277 research outputs found

    Optimal control of motorsport differentials

    Get PDF
    Modern motorsport limited slip differentials (LSD) have evolved to become highly adjustable, allowing the torque bias that they generate to be tuned in the corner entry, apex and corner exit phases of typical on-track manoeuvres. The task of finding the optimal torque bias profile under such varied vehicle conditions is complex. This paper presents a nonlinear optimal control method which is used to find the minimum time optimal torque bias profile through a lane change manoeuvre. The results are compared to traditional open and fully locked differential strategies, in addition to considering related vehicle stability and agility metrics. An investigation into how the optimal torque bias profile changes with reduced track-tyre friction is also included in the analysis. The optimal LSD profile was shown to give a performance gain over its locked differential counterpart in key areas of the manoeuvre where a quick direction change is required. The methodology proposed can be used to find both optimal passive LSD characteristics and as the basis of a semi-active LSD control algorithm

    Can the design of glove dispensing boxes influence glove contamination?

    Get PDF
    Background Few studies have explored the microbial contamination of glove boxes in clinical settings. The objective of this observational study was to investigate whether a new glove packaging system in which gloves are dispensed one by one vertically with the cuff-end first has lower levels of contamination on the gloves and on the surface around the box aperture compared to conventional horizontally dispensed glove boxes. Methods Seven participating sites were provided with vertical glove dispensing systems and conventional boxes. Before opening boxes, the surface around the aperture was sampled microbiologically to establish base-line levels of superficial contamination. Once the boxes were opened, the first pair of gloves in each box were sampled for viable bacteria. Thereafter, testing sites were visited on a weekly basis over a period of six weeks and the same microbiological assessments made. Results The surface surrounding the aperture of the modified dispenser boxes became significantly less contaminated than the conventional boxes (P < 0.001) with an average of 46.7% less contamination around the aperture. Overall, gloves from modified boxes showed significantly less colony-forming units contamination than gloves from conventional boxes (P < 0.001). Comparing all sites over the entire six-week period, modified dispensed gloves had 88.9% less bacterial contamination. Conclusion This simple improvement to glove box design reduces contamination of unused gloves. Such modifications could decrease the risk of microbial cross-transmission in settings that utilise gloves. However, such advantages do not substitute for strict hand-hygiene compliance and appropriate use of non-sterile, single-use gloves

    Cold atmospheric pressure plasma for treatment of chronic wounds: drug or medical device?

    Get PDF
    Objective: The use of cold atmospheric pressure plasma (CAPP) as a new therapeutic option to aid the healing of chronic wounds appears promising. Currently, uncertainty exists regarding their classification as medical device or medical drug. Because the classification of CAPP has medical, legal, and economic consequences as well as implications for the level of preclinical and clinical testing, the correct classification is not an academic exercise, but an ethical need. Method: A multidisciplinary team of physicians, surgeons, pharmacists, physicists and lawyers has analysed the physical and technical characteristics as well as legal conditions of the biological action of CAPP. Results: It was concluded that the mode of action of the locally generated CAPP, with its main active components being different radicals, is pharmacological and not physical in nature. Conclusion: Depending on the intended use, CAPP should be classified as a drug, which is generated by use of a medical device directly at the point of therapeutic application

    Prevalence of needle stick injuries among dental, nursing and midwifery students in Shiraz, Iran

    Get PDF
    Background: The risk of occupational exposure to blood borne pathogens (including hepatitis B, hepatitis C and HIV) via sharp injuries such as needle stick injuries (NSIs) among health care workers, especially dental, nursing and midwifery students is a challenging issue. Inadequate staff, lack of experience, insufficient training, duty overload and fatigue may lead to occupational sharp injuries. The aim of this prospective cross-sectional study was to evaluate the frequency of NSIs in Iranian dental, nursing, and midwifery students and their knowledge, attitude and practices regarding prevention of NSIs

    Septic hip abscess due to Fusobacterium nucleatum and Actinomyces turicensis in an immunocompetent SARS-CoV-2 positive patient

    Get PDF
    A 42-year-old man was referred to the Department of Orthopedic Surgery with pain over his right greater trochanter and signs of systemic infection. CT showed an enhanced mass in his gluteus maximus as well as gas in the biceps femoris over the underlying hip joint. Tissue biopsy yielded Fusobacterium nucleatum and Actinomyces turicensis. The patient was successfully treated for 6 weeks with amoxicillin/clavulanic acid 875mg/125mg and metronidazole 500mg

