7,657 research outputs found

    Black hole hunting in the Andromeda Galaxy

    Full text link
    We present a new technique for identifying stellar mass black holes in low mass X-ray binaries (LMXBs), and apply it to XMM-Newton observations of M31. We examine X-ray time series variability seeking power density spectra (PDS) typical of LMXBs accreting at a low accretion rate (which we refer to as Type A PDS); these are very similar for black hole and neutron star LMXBs. Galactic neutron star LMXBs exhibit Type A PDS at low luminosities (~10^36--10^37 erg/s) while black hole LMXBs can exhibit them at luminosities >10^38 erg/s. We propose that Type A PDS are confined to luminosities below a critical fraction of the Eddington limit, lcl_c that is constant for all LMXBs; we have examined asample of black hole and neutron star LMXBs and find they are all consistent with lcl_c = 0.10+/-0.04 in the 0.3--10 keV band. We present luminosity and PDS data from 167 observations of X-ray binaries in M31 that provide strong support for our hypothesis. Since the theoretical maximum mass for a neutron star is \~3.1 M_Sun, we therefore assert that any LMXB that exhibits a Type A PDS at a 0.3--10 keV luminosity greater than 4 x 10^37 erg/s is likely to contain a black hole primary. We have found eleven new black hole candidates in M31 using this method. We focus on XMM-Newton observations of RX J0042.4+4112, an X-ray source in M31 and find the mass of the primary to be 7+/-2 M_Sun, if our assumptions are correct. Furthermore, RX J0042.4+4112 is consistently bright in \~40 observations made over 23 years, and is likely to be a persistently bright LMXB; by contrast all known Galactic black hole LMXBs are transient. Hence our method may be used to find black holes in known, persistently bright Galactic LMXBs and also in LMXBs in other galaxies.Comment: 6 Pages, 6 figures. To appear in the conference proceedings of "Interacting Binaries: Accretion, Evolution and Outcomes" (Cefalu, July 4-10 2004

    Systems, interactions and macrotheory

    Get PDF
    A significant proportion of early HCI research was guided by one very clear vision: that the existing theory base in psychology and cognitive science could be developed to yield engineering tools for use in the interdisciplinary context of HCI design. While interface technologies and heuristic methods for behavioral evaluation have rapidly advanced in both capability and breadth of application, progress toward deeper theory has been modest, and some now believe it to be unnecessary. A case is presented for developing new forms of theory, based around generic “systems of interactors.” An overlapping, layered structure of macro- and microtheories could then serve an explanatory role, and could also bind together contributions from the different disciplines. Novel routes to formalizing and applying such theories provide a host of interesting and tractable problems for future basic research in HCI

    A Model to Measure the Service Quality of Pharmaceutical Wholesalers

    Get PDF
    The study constituters a model to measure the service quality of pharmaceutical wholesalers in South Africa. Several pharmaceutical wholesalers distribute medical supplies throughout South Africa in a very regulated and competitive market where high service quality levels are anticipated. In this price-undifferentiated market, service quality can have a significant impact on the competitiveness of a pharmaceutical wholesaler. As a result, the primary objective was to develop a model to measure the service quality levels of large pharmaceutical wholesalers. The literature study compiled an industry profile of the South African pharmaceutical market, analysed service quality and then proposed an adapted SERVQUAL model to measure the service quality. A review of the literature also highlighted the general structure of the pharmaceutical industry and the regulatory framework in the supply of pharmaceutical products. The literature study also focuses specifically on the role and function of the pharmaceutical wholesaler in the supply chain. Data was collected from clients of a pharmaceutical wholesaler using to record the service expectations and perceptions on a seven-point Likert scale. Some 385 of the 4468 clients completed and returned the industry-adapted SERVQUAL survey questionnaires on the electronic platform Google Forms (signifying an 8.6% response rate). The results showed that the data were reliable with a Cronbach alpha coefficient higher than 0.70. The results also show that in five, the service dimensions gap where perceptions and expectations are measured had negative gaps. This means that the clients expected better service quality than what they received. The service dimension Assurance showed the largest gap, while Tangibility had the smallest gap. However, none of these gaps was practically significant. Further analysis using exploratory factor analysis identified three underlying service quality variables, namely Positive employee actions, Business process management and Marketing channels. These factors explained a favourable cumulative variance of 67.7%. The study finally proposes a model to measure service quality in the pharmaceutical wholesale industry

    Professional nurses’ perception of their clinical teaching role at a rural hospital in Lesotho

