240 research outputs found

    A Calorimetric Search on Double Beta Decay of 130Te

    Get PDF
    We report on the final results of a series of experiments on double decay of 130Te carried out with an array of twenty cryogenic detectors. The set-up is made with crystals of TeO2 with a total mass of 6.8 kg, the largest operating one for a cryogenic experiment. Four crystals are made with isotopically enriched materials: two in 128Te and two others in 130Te. The remaining ones are made with natural tellurium, which contains 31.7 % and 33.8 % 128Te and 130Te, respectively. The array was run under a heavy shield in the Gran Sasso Underground Laboratory at a depth of about 3500 m.w.e. By recording the pulses of each detector in anticoincidence with the others a lower limit of 2.1E23 years has been obtained at the 90 % C.L. on the lifetime for neutrinoless double beta decay of 130Te. In terms of effective neutrino mass this is the most restrictive limit in direct experiments, after those obtained with Ge diodes. Limits on other lepton violating decays of 130Te and on the neutrinoless double beta decay of 128Te to the ground state of 128Xe are also reported and discussed. An indication is presented for the two neutrino double beta decay of 130Te. Some consequences of the present results in the interpretation of geochemical experiments are discussed.Comment: 14 pages, 3 figures, 2 tables; more analysis details. Accepted for publication on Physics Letters

    Scintillating double beta decay bolometers

    Full text link
    We present the results obtained in the development of scintillating Double Beta Decay bolometers. Several Mo and Cd based crystals were tested with the bolometric technique. The scintillation light was measured through a second independent bolometer. A 140 g CdWO_4 crystal was run in a 417 h live time measurement. Thanks to the scintillation light, the alpha background is easily discriminated resulting in zero counts above the 2615 keV gamma line of Thallium 208. These results, combined with an extremely easy light detector operation, represent the first tangible proof demonstrating the feasibility of this kind of technique.Comment: 15 pages, 8 figure

    CUORE: A Cryogenic Underground Observatory for Rare Events

    Get PDF
    CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.Comment: 39 pages, 12 figures, submitted to NI

    SICANE: a Detector Array for the Measurement of Nuclear Recoil Quenching Factors using Monoenergetic Neutron Beam

    Get PDF
    SICANE is a neutron scattering multidetector facility for the determination of the quenching factor (ratio of the response to nuclear recoils and to electrons) of cryogenic detectors used in direct WIMP searches. Well collimated monoenergetic neutron beams are obtained with inverse (p,n) reactions. The facility is described, and results obtained for the quenching factors of scintillation in NaI(Tl) and of heat and ionization in Ge are presented.Comment: 30 pages, Latex, 11 figures. Submitted to NIM

    On the alpha activity of natural tungsten isotopes

    Full text link
    The indication for the alpha decay of 180-W with a half-life T1/2=1.1+0.8-0.4(stat)+-0.3(syst)x10^18 yr has been observed for the first time with the help of the super-low background 116-CdWO_4 crystal scintillators. In conservative approach the lower limit on half-life of 180-W has been established as T1/2>0.7x10^18 yr at 90% C.L. Besides, new T1/2 bounds were set for alpha decay of 182-W, 183-W, 184-W and 186-W at the level of 10^20 yr.Comment: 16 pages, 8 figures, accepted in Phys. Rev.

    A Cryogenic Underground Observatory for Rare Events: Cuore, an Update

    Get PDF
    CUORE is a proposed tightly packed array of 1000 TeO_{2} bolometers, each being a cube 5 cm on a side with a mass of 750 gms. The array consists of 25 vertical towers, arranged in a square, of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow- background searches for neutrinoless double beta decay of ^{130}Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals of various sizes (MIBETA) has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.Comment: in press: Nucl. Phys. of Russian Academy of Sc

    A linear, low-noise, low-power optocoupler amplifier for bolometric detectors

    Get PDF
    We present an optocoupler with di⁄erential inputs and balanced output, which was realized to make galvanic decoupling in a bolometric detector read-out chain. The circuit configuration incorporates a true di⁄erential optocoupled feedback, with low bias current in LEDs and photodiodes. Large Common Mode (CMRR) and Power Supply (PSRR) Rejection Ratio, low crossover distortion, high dynamic range, low noise and power dissipation have been achieved. ( 1998 Elsevier Science B.V. All rights reserved
    • 

    corecore