110 research outputs found

    Using the Oxford cognitive screen to detect cognitive impairment in stroke patients. A comparison with the Mini-Mental State Examination

    Get PDF
    Background: The Oxford Cognitive Screen (OCS) was recently developed with the aim of describing the cognitive de cits after stroke. The scale consists of 10 tasks encom- passing ve cognitive domains: attention and executive function, language, memory, number processing, and praxis. OCS was devised to be inclusive and un-confounded by aphasia and neglect. As such, it may have a greater potential to be informative on stroke cognitive de cits of widely used instruments, such as the Mini-Mental State Examination (MMSE) or the Montreal Cognitive Assessment, which were originally devised for demented patients. Objective: The present study compared the OCS with the MMSE with regards to their ability to detect cognitive impairments post-stroke. We further aimed to examine perfor- mance on the OCS as a function of subtypes of cerebral infarction and clinical severity. Methods: 325 rst stroke patients were consecutively enrolled in the study over a 9-month period. The OCS and MMSE, as well as the Bamford classi cation and NIHSS, were given according to standard procedures. results: About a third of patients (35.3%) had a performance lower than the cutoff (<22) on the MMSE, whereas 91.6% were impaired in at least one OCS domain, indicating higher incidences of impairment for the OCS. More than 80% of patients showed an impairment in two or more cognitive domains of the OCS. Using the MMSE as a standard of clinical practice, the comparative sensitivity of OCS was 100%. Out of the 208 patients with normal MMSE performance 180 showed impaired performance in at least one domain of the OCS. The discrepancy between OCS and MMSE was particularly strong for patients with milder strokes. As for subtypes of cerebral infarction, fewer patients demonstrated widespread impairments in the OCS in the Posterior Circulation Infarcts category than in the other categories. conclusion: Overall, the results showed a much higher incidence of cognitive impairment with the OCS than with the MMSE and demonstrated no false negatives for OCS vs MMSE. It is concluded that OCS is a sensitive screen tool for cognitive de cits after stroke. In particular, the OCS detects high incidences of stroke-specific cognitive impairments, not detected by the MMSE, demonstrating the importance of cognitive pro ling.Background: The Oxford Cognitive Screen (OCS) was recently developed with the aim of describing the cognitive deficits after stroke. The scale consists of 10 tasks encompassing five cognitive domains: attention and executive function, language, memory, number processing, and praxis. OCS was devised to be inclusive and un-confounded by aphasia and neglect. As such, it may have a greater potential to be informative on stroke cognitive deficits of widely used instruments, such as the Mini-Mental State Examination (MMSE) or the Montreal Cognitive Assessment, which were originally devised for demented patients. Objective: The present study compared the OCS with the MMSE with regards to their ability to detect cognitive impairments post-stroke. We further aimed to examine performance on the OCS as a function of subtypes of cerebral infarction and clinical severity. Methods: 325 first stroke patients were consecutively enrolled in the study over a 9-month period. The OCS and MMSE, as well as the Bamford classification and NIHSS, were given according to standard procedures. Results: About a third of patients (35.3%) had a performance lower than the cutoff(< 22) on the MMSE, whereas 91.6% were impaired in at least one OCS domain, indicating higher incidences of impairment for the OCS. More than 80% of patients showed an impairment in two or more cognitive domains of the OCS. Using the MMSE as a standard of clinical practice, the comparative sensitivity of OCS was 100%. Out of the 208 patients with normal MMSE performance 180 showed impaired performance in at least one domain of the OCS. The discrepancy between OCS and MMSE was particularly strong for patients with milder strokes. As for subtypes of cerebral infarction, fewer patients demonstrated widespread impairments in the OCS in the Posterior Circulation Infarcts category than in the other categories. Conclusion: Overall, the results showed a much higher incidence of cognitive impairment with the OCS than with the MMSE and demonstrated no false negatives for OCS vs MMSE. It is concluded that OCS is a sensitive screen tool for cognitive deficits after stroke. In particular, the OCS detects high incidences of stroke-specific cognitive impairments, not detected by the MMSE, demonstrating the importance of cognitive profiling. © 2018 Mancuso, Demeyere, Abbruzzese, Damora, Varalta, Pirrotta, Antonucci, Matano, Caputo, Caruso, Pontiggia, Coccia, Ciancarelli, Zoccolotti and The Italian OCS Grou

