7 research outputs found

    Analysis and Design of Dynamic Password Management System in Banks

    Get PDF
    随着业务规模不断扩大,ATM集中管理中心的日常管理工作越来越多、越来越困难。迫切需要一套管理系统以提高效率、降低成本、规避风险。为此,专门针对ATM集中管理日常工作的需求,结合银行的实际需要,开发出一套自助设备集中管理系统,以提高ATM机的安全管理及控制。 动态密码电子锁的发展,实现了远程控制开锁、无须钥匙开关等便捷安全的开锁管理模式。将其应用于银行的ATM机之中,不仅可以将老式机械密码锁的双人繁琐开锁方式变成通过双人指纹验证系统自动识别配对的便捷方式,同时对开锁关锁记录、加钞记录、人员唯一要求都形成极大的完善。 动态密码电子锁管理系统实现通过集中远程控制开闭锁,管理人员能够预先或实时监控...As the business scale expanding, of the daily management work of the ATM centralized management center are getting more and more, harder and harder. The requirement of a set of management system is urgent, which aims at improving efficiency, reducing cost, and avoiding risk. Therefore, specially on account of the demand of ATM managing daily work centrally, and combining the actual requirement of ...学位:工程硕士院系专业:软件学院_工程硕士(软件工程)学号:X201123064

    Prediction of Energy Resolution in the JUNO Experiment

    Get PDF
    International audienceThis paper presents the energy resolution study in the JUNO experiment, incorporating the latest knowledge acquired during the detector construction phase. The determination of neutrino mass ordering in JUNO requires an exceptional energy resolution better than 3% at 1 MeV. To achieve this ambitious goal, significant efforts have been undertaken in the design and production of the key components of the JUNO detector. Various factors affecting the detection of inverse beta decay signals have an impact on the energy resolution, extending beyond the statistical fluctuations of the detected number of photons, such as the properties of liquid scintillator, performance of photomultiplier tubes, and the energy reconstruction algorithm. To account for these effects, a full JUNO simulation and reconstruction approach is employed. This enables the modeling of all relevant effects and the evaluation of associated inputs to accurately estimate the energy resolution. The study reveals an energy resolution of 2.95% at 1 MeV. Furthermore, the study assesses the contribution of major effects to the overall energy resolution budget. This analysis serves as a reference for interpreting future measurements of energy resolution during JUNO data taking. Moreover, it provides a guideline in comprehending the energy resolution characteristics of liquid scintillator-based detectors

    Measurement of integrated luminosity of data collected at 3.773 GeV by BESIII from 2021 to 2024*

    No full text

    Amplitude analysis of the decays D0π+ππ+πD^0\rightarrow\pi^+\pi^-\pi^+\pi^- and D0π+ππ0π0D^0\rightarrow\pi^+\pi^-\pi^0\pi0

    No full text

    Determination of the number of ψ(3686) events taken at BESIII

    No full text
    The number of ψ(3686) events collected by the BESIII detector during the 2021 run period is determined to be (2259.3±11.1)×106 by counting inclusive ψ(3686) hadronic events. The uncertainty is systematic and the statistical uncertainty is negligible. Meanwhile, the numbers of ψ(3686) events collected during the 2009 and 2012 run periods are updated to be (107.7±0.6)×106 and (345.4±2.6)×106, respectively. Both numbers are consistent with the previous measurements within one standard deviation. The total number of ψ(3686) events in the three data samples is (2712.4±14.3)×10^

    Measurement of integrated luminosity of data collected at 3.773 GeV by BESIII from 2021 to 2024

    No full text
    We present a measurement of the integrated luminosity e+e- of collision data collected by the BESIII detector at the BEPCII collider at a center-of-mass energy of Ecm = 3.773 GeV. The integrated luminosities of the datasets taken from December 2021 to June 2022, from November 2022 to June 2023, and from October 2023 to February 2024 were determined to be 4.995±0.019 fb-1, 8.157±0.031 fb-1, and 4.191±0.016 fb-1, respectively, by analyzing large angle Bhabha scattering events. The uncertainties are dominated by systematic effects, and the statistical uncertainties are negligible. Our results provide essential input for future analyses and precision measurements