancreas graft perfusion after surgery, and it may help identify grafts that could benefit from surgical salvage

    Pancreatic cystic neoplasms and post-inflammatory cysts: interobserver agreement and diagnostic performance of MRI with MRCP

    Get PDF
    Purpose: We aimed to answer several clinically relevant questions; (1) the interobserver agreement, (2) diagnostic performance of MRI with MRCP for (a) branch duct intraductal papillary mucinous neoplasms (BD-IPMN), mucinous cystic neoplasms (MCN) and serous cystic neoplasms (SCN), (b) distinguishing mucinous (BD-IPMN and MCN) from non-mucinous cysts, and (c) distinguishing three pancreatic cystic neoplasms (PCN) from post-inflammatory cysts (PIC). Methods: A retrospective analysis was performed at a tertiary referral center for pancreatic diseases on 71 patients including 44 PCNs and 27 PICs. All PCNs were confirmed by surgical pathology to be 17 BD-IPMNs, 13 MCNs, and 14 SCNs. Main duct and mixed type IPMNs were excluded. Two experienced abdominal radiologists blindly reviewed all the images. Results: Sensitivity of two radiologists for BD-IPMN, MCN and SCN was 88-94%, 62-69% and 57-64%, specificity of 67-78%, 67-78% and 67-78%, and accuracy of 77-82%, 65-75% and 63-73%, respectively. There was 80% sensitivity, 63-73% specificity, 70-76% accuracy for distinguishing mucinous from non-mucinous neoplasms, and 73-75% sensitivity, 67-78% specificity, 70-76% accuracy for distinguishing all PCNs from PICs. There was moderate-to-substantial interobserver agreement (Cohen's kappa: 0.65). Conclusion: Two experienced abdominal radiologists had moderate-to-high sensitivity, specificity, and accuracy for BD-IPMN, MCN, and SCN. The interobserver agreement was moderate-to-substantial. MRI with MRCP can help workup of incidental pancreatic cysts by distinguishing PCNs from PICs, and premalignant mucinous neoplasms from cysts with no malignant potential

    Biomechanical Material Characterization of Stanford Type-B Dissected Porcine Aortas

    Get PDF
    Aortic dissection (AD) involves tearing of the medial layer, creating a blood-filled channel called false lumen (FL). To treat dissections, clinicians are using endovascular therapy using stent grafts to seal the FL. This procedure has been successful in reducing mortality but has failed in completely re-attaching the torn intimal layer. The use of computational analysis can predict the radial forces needed to devise stents that can treat ADs. To quantify the hyperelastic material behavior for therapy development, we harvested FL wall, true lumen (TL) wall, and intimal flap from the middle and distal part of five dissected aortas. Planar biaxial testing using multiple stretch protocols were conducted on tissue samples to quantify their deformation behavior. A novel non-linear regression model was used to fit data against Holzapfel–Gasser–Ogden hyperelastic strain energy function. The fitting analysis correlated the behavior of the FL and TL walls and the intimal flap to the stiffness observed during tensile loading. It was hypothesized that there is a variability in the stresses generated during loading among tissue specimens derived from different regions of the dissected aorta and hence, one should use region-specific material models when simulating type-B AD. From the data on material behavior analysis, the variability in the tissue specimens harvested from pigs was tabulated using stress and coefficient of variation (CV). The material response curves also compared the changes in compliance observed in the FL wall, TL wall, and intimal flap for middle and distal regions of the dissection. It was observed that for small stretch ratios, all the tissue specimens behaved isotropically with overlapping stress–stretch curves in both circumferential and axial directions. As the stretch ratios increased, we observed that most tissue specimens displayed different structural behaviors in axial and circumferential directions. This observation was very apparent in tissue specimens from mid FL region, less apparent in mid TL, distal FL, and distal flap tissues and least noticeable in tissue specimens harvested from mid flap. Lastly, using mixed model ANOVAS, it was concluded that there were significant differences between mid and distal regions along axial direction which were absent in the circumferential direction

    Global, regional, and national burden of colorectal cancer and its risk factors, 1990–2019: a systematic analysis for the Global Burden of Disease Study 2019

    Get PDF
    Funding: F Carvalho and E Fernandes acknowledge support from Fundação para a Ciência e a Tecnologia, I.P. (FCT), in the scope of the project UIDP/04378/2020 and UIDB/04378/2020 of the Research Unit on Applied Molecular Biosciences UCIBIO and the project LA/P/0140/2020 of the Associate Laboratory Institute for Health and Bioeconomy i4HB; FCT/MCTES through the project UIDB/50006/2020. J Conde acknowledges the European Research Council Starting Grant (ERC-StG-2019-848325). V M Costa acknowledges the grant SFRH/BHD/110001/2015, received by Portuguese national funds through Fundação para a Ciência e Tecnologia (FCT), IP, under the Norma Transitória DL57/2016/CP1334/CT0006.proofepub_ahead_of_prin
    corecore