    Lack of the Actin Capping Protein, Eps8, Affects NMDA-Type Glutamate Receptor Function and Composition

    Get PDF
    Actin-based remodeling underlines spine morphogenesis and plasticity and is crucially involved in the processes that constantly reshape the circuitry of the adult brain in response to external stimuli, leading to learning and memory formation and supporting cognitive functions. Hence spine morphology and synaptic strength are tightly linked and indeed abnormalities in spine number and morphology have been described in a number of neurological disorders such as autism spectrum disorders (ASDs), schizophrenia and intellectual disabilities. We have recently demonstrated that the actin regulating protein, Epidermal growth factor receptor pathway substrate 8 (Eps8), is essential for spine growth and long term potentiation. Indeed, mice lacking Eps8 display immature filopodia-like spines, which are unable to undergo potentiation, and are impaired in cognitive functions. Furthermore, reduced levels of Eps8 have been found in the brain of a cohort of patients affected by ASD compared to controls. Here we investigated whether the lack of Eps8, which is also part of the N-methyl-d-aspartate (NMDA) receptor complex, affects the functional maturation of the postsynaptic compartment. Our results demonstrate that Eps8 knock out mice (Eps8 KO) neurons display altered synaptic expression and subunit composition of NMDA receptors (i.e., increased GluN2B-, decreased GluN2A-containing receptors) and impaired GluN2B to GluN2A subunit shift. Indeed Eps8 KO neurons display increased content of GluN2B containing NMDA receptors both at the synaptic and extrasynaptic level. Furthermore, Eps8 KO neurons display an increased content of extra-synaptic GluN2B-containing receptors, suggesting that also the synaptic targeting of NMDA receptors is affected by the lack of Eps8. These data demonstrate that, besides regulation of spine morphogenesis, Eps8 also regulates the synaptic balance of NMDA receptors subunits GluN2A and GluN2B

    The Evolving Scenario in the Assessment of Radiological Response for Hepatocellular Carcinoma in the Era of Immunotherapy: Strengths and Weaknesses of Surrogate Endpoints

    Get PDF
    Hepatocellular carcinoma (HCC) is a challenging malignancy characterised by clinical and biological heterogeneity, independent of the stage. Despite the application of surveillance programs, a substantial proportion of patients are diagnosed at advanced stages when curative treatments are no longer available. The landscape of systemic therapies has been rapidly growing over the last decade, and the advent of immune-checkpoint inhibitors (ICIs) has changed the paradigm of systemic treatments. The coexistence of the tumour with underlying cirrhosis exposes patients with HCC to competing events related to tumour progression and/or hepatic decompensation. Therefore, it is relevant to adopt proper clinical endpoints to assess the extent of treatment benefit. While overall survival (OS) is the most accepted endpoint for phase III randomised controlled trials (RCTs) and drug approval, it is affected by many limitations. To overcome these limits, several clinical and radiological outcomes have been used. For instance, progression-free survival (PFS) is a useful endpoint to evaluate the benefit of sequential treatments, since it is not influenced by post-progression treatments, unlike OS. Moreover, radiological endpoints such as time to progression (TTP) and objective response rate (ORR) are frequently adopted. Nevertheless, the surrogacy between these endpoints and OS in the setting of unresectable HCC (uHCC) remains uncertain. Since most of the surrogate endpoints are radiology-based (e.g., PFS, TTP, ORR), the use of standardised tools is crucial for the evaluation of radiological response. The optimal way to assess the radiological response has been widely debated, and many criteria have been proposed over the years. Furthermore, none of the criteria have been validated for immunotherapy in advanced HCC. The coexistence of the underlying chronic liver disease and the access to several lines of treatments highlight the urgent need to capture early clinical benefit and the need for standardised radiological criteria to assess cancer response when using ICIs in mono- or combination therapies. Here, we review the most commonly used clinical and radiological endpoints for trial design, as well as their surrogacy with OS. We also review the criteria for radiological response to treatments for HCC, analysing the major issues and the potential future perspectives

    Epileptiform Activity and Cognitive Deficits in SNAP-25+/− Mice are Normalized by Antiepileptic Drugs

