533 research outputs found

    Polyvinyl alcohol cross-linked with two aldehydes

    Get PDF
    A film forming polyvinyl alcohol resin is admixed, in aqueous solution, with a dialdehyde crosslinking agent which is capable of crosslinking the polyvinyl alcohol resin and a water soluble acid aldehyde containing a reactive aldehyde group capable of reacting with hydroxyl groups in the polyvinyl alcohol resin and an ionizable acid hydrogen atom. The dialdehyde is present in an amount sufficient to react with from 1 to 20% by weight of the theoretical amount required to react with all of the hydroxyl groups of the polyvinyl alcohol. The amount of acid aldehyde is from 1 to 50% by weight, same basis, and is sufficient to reduce the pH of the aqueous admixture to 5 or less. The admixture is then formed into a desired physical shape, such as by casting a sheet or film, and the shaped material is then heated to simultaneously dry and crosslink the article

    Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1

    Get PDF
    The new DIN (' Deutsche Industrie- Norm') 6875- 1, which is currently being finalised, deals with quality assurance ( QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/ radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4- mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in- house, the use of commercially available tools facilitated the QA according to the DIN 6875- 1 with which our results complied. Copyright (C) 2004 S. Karger AG, Basel

    Role of Tyk-2 in Th9 and Th17 cells in allergic asthma.

    Get PDF
    In a murine model of allergic asthma, we found that Tyk-2((-/-)) asthmatic mice have induced peribronchial collagen deposition, mucosal type mast cells in the lung, IRF4 and hyperproliferative lung Th2 CD4(+) effector T cells over-expressing IL-3, IL-4, IL-5, IL-10 and IL-13. We also observed increased Th9 cells expressing IL-9 and IL-10 as well as T helper cells expressing IL-6, IL-10 and IL-21 with a defect in IL-17A and IL-17F production. This T helper phenotype was accompanied by increased SOCS3 in the lung of Tyk-2 deficient asthmatic mice. Finally, in vivo treatment with rIL-17A inhibited local CD4(+)CD25(+)Foxp3(+) T regulatory cells as well as Th2 cytokines without affecting IL-9 in the lung. These results suggest a role of Tyk-2 in different subsets of T helper cells mediated by SOCS3 regulation that is relevant for the treatment of asthma, cancer and autoimmune diseases

    Evaluation of FISH for blood cultures under diagnostic real-life conditions

    Get PDF

    Induced Anticlinic Ordering and Nanophase Segregation of Bow-Shaped Molecules in a Smectic Solvent

    Full text link
    Recent experiments indicate that doping low concentrations of bent-core molecules into calamitic smectic solvents can induce anticlinic and biaxial smectic phases. We have carried out Monte Carlo (MC) simulations of mixtures of rodlike molecules (hard spherocylinders with length/breadth ratio Lrod/D=5L_{\rm rod}/D = 5) and bow- or banana-shaped molecules (hard spherocylinder dimers with length/breadth ratio Lban/D=5L_{ban}/D = 5 or 2.5 and opening angle ψ\psi) to probe the molecular-scale organization and phase behavior of rod/banana mixtures. We find that a low concentration (3%) of Lban/D=5L_{ban}/D = 5 dimers induces anticlinic (SmCA_A) ordering in an untilted smectic (SmA) phase for 100ψ<150100^\circ \le \psi < 150^\circ. For smaller ψ\psi, half of each bow-shaped molecule is nanophase segregated between smectic layers, and the smectic layers are untilted. For Lban/D=2.5L_{ban}/D = 2.5, no tilted phases are induced. However, with decreasing ψ\psi we observe a sharp transition from {\sl intralamellar} nanophase segregation (bow-shaped molecules segregated within smectic layers) to {\sl interlamellar} nanophase segregation (bow-shaped molecules concentrated between smectic layers) near ψ=130\psi = 130^\circ. These results demonstrate that purely entropic effects can lead to surprisingly complex behavior in rod/banana mixtures.Comment: 5 pages Revtex, 7 postscript figure

    IL-6 activated integrated BATF/IRF4 functions in lymphocytes are T-bet-independent and reversed by subcutaneous immunotherapy.