    Clinical Use of the Antiseptic Polihexanide for Genital Tract Infections

    Get PDF
    Background: In clinical practice, treatment of genital tract infections is based on administration of either antibiotics or antiseptics. While antibiotics may be applied systemically or topically, antiseptics may be applied only topically. In case of bacterial vaginosis (BV), antibiotic therapy may often be limited and side effects due to systemic administration may develop. Polihexanide (PHMB) is a promising option for the topical treatment of genital tract infections, in particular BV and vaginitis. Method: A systematic search for publications on the use of PHMB for the treatment of genital infections in two electronic databases was performed. Titles, abstracts and citations were imported into a reference database. Duplicates were removed and two reviewers assessed each identified publication separately. Results: Among a total of 204 references, 3 prospective randomized trials were identified. Two trials treated BV infections with PHMB in comparison to clindamycin as antibiotic standard therapy with no significant differences either in safety or in efficacy. The third controlled trial investigated the clinical efficacy of PHMB compared to placebo in the treatment of human papilloma virus. Patients treated with PHMB daily for up to 16-weeks showed significantly higher (52%) clearance of genital warts as compared to patients treated with placebo (4%). Conclusion: PHMB may be a clinically effective alternative for the treatment of BV and human papilloma virus. Although PHMB-based antiseptics are available since the late 90s, controlled trials to investigate its clinical potential for antiseptic treatment are scant. Clinical use of antiseptics for the treatment of infectious diseases should be explored and supported further

    Antimicrobial Efficacy of the Silver Wound Dressing Biatain Ag in a Disc Carrier Test Simulating Wound Secretion

    Get PDF
    Aim: The efficacy of antimicrobial compounds included in wound dressings has been determined using the quantitative suspension test according to EN 13727 before. However, as suspension tests are not an accurate reflection of the conditions under which wound antiseptics are used, it was investigated if a disc carrier test would yield results simulating practical conditions on wound surfaces. A silver-leaching foam wound dressing was used for evaluation of the disc carrier test method. Method: The disc carriers consisted of circular stainless-steel discs measuring 2 cm in diameter and 1.5 mm in thickness, complying with the requirements of EN 10088-2. Carriers were contaminated with Staphylococcus aureus, methicillin-resistant S. aureus or Pseudomonas aeruginosa, respectively, together with an artificial wound secretion and left to dry at room temperature for 30 min. The wound dressings being tested were placed on the discs for the length of the exposure time, and after neutralization by thioglycolate in phosphate-buffered saline the number of surviving test organisms was then counted. The logarithmic reduction factor was calculated from the difference between the initial inoculum and the number of recovered test organisms. Results: The disc carrier test allowed determination of an antimicrobial efficacy in a realistic setting. It also imposed more stringent requirements on efficacy over time than the quantitative suspension test. The silver foam wound dressing showed a time-dependent antimicrobial efficacy. After 24-hour application time, the reduction factors against S. aureus, P. aeruginosa and the methicillin-resistant S. aureus were 1.9 ± 0.15, 2.1 ± 0.14 and 3.1 ± 0.18, respectively. Conclusion: The disc carrier test was a useful method for testing the antimicrobial efficacy of a foam silver dressing. The antimicrobial dressing exhibited an antimicrobial effect after 3 h and achieved a reduction >2 log against the tested bacterial strains in the presence of a simulated wound secretion after 24 h

    On the Experimental Analysis of Integral Sliding Modes for Yaw Rate and Sideslip Control of an Electric Vehicle with Multiple Motors

    Get PDF
    With the advent of electric vehicles with multiple motors, the steady-state and transient cornering responses can be designed and implemented through the continuous torque control of the individual wheels, i.e., torque-vectoring or direct yaw moment control. The literature includes several papers on sliding mode control theory for torque-vectoring, but the experimental investigation is so far limited. More importantly, to the knowledge of the authors, the experimental comparison of direct yaw moment control based on sliding modes and typical controllers used for stability control in production vehicles is missing. This paper aims to reduce this gap by presenting and analyzing an integral sliding mode controller for concurrent yaw rate and sideslip control. A new driving mode, the Enhanced Sport mode, is proposed, inducing sustained high values of sideslip angle, which can be limited to a specified threshold. The system is experimentally assessed on a four-wheel-drive electric vehicle. The performance of the integral sliding mode controller is compared with that of a linear quadratic regulator during step steer tests. The results show that the integral sliding mode controller significantly enhances the tracking performance and yaw damping compared to the more conventional linear quadratic regulator based on an augmented singletrack vehicle model formulation. © 2018, The Korean Society of Automotive Engineers and Springer-Verlag GmbH Germany, part of Springer Natur

    On Optimal Two-Impulse Earth-Moon Transfers in a Four-Body Model

    Get PDF
    In this paper two-impulse Earth-Moon transfers are treated in the restricted four-body problem with the Sun, the Earth, and the Moon as primaries. The problem is formulated with mathematical means and solved through direct transcription and multiple shooting strategy. Thousands of solutions are found, which make it possible to frame known cases as special points of a more general picture. Families of solutions are defined and characterized, and their features are discussed. The methodology described in this paper is useful to perform trade-off analyses, where many solutions have to be produced and assessed
    corecore