51 research outputs found
Simulating Ion Microtomography Data for Improving Reconstruction Quality
Ion Microtomography (IMT) provides quantitative, fine resolution density imaging of samples for materials characterization. Reconstructed tomographic images are obtained by application of a filtered backprojection algorithm to the collected data. The attainable resolution and data acquisition rate are affected by several parameters. These include the number of ions measured per spot, using either the mean or median residual energy, utilizing Bragg additivity, changing the number of rays or the number of projections and oversampling the data. A tomography simulation computer program is described and used to study the contributions from these effects on the numerical reconstruction of an array of silicon pillars
Recommended from our members
Cadmium zinc telluride charged particle nuclear detectors
This report describes the improvements in understanding of transport phenomena in cadmium zinc telluride radiation sensors achieved through studies of alpha particle response and spatially resolved photoconductivity mapping. Alpha particle response waveforms and photocurrent profiles both indicate non-uniformities in the electric field which may have detrimental effects on detector performance. Identifying and eliminating the sources of these nonuniformities will ultimately lead to improved detector performance
Recommended from our members
Coaxial Mono-Energetic Gamma Generator for Active Interrogation
Compact mono-energetic photon sources are sought for active interrogation systems to detect shielded special nuclear materials in, for example, cargo containers, trucks and other vehicles. A prototype gamma interrogation source has been designed and built that utilizes the 11B(p,gamma)12C reaction to produce 12 MeV gamma-rays which are near the peak of the photofission cross section. In particular, the 11B(p,gamma)12C resonance at 163 kV allows the production of gammas at low proton acceleration voltages, thus keeping the design of a gamma generator comparatively small and simple. A coaxial design has been adopted with a toroidal-shaped plasma chamber surrounding a cylindrical gamma production target. The plasma discharge is driven by a 2 MHz rf-power supply (capable up to 50 kW) using a circular rf-antenna. Permanent magnets embedded in the walls of the plasma chamber generate a multi-cusp field that confines the plasma and allows higher plasma densities and lower gas pressures. About 100 proton beamlets are extracted through a slotted plasma electrode towards the target at the center of the device that is at a negative 180 kV. The target consists of LaB6 tiles that are brazed to a water-cooled cylindrical structure. The generator is designed to operate at 500 Hz with 20 mu s long pulses, and a 1percent duty factor by pulsing the ion source rf-power. A first-generation coaxial gamma source has been built for low duty factor experiments and testing
Advances in chemical and biological methods to identify microorganisms—from past to present
Fast detection and identification of microorganisms is a challenging and significant feature from industry to medicine. Standard approaches are known to be very time-consuming and labor-intensive (e.g., culture media and biochemical tests). Conversely, screening techniques demand a quick and low-cost grouping of bacterial/fungal isolates and current analysis call for broad reports of microorganisms, involving the application of molecular techniques (e.g., 16S ribosomal RNA gene sequencing based on polymerase chain reaction). The goal of this review is to present the past and the present methods of detection and identification of microorganisms, and to discuss their advantages and their limitations.C.F.R. would like to thank the Portuguese Foundation for Science and Technology (FCT–Portugal) for the C.F.R. for the project UID/EQU/00511/2019—Laboratory for Process Engineering, Environment, Biotechnology, and Energy—LEPABE funded by national funds through FCT/MCTES (PIDDAC) and N.M. for the Strategic project ref. UID/BIM/04293/2013 and “NORTE2020 - Programa Operacional Regional do Norte” (NORTE-01-0145-FEDER-000012)
Planning target volume margins for prostate radiotherapy using daily electronic portal imaging and implanted fiducial markers
<p>Abstract</p> <p>Background</p> <p>Fiducial markers and daily electronic portal imaging (EPI) can reduce the risk of geographic miss in prostate cancer radiotherapy. The purpose of this study was to estimate CTV to PTV margin requirements, without and with the use of this image guidance strategy.</p> <p>Methods</p> <p>46 patients underwent placement of 3 radio-opaque fiducial markers prior to prostate RT. Daily pre-treatment EPIs were taken, and isocenter placement errors were corrected if they were ≥ 3 mm along the left-right or superior-inferior axes, and/or ≥ 2 mm along the anterior-posterior axis. During-treatment EPIs were then obtained to estimate intra-fraction motion.</p> <p>Results</p> <p>Without image guidance, margins of 0.57 cm, 0.79 cm and 0.77 cm, along the left-right, superior-inferior and anterior-posterior axes respectively, are required to give 95% probability of complete CTV coverage each day. With the above image guidance strategy, these margins can be reduced to 0.36 cm, 0.37 cm and 0.37 cm respectively. Correction of all isocenter placement errors, regardless of size, would permit minimal additional reduction in margins.</p> <p>Conclusions</p> <p>Image guidance, using implanted fiducial markers and daily EPI, permits the use of narrower PTV margins without compromising coverage of the target, in the radiotherapy of prostate cancer.</p