    Get PDF
    Synaptosomal-associated protein of 25 kDa (SNAP-25) is a protein that participates in the regulation of synaptic vesicle exocytosis through the formation of the soluble NSF attachment protein receptor complex and modulates voltage-gated calcium channels activity. The Snap25 gene has been associated with schizophrenia, attention deficit hyperactivity disorder, and bipolar disorder, and lower levels of SNAP-25 have been described in patients with schizophrenia. We used SNAP-25 heterozygous (SNAP-25+/−) mice to investigate at which extent the reduction of the protein levels affects neuronal network function and mouse behavior. As interactions of genotype with the specific laboratory conditions may impact behavioral results, the study was performed through a multilaboratory study in which behavioral tests were replicated in at least 2 of 3 distinct European laboratories. Reductions of SNAP-25 levels were associated with a moderate hyperactivity, which disappeared in the adult animals, and with impaired associative learning and memory. Electroencephalographic recordings revealed the occurrence of frequent spikes, suggesting a diffuse network hyperexcitability. Consistently, SNAP-25+/− mice displayed higher susceptibility to kainate-induced seizures, paralleled by degeneration of hilar neurons. Notably, both EEG profile and cognitive defects were improved by antiepileptic drugs. These results indicate that reduction of SNAP-25 expression is associated to generation of epileptiform discharges and cognitive dysfunctions, which can be effectively treated by antiepileptic drug

    Evaluation of Coaguchek®Pro II coagulation testing device performance to assess direct oral anticoagulant action. The DOAC-CHECK study

    Get PDF
    Direct oral anticoagulants (DOAC) measurement is recommended in specific conditions. A point-of-care testing should be used in emergency to qualitatively rule out relevant DOAC concentrations. The DOAC-CHECK Study aims to evaluate whether the use of CoaguChek® Pro II (Roche Diagnostics International Ltd, Rotkreuz, Switzerland) coagulation testing device can provide reliable information in patients treated with DOAC. The study was carried out in two FCSA (Italian Federation of Thrombosis Centers) centers. We choose 3 different concentration thresholds for our analysis (30, 50 and 100 ng/mL) and by ROC curves the ideal cut-off point was selected to be the one that yielded a sensitivity of at least 95% associated with the highest possible specificity. 512 patients were enrolled. For Edoxaban and Rivaroxaban, both CoaguChek® Pro II prothrombin time (PT) and activated partial thromboplastin time (aPTT) tests showed a sensitivity >95% corresponding to satisfying specificity values; negative predictive values resulted in the range 90-100%. At variance, CoaguChek® Pro II PT and aPTT tests did not seem to be useful for identifying Apixaban and Dabigatran concentrations higher than the pre-defined thresholds. Our results suggest that CoaguChek® Pro II coagulation testing device can be used to qualitatively identify relevant concentrations of Edoxaban or Rivaroxaban, but not of Apixaban or Dabigatran

    Nitrogen Concentration Estimation in Tomato Leaves by VIS-NIR Non-Destructive Spectroscopy

    Get PDF
    Nitrogen concentration in plants is normally determined by expensive and time consuming chemical analyses. As an alternative, chlorophyll meter readings and N-NO3 concentration determination in petiole sap were proposed, but these assays are not always satisfactory. Spectral reflectance values of tomato leaves obtained by visible-near infrared spectrophotometry are reported to be a powerful tool for the diagnosis of plant nutritional status. The aim of the study was to evaluate the possibility and the accuracy of the estimation of tomato leaf nitrogen concentration performed through a rapid, portable and non-destructive system, in comparison with chemical standard analyses, chlorophyll meter readings and N-NO3 concentration in petiole sap. Mean reflectance leaf values were compared to each reference chemical value by partial least squares chemometric multivariate methods. The correlation between predicted values from spectral reflectance analysis and the observed chemical values showed in the independent test highly significant correlation coefficient (r = 0.94). The utilization of the proposed system, increasing efficiency, allows better knowledge of nutritional status of tomato plants, with more detailed and sharp information and on wider areas. More detailed information both in space and time is an essential tool to increase and stabilize crop quality levels and to optimize the nutrient use efficiency
    corecore