21 research outputs found
Gender differences in the use of cardiovascular interventions in HIV-positive persons; the D:A:D Study
Peer reviewe
Blood transfer devices for malaria rapid diagnostic tests: evaluation of accuracy, safety and ease of use
<p>Abstract</p> <p>Background</p> <p>Malaria rapid diagnostic tests (RDTs) are increasingly used by remote health personnel with minimal training in laboratory techniques. RDTs must, therefore, be as simple, safe and reliable as possible. Transfer of blood from the patient to the RDT is critical to safety and accuracy, and poses a significant challenge to many users. Blood transfer devices were evaluated for accuracy and precision of volume transferred, safety and ease of use, to identify the most appropriate devices for use with RDTs in routine clinical care.</p> <p>Methods</p> <p>Five devices, a loop, straw-pipette, calibrated pipette, glass capillary tube, and a new inverted cup device, were evaluated in Nigeria, the Philippines and Uganda. The 227 participating health workers used each device to transfer blood from a simulated finger-prick site to filter paper. For each transfer, the number of attempts required to collect and deposit blood and any spilling of blood during transfer were recorded. Perceptions of ease of use and safety of each device were recorded for each participant. Blood volume transferred was calculated from the area of blood spots deposited on filter paper.</p> <p>Results</p> <p>The overall mean volumes transferred by devices differed significantly from the target volume of 5 microliters (p < 0.001). The inverted cup (4.6 microliters) most closely approximated the target volume. The glass capillary was excluded from volume analysis as the estimation method used is not compatible with this device. The calibrated pipette accounted for the largest proportion of blood exposures (23/225, 10%); exposures ranged from 2% to 6% for the other four devices. The inverted cup was considered easiest to use in blood collection (206/226, 91%); the straw-pipette and calibrated pipette were rated lowest (143/225 [64%] and 135/225 [60%] respectively). Overall, the inverted cup was the most preferred device (72%, 163/227), followed by the loop (61%, 138/227).</p> <p>Conclusions</p> <p>The performance of blood transfer devices varied in this evaluation of accuracy, blood safety, ease of use, and user preference. The inverted cup design achieved the highest overall performance, while the loop also performed well. These findings have relevance for any point-of-care diagnostics that require blood sampling.</p
Pediatr Nephrol
BACKGROUND: Hemolytic uremic syndrome related to Shiga-toxin-secreting Escherichia coli infection (STEC-HUS) remains a common cause of acute kidney injury in young children. No specific treatment has been validated for this severe disease. Recently, experimental studies highlight the potential role of complement in STEC-HUS pathophysiology. Eculizumab (EC), a monoclonal antibody against terminal complement complex, has been used in severe STEC-HUS patients, mostly during the 2011 German outbreak, with conflicting results. METHODS: On behalf of the French Society of Pediatric Nephrology, we retrospectively studied 33 children from 15 centers treated with EC for severe STEC-HUS. Indication for EC was neurologic involvement in 20 patients, cardiac and neurologic involvement in 8, cardiac involvement in 2, and digestive involvement in 3. Based on medical status at last follow-up, patients were divided into two groups: favorable (n = 15) and unfavorable outcomes (n = 18). RESULTS: Among patients with favorable outcome, 11/14 patients (79%) displayed persistent blockade of complement activity before each EC reinjection. Conversely, in patients with unfavorable outcome, only 9/15 (53%) had persistent blockade (p = n.s.). Among 28 patients presenting neurological symptoms, 19 had favorable neurological outcome including 17 with prompt recovery following first EC injection. Only two adverse effects potentially related to EC treatment were reported. CONCLUSIONS: Taken together, these results may support EC use in severe STEC-HUS patients, especially those presenting severe neurological symptoms. The study, however, is limited by absence of a control group and use of multiple therapeutic interventions in treatment groups. Thus, prospective, controlled trials should be undertaken