26 research outputs found

    Bright Flash Neutron Radiography at the McClellan Nuclear Research Reactor

    Get PDF
    AbstractThe University of California, Davis McClellan Nuclear Research Center (MNRC) operates a 2 MW TRIGATM reactor, which is currently the highest power TRIGATM reactor in the United States. The Center was originally build by the US Air Force to detect hidden defects in aircraft structures using neutron radiography; the Center can accommodate samples as large as 10.00 m long, 3.65 m high, and weighing up to 2,270kg.The MNRC reactor can be pulsed to 350 MW for about 30ms (FWHM). The combination of a short neutron pulse with a fast microchannel plate based neutron detector enables high-resolution flash neutron radiography to complement conventional neutron radiograph

    High-resolution detection system for time-of-flight electron spectrometry

    No full text
    One of the key components of a time-of-flight (TOF) spectrometer is the detection system. In addition to high timing resolution, accurate two-dimensional imaging substantially broadens the areas of applications of TOF spectrometers; for example, add a new dimension to angle-resolved photoemission spectroscopy (ARPES). In this paper we report on the recent developments of a high spatial (<50 mm) and timing (<130 ps) resolution imaging system capable of selective detection of electrons, ions and/or photons. Relative to our previously reported results, we have substantially improved the counting rate capabilities of the system especially for cases where the energy range of interest represents a small fraction of the incoming flux at the detector plane. The new system ignores all the events outside of a tunable time window substantially decreasing the dead time required for the event processing. That allows high-resolution TOF measurements within a given energy or momentum range and also can be used for distinguishing (or disabling) detection of photons versus detection of charged particles. The counting rate within a given energy window can be as high as ~;;400KHz at 10percent dead time. The electron detection system reported in the paper was developed for the TOF ARPES experiments at the Advanced Light Source, Lawrence Berkeley National Laboratory

    High-resolution detection system for time-of-flight electron spectrometry

    No full text
    One of the key components of a time-of-flight (TOF) spectrometer is the detection system. In addition to high timing resolution, accurate two-dimensional imaging substantially broadens the areas of applications of TOF spectrometers; for example, add a new dimension to angle-resolved photoemission spectroscopy (ARPES). In this paper we report on the recent developments of a high spatial (<50 mm) and timing (<130 ps) resolution imaging system capable of selective detection of electrons, ions and/or photons. Relative to our previously reported results, we have substantially improved the counting rate capabilities of the system especially for cases where the energy range of interest represents a small fraction of the incoming flux at the detector plane. The new system ignores all the events outside of a tunable time window substantially decreasing the dead time required for the event processing. That allows high-resolution TOF measurements within a given energy or momentum range and also can be used for distinguishing (or disabling) detection of photons versus detection of charged particles. The counting rate within a given energy window can be as high as ~;;400KHz at 10percent dead time. The electron detection system reported in the paper was developed for the TOF ARPES experiments at the Advanced Light Source, Lawrence Berkeley National Laboratory
    corecore