14,583 research outputs found

    Capacitance multiplier and filter synthesizing network

    Get PDF
    A circuit using a differential amplifier multiplies the capacitance of a discrete interating capacitor by (r sub 1 + R sub 2)/R sub 2, where R sub 1 and R sub 2 are values of discrete resistor coupling an input signal e sub 1 of the amplifier inputs. The output e sub 0 of the amplifier is fed back and added to the signal coupled by the resistor R sub 2 to the amplifier through a resistor of value R sub 1. A discrete resistor R sub x may be connected in series for a lag filter, and a discrete resistor may be connected in series with the capacitor for a lead-lag filter. Voltage dividing resistors R sub a and R sub b may be included in the feedback circuit of the amplifier output e sub o to independently adjust the circuit gain e sub i/e sub o

    Phase-lock loop frequency control and the dropout problem

    Get PDF
    Technique automatically sets the frequency of narrow band phase-lock loops within automatic lock-in-range. It presets a phase-lock loop to a desired center frequency with a closed loop electronic frequency discriminator and holds the phase-lock loop to that center frequency until lock is achieved

    Fault detection and isolation for multisensor navigation systems

    Get PDF
    Increasing attention is being given to the problem of erroneous measurement data for multisensor navigation systems. A recursive estimator can be used in conjunction with a 'snapshot' batch estimator to provide fault detection and isolation (FDI) for these systems. A recursive estimator uses past system states to form a new state estimate and compares it to the calculated state based on a new set of measurements. A 'snapshot' batch estimator uses a set of measurements collected simultaneously and compares solutions based on subsets of measurements. The 'snapshot' approach requires redundant measurements in order to detect and isolate faults. FDI is also referred to as Receiver Autonomous Integrity Monitoring (RAIM)

    Defectors cannot be detected during"small talk" with strangers.

    Get PDF
    To account for the widespread human tendency to cooperate in one-shot social dilemmas, some theorists have proposed that cooperators can be reliably detected based on ethological displays that are difficult to fake. Experimental findings have supported the view that cooperators can be distinguished from defectors based on "thin slices" of behavior, but the relevant cues have remained elusive, and the role of the judge's perspective remains unclear. In this study, we followed triadic conversations among unacquainted same-sex college students with unannounced dyadic one-shot prisoner's dilemmas, and asked participants to guess the PD decisions made toward them and among the other two participants. Two other sets of participants guessed the PD decisions after viewing videotape of the conversations, either with foreknowledge (informed), or without foreknowledge (naïve), of the post-conversation PD. Only naïve video viewers approached better-than-chance prediction accuracy, and they were significantly accurate at predicting the PD decisions of only opposite-sexed conversation participants. Four ethological displays recently proposed to cue defection in one-shot social dilemmas (arms crossed, lean back, hand touch, and face touch) failed to predict either actual defection or guesses of defection by any category of observer. Our results cast doubt on the role of "greenbeard" signals in the evolution of human prosociality, although they suggest that eavesdropping may be more informative about others' cooperative propensities than direct interaction

    Communication system features dual mode range acquisition plus time delay measurement

    Get PDF
    Communication system combines range acquisition system and time measurement system for tracking high velocity aircraft and spacecraft. The range acquisition system uses a pseudonoise code to determine range and the time measurement system reduces uncontrolled phase variations in the demodulated signal

    Disposable Hand-Held Device for Collection of Exhaled Breath Condensate

    Get PDF
    A breath condensate collection apparatus comprising a central chamber, a breath input assembly, a plunger assembly and a breath condensate collection port. The central chamber has inner and outer side walls with a coolant material sealed in between. The breath input assembly is disposed on the side of the central chamber in fluid communication with the chamber interior. The plunger assembly has a piston, slidably disposed in the chamber, and a handle extending from a first end of the chamber. The collection port is disposed at the second end of the central chamber in fluid communication with the interior of the chamber. Obstructive structures may be arranged in the chamber interior for increasing the surface area on which condensate may form. The apparatus may also include an outlet assembly that may be removed and replaced with a sampling well into which the condensate may be washed with a buffer solution

    Method and System for Diagnosing Post-Surgical Pulmonary Vascular Occlusions

    Get PDF
    A method of determining the presence of pulmonary embolism is a postoperative patient using the carbox ratio of the patient prior to the surgical procedure and the carbox ratio of the patient after to the surgical procedure. The characteristics of the breath of the patient are obtained prior to a surgical procedure for a baseline and then afterwards if the patient has difficult breathing. The mean carbox ratios from the baseline and post-surgical data collections are then compared to noninvasively predict the likelihood that the patient has developed pulmonary embolism. A decrease in the carbox ratio of more than twenty-five percent (25%) represents an abnormal test and is consistent with possible pulmonary embolism. No change or an increase in the carbox ratio suggests the absence of pulmonary embolism

    NON-INVASIVE DEVICE AND METHOD FOR MEASURING THE CARDIAC OUTPUT OF A PATIENT

    Get PDF
    A method and system for detecting the presence of restriction to expired airflow in humans or animals by analyzing the expired capnogram and oxygram, as well as the geometric analysis of the real-time plot of the waveform that depicts the instantaneous ratio of CO2 to O2 (the carboxygram ratio). Airway obstructions causes an increase in the Q-angle between the slope of phase 11 and slope of phase III in the expired carboxygram. The diagnostic accuracy of the detection of airways obstruction is further enhanced by measuring the ratio of time spent in exhalation (Te) versus inhalation (Ti). The system uses the combination of an increased carboxygram Q-angle, and a prolonged Te/Ti to detect presence of airways obstruction

    NON-INVASIVE DEVICE AND METHOD FOR THE DIAGNOSIS OF PULMONARY VASCULAR OCCLUSIONS

    Get PDF
    The invention involves a device and method for ascertaining the functioning of the respiratory system and determining whether a pulmonary embolism is present. The device comprises an apparatus containing sensors which measure the amount of a particular gas expired from a patient's lungs, including a non-ambient gas which is previously provided to the patent. From this data, a processor computes the concentration of expired gas as a function of expired volume and displays the results on a screen. By comparing the results to predetermined values from afflicted and healthy patient populations, an accurate determination can be made regarding the presence of a pulmonary embolism

    SYSTEM AND METHOD FOR DETERMINING AIRWAY OBSTRUCTION

    Get PDF
    A method and system for detecting the presence of restriction to expired airflow in humans or animals by analyzing the expired capnogram and oxygram, as well as the geometric analysis of the real-time plot of the waveform that depicts the instantaneous ratio of CO2 to O2 (the carboxygram ratio). Airway obstructions causes an increase in the Q-angle between the slope of phase 11 and slope of phase III in the expired carboxygram. The diagnostic accuracy of the detection of airways obstruction is further enhanced by measuring the ratio of time spent in exhalation (Te) versus inhalation (Ti). The system uses the combination of an increased carboxygram Q-angle, and a prolonged Te/Ti to detect presence of airways obstruction
    • …
    corecore