1,932 research outputs found
Nasal Carriage of Staphylococcus aureus and Antibiotic Susceptibility Pattern among Children in Freetown, Sierra Leone
Nasal carriage of Staphylococcus aureus has been demonstrated to be a major risk factor for invasive S. aureus infections in various population including children. The extent of S. aureus carriage in Sierra Leonean children is largely unknown. To determine the prevalence and pattern of antibiotic susceptibility of nasal S. aureus among children in Freetown, Sierra Leone, samples were collected from anterior nares of children less than two years at the Ola During Children’s Hospital between October 2008 and April 2009. Of the 116 children screened during the study period, S. aureus isolates were found in the nasal specimens of 40 (34.5%) of the children. Antimicrobial susceptibility testing to norfloxacin, gentamycin, erythromycin, trimethoprim-sulfamethazole, doxycycline, tetracycline and amoxycillin-clavulanic acid were observed to be 95, 35, 30, 20, 15, 7.5 and 2.5% respectively. All the isolates were susceptible to oxacillin and resistant to chloramphenicol, penicillin G, amoxycillin and ampiclox. Regular monitoring of antimicrobial susceptibility pattern may be useful.
Keywords: Antibiotic Susceptibility, Children, Nasal carriage, Staphylococcus aureu
A valley-spin qubit in a carbon nanotube
Although electron spins in III-V semiconductor quantum dots have shown great
promise as qubits, a major challenge is the unavoidable hyperfine decoherence
in these materials. In group IV semiconductors, the dominant nuclear species
are spinless, allowing for qubit coherence times that have been extended up to
seconds in diamond and silicon. Carbon nanotubes are a particularly attractive
host material, because the spin-orbit interaction with the valley degree of
freedom allows for electrical manipulation of the qubit. In this work, we
realise such a qubit in a nanotube double quantum dot. The qubit is encoded in
two valley-spin states, with coherent manipulation via electrically driven spin
resonance (EDSR) mediated by a bend in the nanotube. Readout is performed by
measuring the current in Pauli blockade. Arbitrary qubit rotations are
demonstrated, and the coherence time is measured via Hahn echo. Although the
measured decoherence time is only 65 ns in our current device, this work offers
the possibility of creating a qubit for which hyperfine interaction can be
virtually eliminated
Valley-spin blockade and spin resonance in carbon nanotubes
Manipulation and readout of spin qubits in quantum dots made in III-V
materials successfully rely on Pauli blockade that forbids transitions between
spin-triplet and spin-singlet states. Quantum dots in group IV materials have
the advantage of avoiding decoherence from the hyperfine interaction by
purifying them with only zero-spin nuclei. Complications of group IV materials
arise from the valley degeneracies in the electronic bandstructure. These lead
to complicated multiplet states even for two-electron quantum dots thereby
significantly weakening the selection rules for Pauli blockade. Only recently
have spin qubits been realized in silicon devices where the valley degeneracy
is lifted by strain and spatial confinement. In carbon nanotubes Pauli blockade
can be observed by lifting valley degeneracy through disorder. In clean
nanotubes, quantum dots have to be made ultra-small to obtain a large energy
difference between the relevant multiplet states. Here we report on
low-disorder nanotubes and demonstrate Pauli blockade based on both valley and
spin selection rules. We exploit the bandgap of the nanotube to obtain a large
level spacing and thereby a robust blockade. Single-electron spin resonance is
detected using the blockade.Comment: 31 pages including supplementary informatio
Paediatric radiology seen from Africa. Part I: providing diagnostic imaging to a young population
Article approval pendingPaediatric radiology requires dedicated equipment, specific precautions related to ionising radiation, and specialist knowledge. Developing countries face difficulties in providing adequate imaging services for children. In many African countries, children represent an increasing proportion of the population, and additional challenges follow from extreme living conditions, poverty, lack of parental care, and exposure to tuberculosis, HIV, pneumonia, diarrhoea and violent trauma. Imaging plays a critical role in the treatment of these children, but is expensive and difficult to provide. The World Health Organisation initiatives, of which the World Health Imaging System for Radiography (WHIS-RAD) unit is one result, needs to expand into other areas such as the provision of maintenance servicing. New initiatives by groups such as Rotary and the World Health Imaging Alliance to install WHIS-RAD units in developing countries and provide digital solutions, need support. Paediatric radiologists are needed to offer their services for reporting, consultation and quality assurance for free by way of teleradiology. Societies for paediatric radiology are needed to focus on providing a volunteer teleradiology reporting group, information on child safety for basic imaging, guidelines for investigations specific to the disease spectrum, and solutions for optimising imaging in children
