35 research outputs found

    Quantifying Forearm Muscle Activity during Wrist and Finger Movements by Means of Multi-Channel Electromyography.

    Get PDF
    The study of hand and finger movement is an important topic with applications in prosthetics, rehabilitation, and ergonomics. Surface electromyography (sEMG) is the gold standard for the analysis of muscle activation. Previous studies investigated the optimal electrode number and positioning on the forearm to obtain information representative of muscle activation and robust to movements. However, the sEMG spatial distribution on the forearm during hand and finger movements and its changes due to different hand positions has never been quantified. The aim of this work is to quantify 1) the spatial localization of surface EMG activity of distinct forearm muscles during dynamic free movements of wrist and single fingers and 2) the effect of hand position on sEMG activity distribution. The subjects performed cyclic dynamic tasks involving the wrist and the fingers. The wrist tasks and the hand opening/closing task were performed with the hand in prone and neutral positions. A sensorized glove was used for kinematics recording. sEMG signals were acquired from the forearm muscles using a grid of 112 electrodes integrated into a stretchable textile sleeve. The areas of sEMG activity have been identified by a segmentation technique after a data dimensionality reduction step based on Non Negative Matrix Factorization applied to the EMG envelopes. The results show that 1) it is possible to identify distinct areas of sEMG activity on the forearm for different fingers; 2) hand position influences sEMG activity level and spatial distribution. This work gives new quantitative information about sEMG activity distribution on the forearm in healthy subjects and provides a basis for future works on the identification of optimal electrode configuration for sEMG based control of prostheses, exoskeletons, or orthoses. An example of use of this information for the optimization of the detection system for the estimation of joint kinematics from sEMG is reported

    New developments in prosthetic arm systems

    Get PDF
    Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold - insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb functionality. This article is aimed at reviewing the latest state of the upper limb prosthetic market, offering insights on the accompanying technologies and techniques. We also examine the capabilities and features of some of academia’s flagship solutions and methods

    Human-centered Electric Prosthetic (HELP) Hand

    Get PDF
    Through a partnership with Indian non-profit Bhagwan Mahaveer Viklang Sahayata Samiti, we designed a functional, robust, and and low cost electrically powered prosthetic hand that communicates with unilateral, transradial, urban Indian amputees through a biointerface. The device uses compliant tendon actuation, a small linear servo, and a wearable garment outfitted with flex sensors to produce a device that, once placed inside a prosthetic glove, is anthropomorphic in both look and feel. The prosthesis was developed such that future groups can design for manufacturing and distribution in India

    Design and testing of a textile EMG sensor for prosthetic control

    Get PDF
    Nowadays, Electromyography (EMG) signals generated by the amputee’s residual limbs are widely used for the control of myoelectric prostheses, usually with the aid of pattern-recognition algorithms. Since myoelectric prostheses are wearable medical devices, the sensors that integrate them should be appropriate for the users’ daily life, meeting the requirements of lightness, flexibility, greater motion identification, and skin adaptability. Therefore, this study aims to design and test an EMG sensor for prosthetic control, focusing on aspects such as adjustability, lightness, precise and constant signal acquisition; and replacing the conventional components of an EMG sensor with textile materials. The proposed sensor was made with Shieldex Technik-tex P130 + B conductive knitted fabric, with 99% pure silver plating. EMG data acquisition was performed twice on three volunteers: one with the textile sensor, and other with a commercial sensor used in prosthetic applications. Overall, the textile and the commercial sensor presented total average Signal-to-Noise Ratio (SNR) values of 10.24 ± 5.45 dB and 11.74 ± 8.64 dB, respectively. The authors consider that the obtained results are promising and leave room for further improvements in future work, such as designing strategies to deal with known sources of noise contamination and to increase the adhesion to the skin. In sum, the results presented in this paper indicate that, with the appropriate improvements, the proposed textile sensor may have the potential of being used for myoelectric prosthetic control, which can be a more ergonomic and accessible alternative to the sensors that are currently used for controlling these devices.This work is financed by Project “Deus ex Machina”, NORTE-01-0145-FEDER-000026, funded by CCDRN, through Sistema de Apoio à Investigação Científica e Tecnológica (Projetos Estruturados I&D&I) of Programa Operacional Regional do Norte, from Portugal 2020 and by Project UID/CTM/00264/2019 of 2C2T –Centro de Ciência e TecnologiaTêxtil, funded by National Founds through FCT/MCTES