Tagetes spp. Essential oils and other extracts : chemical characterization and biological activity
Tagetes (marigold) is native to America, and its cultivation currently extends to other countries in Africa, Asia, and Europe. Many species of this genus, such as T. minuta, T. erecta, T. patula, and T. tenuifolia, are cultivated as ornamental plants and studied for their medicinal properties on the basis of their use in folk medicine. Different parts of the Tagetes species are used as remedies to treat various health problems, including dental, stomach, intestinal, emotional, and nervous disorders, as well as muscular pain, across the world. Furthermore, these plants are studied in the field of agriculture for their fungicidal, bactericidal, and insecticidal activities. The phytochemical composition of the extracts of different Tagetes species parts are reported in this work. These compounds exhibit antioxidant, antiinflammatory, and enzyme inhibitory properties. Cultivation and the factors affecting the chemical composition of Tagetes species are also covered. In the current work, available literature on Tagetes species in traditional medicine, their application as a food preservative, and their antimicrobial activities are reviewed
Pudendal nerve decompression in perineology : a case series
BACKGROUND: Perineodynia (vulvodynia, perineal pain, proctalgia), anal and urinary incontinence are the main symptoms of the pudendal canal syndrome (PCS) or entrapment of the pudendal nerve. The first aim of this study was to evaluate the effect of bilateral pudendal nerve decompression (PND) on the symptoms of the PCS, on three clinical signs (abnormal sensibility, painful Alcock's canal, painful "skin rolling test") and on two neurophysiological tests: electromyography (EMG) and pudendal nerve terminal motor latencies (PNTML). The second aim was to study the clinical value of the aforementioned clinical signs in the diagnosis of PCS. METHODS: In this retrospective analysis, the studied sample comprised 74 female patients who underwent a bilateral PND between 1995 and 2002. To accomplish the first aim, the patients sample was compared before and at least one year after surgery by means of descriptive statistics and hypothesis testing. The second aim was achieved by means of a statistical comparison between the patient's group before the operation and a control group of 82 women without any of the following signs: prolapse, anal incontinence, perineodynia, dyschesia and history of pelvi-perineal surgery. RESULTS: When bilateral PND was the only procedure done to treat the symptoms, the cure rates of perineodynia, anal incontinence and urinary incontinence were 8/14, 4/5 and 3/5, respectively. The frequency of the three clinical signs was significantly reduced. There was a significant reduction of anal and perineal PNTML and a significant increase of anal richness on EMG. The Odd Ratio of the three clinical signs in the diagnosis of PCS was 16,97 (95% CI = 4,68 – 61,51). CONCLUSION: This study suggests that bilateral PND can treat perineodynia, anal and urinary incontinence. The three clinical signs of PCS seem to be efficient to suspect this diagnosis. There is a need for further studies to confirm these preliminary results
cExternal beam radiation results in minimal changes in post void residual urine volumes during the treatment of clinically localized prostate cancer
<p>Abstract</p> <p>Background</p> <p>To evaluate the impact of external beam radiation therapy (XRT) on weekly ultrasound determined post-void residual (PVR) urine volumes in patients with prostate cancer.</p> <p>Methods</p> <p>125 patients received XRT for clinically localized prostate cancer. XRT was delivered to the prostate only (n = 66) or if the risk of lymph node involvement was greater than 10% to the whole pelvis followed by a prostate boost (n = 59). All patients were irradiated in the prone position in a custom hip-fix mobilization device with an empty bladder and rectum. PVR was obtained at baseline and weekly. Multiple clinical and treatment parameters were evaluated as predictors for weekly PVR changes.</p> <p>Results</p> <p>The mean patient age was 73.9 years with a mean pre-treatment prostate volume of 53.3 cc, a mean IPSS of 11.3 and a mean baseline PVR of 57.6 cc. During treatment, PVR decreased from baseline in both cohorts with the absolute difference within the limits of accuracy of the bladder scanner. Alpha-blockers did not predict for a lower PVR during treatment. There was no significant difference in mean PVR urine volumes or differences from baseline in either the prostate only or pelvic radiation groups (p = 0.664 and p = 0.458, respectively). Patients with a larger baseline PVR (>40 cc) had a greater reduction in PVR, although the greatest reduction was seen between weeks one and three. Patients with a small PVR (<40 cc) had no demonstrable change throughout treatment.</p> <p>Conclusion</p> <p>Prostate XRT results in clinically insignificant changes in weekly PVR volumes, suggesting that radiation induced bladder irritation does not substantially influence bladder residual urine volumes.</p
- …