153 research outputs found

    Feasibility of therapeutic pneumoperitoneum in a large animal model using a microvaporisator

    Get PDF
    Background: Multimodal therapy is used increasingly in advanced gastrointestinal tumors. Potential benefits of using an intraoperative adjuvant therapy during laparoscopy for cancer have been documented in animal studies. The aim of this study was to develop a device that could deliver such an intraoperative drug therapy. Methods: We developed a micropump suitable for minimally invasive surgery procedures that allowed microdroplets of therapeutic substance to be distributed into the pneumoperitoneum (CO2), creating a "therapeutic pneumoperitoneum.” A closed-loop control system regulates drug delivery according to the gas flow. In vitro, the micropump is able to aerosolize various aqueous and ethanol solutions, including cytostatic and bacteriostatic drugs and adhesionmodulating agents. The size of the microdroplets has been optimized to prevent visual artifacts. Results: The micropump was tested in an animal model (pig). The system was inserted into a 5-mm trocar. After insufflation of a 12-mm CO2 pneumoperitoneum, laparoscopic sigmoid colon resections could be performed with no special difficulties. No fog developed, and no systemrelated complication was observed. At autopsy, the active principle was distributed to all exposed peritoneal surfaces. Conclusions: As opposed to conventional peritoneal washing, therapeutic pneumoperitoneum reaches the entire peritoneal surface, allowing an optimal drug distribution. Drug diffusion into the tissues is enhanced by the intraperitoneal pressure. Precise determination of the instantaneous and total drug quantity is possible. Therefore, this drug delivery system has several advantages over conventional irrigation. Its potential domains of application are locoregional cancer therapy, prevention of port-site recurrences, immunomodulation, analgesia, peritonitis, and prevention of postoperative adhesion

    Easily Vaporizable Ionic Liquids - No Contradiction!

    Get PDF
    Copyright © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim. It was a big surprise to see crystals of an ionic liquid (IL) forming by sublimation at room temperature. ILs are generally accepted to have negligible vapour pressures at elevated temperatures, making their sublimation or distillation very difficult. ILs that sublime easily contain silylimidazolium-based cations. In order to establish the details of the unusual behaviour of this subclass of ILs, a combined spectroscopic, X-ray crystallographic, physicochemical and theoretical characterization was performed. The results are compared with those of other easily vaporizable compounds, like ammonium chloride and naphthalene. The single-crystal X-ray structure analysis of one of these compounds, N-methyl-N′-dimethyl(phenyl)silylimidazolium chloride (monoclinic, C2/c), clearly shows the existence of isolated ions, demonstrating that the compound is an ionic liquid. Ionic liquids (ILs) are commonly known as compounds with negligible vapour pressure, which makes them difficult to boil/distil or sublime. Surprisingly, ILs with imidazolium-based cations with the specialty of N-bonded silylorganic groups sublime very easily. The process of sublimation has been investigated thoroughly with physicochemical methods and theoretical calculations

    Five-Year Follow-Up of a Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) in VHWG Grade 3 Incisional Hernia Repair

    Get PDF
    OBJECTIVE: To assess the 5-year recurrence rate of incisional hernia repair in Ventral Hernia Working Group (VHWG) 3 hernia with a slowly resorbable mesh.SUMMARY BACKGROUND DATA: Incisional hernia recurs frequently after initial repair. In potentially contaminated hernia, recurrences rise to 40%. Recently, the biosynthetic Phasix mesh has been developed that is resorbed in 12-18 months. Resorbable meshes might be a solution for incisional hernia repair to decrease short- and long-term (mesh) complications. However, long-term outcomes after resorption are scarce.METHODS: Patients with VHWG grade 3 incisional midline hernia, who participated in the Phasix trial (Clinilcaltrials.gov: NCT02720042) were included by means of physical examination and computed tomography (CT). Primary outcome was hernia recurrence; secondary outcomes comprised of long-term mesh complications, reoperations, and abdominal wall pain [visual analogue score (VAS): 0-10].RESULTS: In total, 61/84 (72.6%) patients were seen. Median follow-up time was 60.0 [interquartile range (IQR): 55-64] months. CT scan was made in 39 patients (68.4%). A recurrence rate of 15.9% (95% confidence interval: 6.9-24.8) was calculated after 5 years. Four new recurrences (6.6%) were found between 2 and 5 years. Two were asymptomatic. In total, 13/84 recurrences were found. No long-term mesh complications and/or interventions occurred. VAS scores were 0 (IQR: 0-2).CONCLUSIONS: Hernia repair with Phasix mesh in high-risk patients (VHWG 3, body mass index &gt;28) demonstrated a recurrence rate of 15.9%, low pain scores, no mesh-related complications or reoperations for chronic pain between the 2- and 5-year follow-up. Four new recurrences occurred, 2 were asymptomatic. The poly-4-hydroxybutyrate mesh is a safe mesh for hernia repair in VHWG 3 patients, which avoids long-term mesh complications like pain and mesh infection.</p