    Get PDF
    Background. Nursing education institutions in Lesotho face an increasing number of enrolments owing to a high demand for professional nurses to work in the community. Enrolments have doubled during the last 3 years, without an increase in teaching resources or staff. Professional nurses in the wards are expected to mentor students and teach the clinical elements of nursing while continuing with their day-to-day clinical duties. Furthermore, professional nurses in Lesotho have not been trained for this clinical teaching role.Objective. To explore the perceptions of professional nurses with regard to their clinical teaching role in the development of competent nurses.Methods. A qualitative study was undertaken at a rural hospital in Lesotho. Data were gathered by conducting semi-structured interviews with professionalnurses. Interview transcripts were coded and emerging themes identified. Data saturation was reached after eight interview transcripts were analysed.Results. Four themes representing the perceptions of the professional nurses emerged in the analysis: (i) the clinical teaching role; (ii) the complexities of clinical teaching; (iii) learners have their issues; and (iv) making it work.Conclusion. Professional nurses understand and appreciate their educationalrole in the development of competent nurses. This clinical teaching role is performed in difficult circumstances, including administrative challenges, limited resources and staff shortages, while maintaining clinical responsibilities. Despite these challenges, the nurses have remained resilient and solution focused. Nursing education institutions should re-orientate professional nurses with regard to current trends and principles of nursing education to enhance their clinical teaching role

    On the artificial nature of aperiodic variability in XMM-Newton observations of M 31 X-ray sources and the ultraluminous X-ray source NGC 4559 ULX-7

    Get PDF
    Context: Power density spectra (PDS) that are characteristic of low mass X-ray binaries (LMXBs) have been previously reported for M 31 X-ray sources, observed by XMM-Newton. However, we have recently discovered that these PDS result from the improper addition/subtraction of non-simultaneous lightcurves. Aims: To understand the properties and origins of the artefact. Methods: We re-analysed our XMM-Newton observations of M 31 with non-simultaneous and simultaneous lightcurves, then combined simulated lightcurves at various intensities with various offsets and found that the artefact is more dependent on the offset than the intensity. Results: The lightcurves produced by the XMM-Newton Science Analysis Software (SAS) are non-synchronised by default. This affects not only the combination of lightcurves from the three EPIC detectors (MOS1, MOS2 and pn), but also background subtraction in the same CCD. It is therefore imperative that all SAS-generated lightcurves are synchronised by time filtering, even if the whole observation is to be used. We also find that the reported timing behaviour for NGC 4559 ULX-7 was also contaminated by the artefact; there is no significant variability in the correctly-combined lightcurves of NGC 4559 ULX-7. Hence, the classification of this source as an intermediate-mass black hole is no longer justified. Conclusions: While previous timing results from M 31 have been proven wrong, and also the broken power law PDS in NGC 4559 ULX-7, XMM-Newton was able to detect aperiodic variability in just 3 ks of observations of NGC 5408 ULX1. Hence XMM-Newton remains a viable tool for analysing variability in extra-galactic X-ray sources

    Discovery of disc precession in the M31 dipping X-ray binary Bo 158

    Full text link
    We present results from three XMM-Newton observations of the M31 low mass X-ray binary XMMU J004314.4+410726.3 (Bo 158), spaced over 3 days in 2004, July. Bo 158 was the first dipping LMXB to be discovered in M31. Periodic intensity dips were previously seen to occur on a 2.78-hr period, due to absorption in material that is raised out of the plane of the accretion disc. The report of these observations stated that the dip depth was anti-correlated with source intensity. However, our new observations do not favour a strict intensity dependance, but rather suggest that the dip variation is due to precession of the accretion disc. This is to be expected in LMXBs with a mass ratio <~ 0.3 (period <~ 4 hr), as the disc reaches the 3:1 resonance with the binary companion, causing elongation and precession of the disc. A smoothed particle hydrodynamics simulation of the disc in this system shows retrograde rotation of a disc warp on a period of ~11 P_orb, and prograde disc precession on a period of ~29 P_orb. This is consistent with the observed variation in the depth of the dips. We find that the dipping behaviour is most likely to be modified by the disc precession, hence we predict that the dipping behaviour repeats on a 81+/-3 hr cycle.Comment: 9 pages, 6 figures, accepted for publication by MNRAS, changed conten