Quality of anti-malarial drugs provided by public and private healthcare providers in south-east Nigeria
BACKGROUND: There is little existing knowledge about actual quality of drugs provided by different providers in Nigeria and in many sub-Saharan African countries. Such information is important for improving malaria treatment that will help in the development and implementation of actions designed to improve the quality of treatment. The objective of the study was to determine the quality of drugs used for the treatment of malaria in a broad spectrum of public and private healthcare providers. METHODS: The study was undertaken in six towns (three urban and three rural) in Anambra state, south-east Nigeria. Anti-malarials (225 samples), which included artesunate, dihydroartemisinin, sulphadoxine-pyrimethamine (SP), quinine, and chloroquine, were either purchased or collected from randomly selected providers. The quality of these drugs was assessed by laboratory analysis of the dissolution profile using published pharmacopoeial monograms and measuring the amount of active ingredient using high performance liquid chromatography (HPLC). FINDINGS: It was found that 60 (37%) of the anti-malarials tested did not meet the United States Pharmacopoeia (USP) specifications for the amount of active ingredients, with the suspect drugs either lacking the active ingredients or containing suboptimal quantities of the active ingredients. Quinine (46%) and SP formulations (39%) were among drugs that did not satisfy the tolerance limits published in USP monograms. A total of 78% of the suspect drugs were from private facilities, mostly low-level providers, such as patent medicine dealers (vendors). CONCLUSION: This study found that there was a high prevalence of poor quality drugs. The findings provide areas for public intervention to improve the quality of malaria treatment services. There should be enforced checks and regulation of drug supply management as well as stiffer penalties for people stocking substandard and counterfeit drugs
High energy emission from microquasars
The microquasar phenomenon is associated with the production of jets by X-ray
binaries and, as such, may be associated with the majority of such systems. In
this chapter we briefly outline the associations, definite, probable, possible,
and speculative, between such jets and X-ray, gamma-ray and particle emission.Comment: Contributing chapter to the book Cosmic Gamma-Ray Sources, K.S. Cheng
and G.E. Romero (eds.), to be published by Kluwer Academic Publishers,
Dordrecht, 2004. (19 pages
Distances and ages of globular clusters using Hipparcos parallaxes of local subdwarfs
We discuss the impact of Population II and Globular Cluster (GCs) stars on
the derivation of the age of the Universe, and on the study of the formation
and early evolution of galaxies, our own in particular. The long-standing
problem of the actual distance scale to Population II stars and GCs is
addressed, and a variety of different methods commonly used to derive distances
to Population II stars are briefly reviewed. Emphasis is given to the
discussion of distances and ages for GCs derived using Hipparcos parallaxes of
local subdwarfs. Results obtained by different authors are slightly different,
depending on different assumptions about metallicity scale, reddenings, and
corrections for undetected binaries. These and other uncertainties present in
the method are discussed. Finally, we outline progress expected in the near
future.Comment: Invited review article to appear in: `Post-Hipparcos Cosmic Candles',
A. Heck & F. Caputo (Eds), Kluwer Academic Publ., Dordrecht, in press. 22
pages including 3 tables and 2 postscript figures, uses Kluwer's crckapb.sty
LaTeX style file, enclose
Hybrid Mechanical Systems
We discuss hybrid systems in which a mechanical oscillator is coupled to
another (microscopic) quantum system, such as trapped atoms or ions,
solid-state spin qubits, or superconducting devices. We summarize and compare
different coupling schemes and describe first experimental implementations.
Hybrid mechanical systems enable new approaches to quantum control of
mechanical objects, precision sensing, and quantum information processing.Comment: To cite this review, please refer to the published book chapter (see
Journal-ref and DOI). This v2 corresponds to the published versio
- …