    Get PDF
    IL-6 plays a central role in supporting pathological TH2 and TH17 cell development and inhibiting the protective T regulatory cells in allergic asthma. TH17 cells have been demonstrated to regulate allergic asthma in general and T-bet-deficiency-induced asthma in particular. Here we found an inverse correlation between T-bet and Il-6 mRNA expression in asthmatic children. Moreover, experimental subcutaneous immunotherapy (SIT) in T-bet((-/-)) mice inhibited IL-6, IL-21R and lung TH17 cells in a setting of asthma. Finally, local delivery of an anti-IL-6R antibody in T-bet((-/-)) mice resulted in the resolution of this allergic trait. Noteworthy, BATF, crucial for the immunoglobulin-class-switch and TH2,TH17 development, was found down-regulated in the lungs of T-bet((-/-)) mice after SIT and after treatment with anti-IL-6R antibody, indicating a critical role of IL-6 in controlling BATF/IRF4 integrated functions in TH2, TH17 cells and B cells also in a T-bet independent fashion in allergic asthma

    Transient elastohydrodynamic lubrication analysis of a novel metal-on-metal hip prosthesis with a non-spherical femoral bearing surface

    No full text
    Effective lubrication performance of metal-on-metal hip implants only requires optimum conformity within the main loaded area, while it is advantageous to increase the clearance in the equatorial region. Such a varying clearance can be achieved by using non-spherical bearing surfaces for either acetabular or femoral components. An elastohydrodynamic lubrication model of a novel metal-on-metal hip prosthesis using a non-spherical femoral bearing surface against a spherical cup was solved under loading and motion conditions specified by ISO standard. A full numerical methodology of considering the geometric variation in the rotating non-spherical head in elastohydrodynamic lubrication solution was presented, which is applicable to all non-spherical head designs. The lubrication performance of a hip prosthesis using a specific non-spherical femoral head, Alpharabola, was analysed and compared with those of spherical bearing surfaces and a non-spherical Alpharabola cup investigated in previous studies. The sensitivity of the lubrication performance to the anteversion angle of the Alpharabola head was also investigated. Results showed that the non-spherical head introduced a large squeeze-film action and also led to a large variation in clearance within the loaded area. With the same equatorial clearance, the lubrication performance of the metal-on-metal hip prosthesis using an Alpharabola head was better than that of the conventional spherical bearings but worse than that of the metal-on-metal hip prosthesis using an Alpharabola cup. The reduction in the lubrication performance caused by the initial anteversion angle of the non-spherical head was small, compared with the improvement resulted from the non-spherical geometry

    Spatially resolved mass flux measurements with dual comb spectroscopy

    Get PDF
    Providing an accurate, representative sample of mass flux across large open areas for atmospheric studies or the extreme conditions of a hypersonic engine is challenging for traditional intrusive or point-based sensors. Here, we demonstrate that laser absorption spectroscopy with frequency combs can simultaneously measure all of the components of mass flux (velocity, temperature, pressure, and species concentration) with low uncertainty, spatial resolution corresponding to the span of the laser line of sight, and no supplemental sensor readings. The low uncertainty is provided by the broad spectral bandwidth, high resolution, and extremely well-known and controlled frequency axis of stabilized, mode-locked frequency combs. We demonstrate these capabilities in the isolator of a ground-test supersonic propulsion engine at Wright-Patterson Air Force Base. The mass flux measurements are consistent within 3.6% of the facility-level engine air supply values. A vertical scan of the laser beams in the isolator measures the spatially resolved mass flux, which is compared with computational fluid dynamics simulations. A rigorous uncertainty analysis demonstrates a DCS instrument uncertainty of ~0.4%, and total uncertainty (including non-instrument sources) of ~7% for mass flux measurements. These measurements demonstrate DCS as a low-uncertainty mass flux sensor for a variety of applications.Comment: Main Text: 15 pages, 7 figure; Supplement: 6 pages, 4 figures; Submitted to Optic

    Combined X-Ray and Fully Leaky Guided Mode Studies of the Smectic Layer and Optic Tensor Configuration in a Ferroelectric Liquid-Crystal Cell

    Get PDF
    B. Hodder, J. Roy Sambles, S. Jenkins, and R. M. Richardson, Physical Review Letters, Vol. 85, pp. 3181 - 3184 (2000). "Copyright © 2000 by the American Physical Society."X-ray scattering together with optical characterization using fully leaky guided modes have been used for the first time to study the same ferroelectric liquid-crystal cell. This enables direct calculation of an accurate cone and chevron description of the liquid-crystal director profile since the layer structure and optic tensor configuration are both well known
    corecore