    XMM-Newton reveals ~100 new LMXBs in M31 from variability studies

    Full text link
    We have conducted a survey of X-ray sources in XMM-Newton observations of M31, examining their power density spectra (PDS) and spectral energy distributions (SEDs). Our automated source detection yielded 535 good X-ray sources; to date, we have studied 225 of them. In particular, we examined the PDS because low mass X-ray binaries (LMXBs) exhibit two distinctive types of PDS. At low accretion rates, the PDS is characterised by a broken power law, with the spectral index changing from ~0 to ~1 at some frequency in the range \~0.01--1 Hz; we refer to such PDS as Type A. At higher accretion rates, the PDS is described by a simple power law; we call these PDS Type B. Of the 225 sources studied to date, 75 exhibit Type A variability, and are almost certainly LMXBs, while 6 show Type B but not Type A, and are likely LMXBs. Of these 81 candidate LMXBs, 71 are newly identified in this survey; furthermore, they are mostly found near the centre of M31. Furthermore, most of the X-ray population in the disc are associated with the spiral arms, making them likely high mass X-ray binaries (HMXBs). In general these HMXBs do not exhibit Type A variability, while many central X-ray sources (LMXBs) in the same luminosity range do. Hence the PDS may distinguish between LMXBs and HMXBs in this luminosity range.Comment: 4 pages, 2 figures. To appear in proceedings of IAUS230: "Populations of High Energy Sources in Galaxies", 14-19 August 2005, Dublin, Eds E.J.A. Meurs and G. Fabbian

    Energy-dependent evolution in IC10 X-1: hard evidence for an extended corona and implications

    Get PDF
    We have analyzed a ~130 ks XMM-Newton observation of the dynamically confirmed black hole + Wolf-Rayet (BH+WR) X-ray binary (XB) IC10 X-1, covering ~1 orbital cycle. This system experiences periodic intensity dips every ~35 hr. We find that energy-independent evolution is rejected at a >5σ level. The spectral and timing evolution of IC10 X-1 are best explained by a compact disk blackbody and an extended Comptonized component, where the thermal component is completely absorbed and the Comptonized component is partially covered during the dip. We consider three possibilities for the absorber: cold material in the outer accretion disk, as is well documented for Galactic neutron star (NS) XBs at high inclination; a stream of stellar wind that is enhanced by traveling through the L1 point; and a spherical wind. We estimated the corona radius (r ADC) for IC10 X-1 from the dip ingress to be ~106 km, assuming absorption from the outer disk, and found it to be consistent with the relation between r ADC and 1-30 keV luminosity observed in Galactic NS XBs that spans two orders of magnitude. For the other two scenarios, the corona would be larger. Prior BH mass (M BH) estimates range over 23-38 M ☉, depending on the inclination and WR mass. For disk absorption, the inclination, i, is likely to be ~60-80°, with M BH ~ 24-41 M ☉. Alternatively, the L1-enhanced wind requires i ~ 80°, suggesting ~24-33 M ☉. For a spherical absorber, i ~ 40°, and M BH ~ 50-65 M ☉

    The Effect of an Offset Polar Cap Dipolar Magnetic Field on the Modeling of the Vela Pulsar's Gamma-Ray Light Curves

    Get PDF
    We performed geometric pulsar light curve modeling using static, retarded vacuum, and offset polar cap (PC) dipole B-fields (the latter is characterized by a parameter epsilon), in conjunction with standard two-pole caustic (TPC) and outer gap (OG) emission geometries. The offset-PC dipole B-field mimics deviations from the static dipole (which corresponds to epsilon equals 0). In addition to constant-emissivity geometric models, we also considered a slot gap (SG) E-field associated with the offset-PC dipole B-field and found that its inclusion leads to qualitatively different light curves. Solving the particle transport equation shows that the particle energy only becomes large enough to yield significant curvature radiation at large altitudes above the stellar surface, given this relatively low E-field. Therefore, particles do not always attain the radiation-reaction limit. Our overall optimal light curve fit is for the retarded vacuum dipole field and OG model, at an inclination angle alpha equals 78 plus or minus 1 degree and observer angle zeta equals 69 plus 2 degrees or minus 1 degree. For this B-field, the TPC model is statistically disfavored compared to the OG model. For the static dipole field, neither model is significantly preferred. We found that smaller values of epsilon are favored for the offset-PC dipole field when assuming constant emissivity, and larger epsilon values favored for variable emissivity, but not significantly so. When multiplying the SG E-field by a factor of 100, we found improved light curve fits, with alpha and zeta being closer to best fits from independent studies, as well as curvature radiation reaction at lower altitudes
    corecore