5,031 research outputs found

    Pareto Analysis on the Total Quality Management (TQM) Status of the Nigerian Design Firms

    Get PDF
    This research sought to establish the status of the Nigerian Design Firms using European Construction Institute (ECI) Total Quality Management Matrix; and identified major factors responsible for the poor performance of the Nigerian design firms. Data for the study was obtained from a sample of 237 design firms across the country using ECI measurement matrix. Results were computed as outlined by ECI which was used to establish the status of the firms. Pareto Analysis was conducted to identify the vital factors. Result of ECI measurement matrix revealed that the Nigerian Building Design Firms scored an overall average of 27.4 points which placed them in the 4th ECI category – 'the Start of Improvement.' This indicated poor performance. Three quality factors identified using the Pareto Analysis were 'Training, awareness, education and skill' (3.3 ECI score), 'Objective measurement and feedback' (3.4) and 'Natural use of TQ tools and techniques' (3.4). Therefore, firms' programme relating to TQM should be improved beyond partial implementation. In particular, staff training should be provided, firms should create environment for natural use of TQM tools and techniques, while objective measurement and feedback be established.Keywords: Design Firms, Measurement Matrix, Pareto Analysis, Quality Factors, Total Quality Management

    Location of a local lesion gene in tobacco mosaic virus RNA.

    Full text link

    Extracellular Nm23H1 stimulates neurite outgrowth from dorsal root ganglia neurons in vitro independently of nerve growth factor supplementation or its nucleoside diphosphate kinase activity

    Get PDF
    The nucleoside diphosphate (NDP) kinase, Nm23H1, is a highly expressed during neuronal development, whilst induced over-expression in neuronal cells results in increased neurite outgrowth. Extracellular Nm23H1 affects the survival, proliferation and differentiation of non-neuronal cells. Therefore, this study has examined whether extracellular Nm23H1 regulates nerve growth. We have immobilised recombinant Nm23H1 proteins to defined locations of culture plates, which were then seeded with explants of embryonic chick dorsal root ganglia (DRG) or dissociated adult rat DRG neurons. The substratum-bound extracellular Nm23H1 was stimulatory for neurite outgrowth from chick DRG explants in a concentration-dependent manner. On high concentrations of Nm23H1, chick DRG neurite outgrowth was extensive and effectively limited to the location of the Nm23H1, i.e. neuronal growth cones turned away from adjacent collagen-coated substrata. Nm23H1-coated substrata also significantly enhanced rat DRG neuronal cell adhesion and neurite outgrowth in comparison to collagen-coated substrata. These effects were independent of NGF supplementation. Recombinant Nm23H1 (H118F), which does not possess NDP kinase activity, exhibited the same activity as the wild-type protein. Hence, a novel neuro-stimulatory activity for extracellular Nm23H1 has been identified in vitro, which may function in developing neuronal systems

    The reliability and validity of three non-radiological measures of thoracic kyphosis and their relations to the standing radiological Cobb angle

    Get PDF
    UnlabelledHyperkyphosis is implicated in a mounting list of negative outcomes, including higher mortality. Hyperkyphosis research is hindered due to difficulties inherent in its measurement. By showing that three clinical measures of kyphosis are suitable for use in large scale, longitudinal, hyperkyphosis studies, we will facilitate much needed research in this field.IntroductionThe objective of this study is to describe the reliability of three non-radiological kyphosis measures (Debrunner kyphosis angle, flexicurve kyphosis index, and flexicurve kyphosis angle) and their validity compared to the Cobb angle and to approximate a Cobb angle from non-radiological kyphosis measures.MethodsWe analyzed data from 113 participants aged ≥ 60 years with kyphosis angle ≥ 40°. Cobb angle was measured on a standing lateral thoracolumbar radiograph using bounds at T4 and T12. Non-radiological measures of kyphosis were made three times by a single rater and a 4th time by a blinded second rater.ResultsIntra- and inter-rater reliabilities for non-radiological assessments were high (intra-class correlations of 0.96 to 0.98) and did not differ from each other. Pearson correlations, estimating validity, ranged from 0.62 to 0.69 and did not differ. The Debrunner angle was close to the Cobb angle, with scaling factor of 1.067 and an offset of 5°. The Flexicurve kyphosis angle had to be scaled by 1.53 to obtain the equivalent Cobb angle. The scaling factor for the Flexicurve kyphosis index to Cobb angle was 315, with an offset of 5°. Compared to the measured Cobb angle, Cobb angles predicted using the non-radiological measures had similar magnitude errors (standard deviations of the differences ranging between 10.24 and 11.26).ConclusionsEach non-radiological measurement had similar reliability and validity. Low cost, ease of use, and robustness to variations in spine contour argue for the Flexicurve in longitudinal kyphosis assessments. The approximate conversion factors provided will permit translation of non-radiological measures to Cobb angles
    corecore