876 research outputs found

    Castor Roots In A Vertic Inceptisol

    Get PDF
    The root systems of 4 large and 4 small, mature castor (Ricinus communis) cv. Acuna plants were excavated. Large and small plants had similar root:shoot ratios but roots of small plants were longer per unit weight. Soil factors in or near the surface of the C1 horizon, probably higher gravel and carbonate content, apparently restricted root penetration

    Assessment of MRI issues at 3-Tesla for metallic surgical implants: findings applied to 61 additional skin closure staples and vessel ligation clips

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>Metallic skin closure staples and vessel ligation clips should be tested at 3-Tesla to characterize MRI issues in order to ensure patient safety. Therefore, metallic surgical implants were assessed at 3-Tesla for magnetic field interactions, MRI-related heating, and artifacts.</p> <p>Methods</p> <p>A skin closure staple (Visistat Skin Stapler, staple, Polytetrafluoroethylene, PTFE, coated 316L/316LVM stainless steel; Teleflex Medical, Durham, NC) and a vessel ligation clip (Hemoclip Traditional, stainless steel; Teleflex Medical, Durham, NC) that represented the largest metallic sizes made from materials with the highest magnetic susceptibilities (i.e., based on material information) among 61 other surgical implants (52 metallic implants, 9 nonmetallic implants) underwent evaluation for magnetic field interactions, MRI-related heating, and artifacts using standardized techniques. MRI-related heating was assessed by placing each implant in a gelled-saline-filled phantom with MRI performed using a transmit/receive RF body coil at an MR system reported, whole body averaged SAR of 2.9-W/kg for 15-min. Artifacts were characterized using T1-weighted, SE and GRE pulse sequences.</p> <p>Results</p> <p>Each surgical implant showed minor magnetic field interactions (20- and 27-degrees, which is acceptable from a safety consideration). Heating was not substantial (highest temperature change, ā‰¤ 1.6Ā°C). Artifacts may create issues if the area of interest is in the same area or close to the respective surgical implant.</p> <p>Conclusions</p> <p>The results demonstrated that it would be acceptable for patients with these metallic surgical implants to undergo MRI at 3-Tesla or less. Because of the materials and dimensions of the surgical implants that underwent testing, these findings pertain to 61 additional similar implants.</p

    Development of a composite prototype with GFRP profiles and sandwich panels used as a floor module of an emergency house

    Get PDF
    A series of experimental tests carried out on a composite prototype to be used as a floor module of an emergency house is presented in this paper. The prototype comprises a frame structure formed by GFRP pultruded profiles, and two sandwich panels constituted by GFRP skins and a polyurethane foam core that configures the floor slab. The present work is part of the project ā€œClickHouse ā€“ Development of a prefabricated emergency house prototype made of composites materialsā€ and investigates the feasibility of the assemblage process of the prototype and performance to support load conditions typical of residential houses. Furthermore, sandwich panels are also independently tested, analysing their flexural response, failure mechanisms and creep behaviour. Obtained results confirm the good performance of the prototype to be used as floor module of an emergency housing, with a good mechanical behaviour and the capacity of being transported to the disaster areas in the form of various low weight segments, and rapidly installed. Additionally, finite element simulations were carried out to assess the stress distributions in the prototype components and to evaluate the global behaviour and load transfer mechanism of the connections.Quadro de ReferĆŖncia EstratĆ©gica Nacional (QREN)FEDER funds through the Operational Program for Competitiveness Factors ā€“ COMPETE and the Portuguese National Agency of Innovation (ADI) - project no. 3896

    Flexural performance of innovative hybrid sandwich panels with special focus on the shear connection behavior

    Get PDF
    The present study intends to evaluate the flexural performance of hybrid sandwich panels through the execution of four point bending tests. The proposed hybrid sandwich panel uses Deflection Hardening Cementitious Composites (DHCC) on the top layer, a GFRP bottom layer and perforated shear connectors in the GFRP ribs to transfer shear stresses between top and bottom layers. The tested hybrid slabs use two types of shear connectors, which include indented and perforated shapes. The tests were performed to study the behaviour of a novel shear connection between the GFRP ribs and the DHCC layer that is here proposed. A comparison on the obtained experimental results was executed to clarify the influence of the shear connectorsā€™ geometries on the flexural performance of the developed hybrid slabs. The results show that the shear connection mechanical behaviour strongly influences the peak load, the deflection at peak load, the post-peak load carrying capacity and the degree of composite action of the hybrid slabs.The study presented in this paper is a part of the research project "RehabGFRP - Rehabilitation of Building Floors with Lightweight High Performance GFRP Sandwich Panels", with reference number of PTDC/ECM/113041/2009. Furthermore, the authors honestly appreciate the collaboration of the following labs: Civitest for developing DHCC materials (Eng. Delfina Goncalves), PIEP for conducting VARTM process (Eng. Luis Oliveira) and Department of Civil Engineering of Minho University to perform the tests (Mr. Antonio Matos and Eng. Marco Jorge).info:eu-repo/semantics/publishedVersio

    Caenorhabditis elegans: An Emerging Model in Biomedical and Environmental Toxicology

    Get PDF
    The nematode Caenorhabditis elegans has emerged as an important animal model in various fields including neurobiology, developmental biology, and genetics. Characteristics of this animal model that have contributed to its success include its genetic manipulability, invariant and fully described developmental program, well-characterized genome, ease of maintenance, short and prolific life cycle, and small body size. These same features have led to an increasing use of C. elegans in toxicology, both for mechanistic studies and high-throughput screening approaches. We describe some of the research that has been carried out in the areas of neurotoxicology, genetic toxicology, and environmental toxicology, as well as high-throughput experiments with C. elegans including genome-wide screening for molecular targets of toxicity and rapid toxicity assessment for new chemicals. We argue for an increased role for C. elegans in complementing other model systems in toxicological research
    • ā€¦
    corecore