15 research outputs found

    A branch current reallocation based energy balancing strategy for the modular multilevel matrix converter operating around equal frequency

    Get PDF
    The Modular multilevel matrix converter (M3C) is a promising topology for medium-voltage, high-power applications. Due to the modular structure, it is scalable, produces high quality output waveforms and can be fault tolerant. However, the M3C suffers from capacitor-voltage fluctuation if the output frequency is similar to the input frequency. This problem could limit the circuit’s application in the adjustable speed drives (ASD). This paper introduces a theoretical analysis in the phasor-domain to find the branch energy equilibrium point of the M3C when operating with equal input and output frequencies. On the basis of this equilibrium point, a branch current reallocation based energy balancing control method is proposed to equalize the energy stored in the nine converter branches. With this novel control method, the M3C can effectively overcome the capacitor voltage fluctuation without using balancing techniques based on common mode voltage or applying reactive power at the input side

    Behavior of three-phase inverters under grid faults explained from a geometric perspective

    Get PDF
    The aim of this work is to analyze the dynamic behavior of inverters powered by renewable energy sources (RES) operating under grid faults by means of a geometric point of view. To this purpose, a three-phase grid-connected inverter subject to voltage sags is analyzed. First, the mathematical equations that describe its electrical model under voltage sags are given in the complex form of the transformed Park components. Second, simulations results show the resemblance between the curve depicted by the transformed Park components of the injected currents in the complex plane and well-known geometric curves. Finally, the geometric-based approach is used to describe easily the dynamic behavior of grid-connected inverters under voltage sags. This new approach could be used to propose new control techniques to achieve fault ride-through (FRT) capability of three-phase inverters.Peer ReviewedObjectius de Desenvolupament Sostenible::11 - Ciutats i Comunitats SosteniblesObjectius de Desenvolupament Sostenible::7 - Energia Assequible i No ContaminantPostprint (published version

    Detailed quantitative comparison of half-bridge modular multilevel converter modelling methods

    Get PDF
    This paper presents a detailed comparison of different modelling methods of the half-bridge modular multilevel converter (HB-MMC), namely, switching function, Thevenin equivalent and averaged, considering both MMC implementations (large and reduced number of cells). The theoretical basis that underpins each modelling method are discussed. Offline PSCAD simulations are used to validate user-defined switching function and averaged MMC models against the Thevenin equivalent model provided in PSCAD library for accuracy, considering steady-state and dc fault conditions. Furthermore, the RTDS based real-time simulation results of the user-defined HB-MMC switching function model are validated against the above mentioned offline models, considering steady-state and dc short circuit fault operations. Simulation speed and efficiency of different offline HB-MMC models being studied in this paper are compared. From comprehensive corroboration of different HB-MMC models presented in this paper, it has been found that the averaged, switching function and Thevenin equivalent models produce practically identical results during steady-state and dc faults. In detailed offline and real-time simulation studies where fundamental and harmonic dynamics are of interest, switching function model is found to be faster and computational efficient compared to the Thevenin equivalent model

    A branch current reallocation based energy balancing strategy for the modular multilevel matrix converter operating around equal frequency

    Get PDF
    Modular multilevel matrix converter (M3C) is a promising topology for medium-voltage high-power applications. Due to the modular structure, it features easy scalability, high quality output waveforms and superior fault tolerance. However, M3C suffers serious capacitor-voltage fluctuation if the output frequency gets closer to the input frequency. This limits its use in the adjustable-speed-drive (ASD) applications. This paper introduces a theoretical analysis in phasor-domain to find the branch energy equilibrium point of M3C when operating around equal frequency. On the basis of this equilibrium point, a branch current reallocation based energy balancing control method is proposed to equalize the energy stored in the nine converter branches. With this novel control method, M3C can effectively overcome the capacitor voltage fluctuation with neither using common voltage nor applying reactive power at the input side