    EuraHS: the development of an international online platform for registration and outcome measurement of ventral abdominal wall hernia repair

    Get PDF
    Background Although the repair of ventral abdominal wall hernias is one of the most commonly performed operations, many aspects of their treatment are still under debate or poorly studied. In addition, there is a lack of good definitions and classifications that make the evaluation of studies and meta-analyses in this field of surgery difficult. Materials and methods Under the auspices of the board of the European Hernia Society and following the previously published classifications on inguinal and on ventral hernias, a working group was formed to create an online platform for registration and outcome measurement of operations for ventral abdominal wall hernias. Development of such a registry involved reaching agreement about clear definitions and classifications on patient variables, surgical procedures and mesh materials used, as well as outcome parameters. The EuraHS working group (European registry for abdominal wall hernias) comprised of a multinational European expert panel with specific interest in abdominal wall hernias. Over five working group meetings, consensus was reached on definitions for the data to be recorded in the registry. Results A set of well-described definitions was made. The previously reported EHS classifications of hernias will be used. Risk factors for recurrences and co-morbidities of patients were listed. A new severity of comorbidity score was defined. Post-operative complications were classified according to existing classifications as described for other fields of surgery. A new 3-dimensional numerical quality-of-life score, EuraHS-QoL score, was defined. An online platform is created based on the definitions and classifications, which can be used by individual surgeons, surgical teams or for multicentre studies. A EuraHS website is constructed with easy access to all the definitions, classifications and results from the database. Conclusion An online platform for registration and outcome measurement of abdominal wall hernia repairs with clear definitions and classifications is offered to the surgical community. It is hoped that this registry could lead to better evidence-based guidelines for treatment of abdominal wall hernias based on hernia variables, patient variables, available hernia repair materials and techniques

    A post-market, prospective, multi-center, single-arm clinical investigation of Phasix™ mesh for VHWG grade 3 midline incisional hernia repair

    Get PDF
    BACKGROUND: Incisional heia is a frequent complication of midline laparotomy. The use of mesh in hernia repair has been reported to lead to fewer recurrences compared to primary repair. However, in Ventral Hernia Working Group (VHWG) Grade 3 hernia patients, whose hernia is potentially contaminated, synthetic mesh is prone to infection. There is a strong preference for resorbable biological mesh in contaminated fields, since it is more able to resist infection, and because it is fully resorbed, the chance of a foreign body reaction is reduced. However, when not crosslinked, biological resorbable mesh products tend to degrade too quickly to facilitate native cellular ingrowth. Phasix™ Mesh is a biosynthetic mesh with both the biocompatibility and resorbability of a biological mesh and the mechanical strength of a synthetic mesh. This multi-center single-arm study aims to collect data on safety and performance of Phasix™ Mesh in Grade 3 hernia patients. METHODS: A total of 85 VHWG Grade 3 hernia patients will be treated with Phasix™ Mesh in 15 sites across Europe. The primary outcome is Surgical Site Occurrence (SSO) including hematoma, seroma, infection, dehiscence and fistula formation (requiring intervention) through 3 months. Secondary outcomes include recurrence, infection and quality of life related outcomes after 24 months. Follow-up visits will be at drain removal (if drains were not placed, then on discharge or staple removal instead) and in the 1st, 3rd, 6th, 12th, 18th and 24th month after surgery. CONCLUSION: Based on evidence from this clinical study Depending on the results this clinical study will yield, Phasix™ Mesh may become a preferred treatment option in VHWG Grade 3 patients. TRIAL REGISTRATION: The trial was registered on March 25, 2016 on clinicaltrials.gov: NCT02720042
    corecore