    Multi-pole voltage source converter HVDC transmission systems

    Get PDF
    This study connects several modular multilevel converters to form multi-pole voltage source converter highvoltage dc (VSC-HVDC) links which are suited for bulk power evacuation, with increased resiliency to ac and dc network faults. The proposed arrangements resemble symmetrical and asymmetrical HVDC links that can be used for bulk power transfer over long distances with reduced transmission losses, and for the creation of multi-terminal supergrids currently being promoted for transitional dc grids in Europe. The technical feasibility of the proposed systems is assessed using simulations on symmetrical and asymmetrical tri-pole VSC-HVDC links, including the case of permanent pole-to-ground dc faults

    Dual harmonic injection for reducing the sub-module capacitor voltage ripples of hybrid MMC

    Get PDF
    Reducing the capacitor voltage ripples of the half-bridge sub-modules (HBSM) and full-bridge sub-modules (FBSM) in a hybrid modular multilevel converter (MMC) is expected to reduce the capacitance, volume and costs. To address this issue, this paper proposes a dual harmonic injection method which injects the second harmonic circulating current and third order harmonic voltage into the conventional MMC control. Firstly, the mathematical model of the proposed control is established and analyzed. Then, the general strategy of determining the amplitude and phase angle of each injection component is proposed to suppress the fluctuations of the fundamental and double frequency instantaneous power. The proposed strategy can achieve the optimal power fluctuation suppression under various operating conditions, which also has the advantage of reducing the voltage fluctuation difference between HB and FB SMs. The correctness and effectiveness of the proposed strategy are verified in simulations in PSCAD/EMTDC

    Derivation of Voltage Source Multilevel Converter Topologies

    Get PDF

    Study and comparison of discontinuous modulation for modular multilevel converters in motor drive applications

    Get PDF
    Discontinuous modulation applied to modular multilevel converters is an effective method for reducing the capacitor voltage ripples. In this paper, the discontinuous modulation is adapted and used in a motor drive application. For proper operation of the converter, a new energy controller is presented, which is suitable for operation with nonsinusoidal reference signals. Experimental results comparing the discontinuous modulation with other techniques operating at low motor speeds are shown. The results demonstrate the effectiveness of the discontinuous modulation on reducing capacitor voltage ripples and power losses.Postprint (published version

    An optimal full frequency control strategy for the modular multilevel matrix converter based on predictive control

    Get PDF
    The modular multilevel matrix converter (M3C) is a promising topology for high-voltage high-power applications. Recent researches have proved its significant advantages for adjustable-speed motor drives compared with the back-to-back modular multilevel converter (MMC). However, the branch energy balancing in the M3C presents great challenge especially at critical-frequency points where the output frequency is close to zero or grid-side frequency. Generally, this balancing control depends on the appropriate injection of inner circulating currents and the common-mode voltage (CMV) whereas their values are hard to determine and optimize. In this paper, an optimization based predictive control method is proposed to calculate the required circulating currents and the CMV. The proposed method features a broad-frequency range balancing of capacitor-voltages and no reactive power in the grid side. For operation at critical-frequency points, there is no increase on branch voltage stresses and limited increase on branch current stresses. A downscaled M3C system with 27 cells is designed and experiment results with the R-L load and induction motor load are presented to verify the proposed control method

    Improved Two-level Voltage Source Converter for High-Voltage Direct Current Transmission Systems

    Get PDF
    this paper presents an improved two-level voltage source converter for dc transmission systems with relatively low rated power and dc operating voltage. Unlike conventional two-level converter, the presented converter employs two distributed cell capacitors per three-phase; thus, do not contribute any current when converter is blocked during dc short circuit fault as in modular multilevel converter case. The use of three-phase cells is proven to be beneficial because the arm currents do not contain 2nd order harmonic currents, and cell capacitors tend to be small as they only experience high-order harmonic current associated with the switching frequency. For the same rated dc link voltage and switching devices, the rated power of the improved two-level converter will be twice that of the conventional two-level converter. Average, switching function and electromagnetic transient simulation models of the improved two-level converter are discussed and validated against detailed switch model. The viability of the improved two-level converter for HVDC applications is examined, considering dc and ac short circuit faults. Besides, reduced complexity of the control and power circuit of the improved two-level converter, it has been found that its transient responses to ac and dc faults are similar to that of the modular multilevel converter