    Towards Natural Control of Artificial Limbs

    Get PDF
    The use of implantable electrodes has been long thought as the solution for a more natural control of artificial limbs, as these offer access to long-term stable and physiologically appropriate sources of control, as well as the possibility to elicit appropriate sensory feedback via neurostimulation. Although these ideas have been explored since the 1960’s, the lack of a long-term stable human-machine interface has prevented the utilization of even the simplest implanted electrodes in clinically viable limb prostheses.In this thesis, a novel human-machine interface for bidirectional communication between implanted electrodes and the artificial limb was developed and clinically implemented. The long-term stability was achieved via osseointegration, which has been shown to provide stable skeletal attachment. By enhancing this technology as a communication gateway, the longest clinical implementation of prosthetic control sourced by implanted electrodes has been achieved, as well as the first in modern times. The first recipient has used it uninterruptedly in daily and professional activities for over one year. Prosthetic control was found to improve in resolution while requiring less muscular effort, as well as to be resilient to motion artifacts, limb position, and environmental conditions.In order to support this work, the literature was reviewed in search of reliable and safe neuromuscular electrodes that could be immediately used in humans. Additional work was conducted to improve the signal-to-noise ratio and increase the amount of information retrievable from extraneural recordings. Different signal processing and pattern recognition algorithms were investigated and further developed towards real-time and simultaneous prediction of limb movements. These algorithms were used to demonstrate that higher functionality could be restored by intuitive control of distal joints, and that such control remains viable over time when using epimysial electrodes. Lastly, the long-term viability of direct nerve stimulation to produce intuitive sensory feedback was also demonstrated.The possibility to permanently and reliably access implanted electrodes, thus making them viable for prosthetic control, is potentially the main contribution of this work. Furthermore, the opportunity to chronically record and stimulate the neuromuscular system offers new venues for the prediction of complex limb motions and increased understanding of somatosensory perception. Therefore, the technology developed here, combining stable attachment with permanent and reliable human-machine communication, is considered by the author as a critical step towards more functional artificial limbs

    A hybrid haptic stimulation prosthetic wearable device to recover the missing sensation of the upper limb amputees

    Get PDF
    A hybrid haptic feedback stimulation system that is capable in sensing the contact pressure, the surface texture, and the temperature, simultaneously, was designed for a prosthetic hand to provide a tactile sensation to amputation patients. In addition, the haptic system was developed to enable the prosthetic’s users to implement withdrawal reflexes due to the thermal noxious stimulus in a quick manner. The re-sensation is achieved by non-invasively stimulating the skin of the patients’ residual limbs, based on the type and the level of tactile signals provided by the sensory system of the prostheses. Accordingly, three stages of design and development were performed to satisfy the research methodology. A vibrotactile prosthetic device, which is designed for the detection of contact pressure and surface texture in upper extremity, represents. While, the design of a novel wearable hybrid pressure-vibration haptic feedback stimulation device for conveying the tactile information regarding the contact pressure between the prosthetic hand and the grasped objects represents the second methodology stage. Lastly, the third stage was achieved by designing a novel hybrid pressure-vibration-temperature feedback stimulation system to provide a huge information regarding the prostheses environment to the users without brain confusing or requiring long pre-training. The main contribution of this work is the development and evaluation of the first step of a novel approach for a lightweight, 7 Degrees-Of-Freedom (DOF) tactile prosthetic arm to perform an effective as well as fast object manipulation and grasping. Furthermore, this study investigates the ability to convey the tactile information about the contact pressure, surface texture, and object temperature to the amputees with high identification accuracy by mean of using the designed hybrid pressure-vibration-temperature feedback wearable device. An evaluation of sensation and response has been conducted on forty healthy volunteers to evaluate the ability of the haptic system to stimulate the human nervous system. The results in term of Stimulus Identification Rate (SIR) show that all the volunteers were correctly able to discriminate the sensation of touch, start of touch, end of touch, and grasping objects. While 94%, 96%, 97%, and 95.24% of the entire stimuli were successfully identified by the volunteers during the experiments of slippage, pressure level, surface texture, and temperature, respectively. The position tracking controller system was designed to synchronize the movements of the volunteers’ elbow joints and the prosthetic’s elbow joint to record the withdrawal reflexes. The results verified the ability of the haptic system to excite the human brain at the abnormal noxious stimulus and enable the volunteers to perform a quick withdrawal reflex within 0.32 sec. The test results and the volunteers' response established evidence that amputees are able to recover their sense of the contact pressure, the surface texture, and the object temperature as well as to perform thermal withdrawal reflexes using the solution developed in this work

    Increasing the robustness of active upper limb prostheses

    Get PDF
    This thesis is based on my work done at the Institute for Neurorehabilitation Systems at the University Medical Center Goettingen. My work has been partially founded by German Ministry for Education and Research (BMBF) via the Bernstein Focus Neurotechnology (BFNT) Göttingen under grant number 1GQ0810 The local ethics committee approved all studies involving human subjects, and all subjects signed informed consents prior to their participation in the studies. The entire thesis has been originally written by me. Part of the materials used in this thesis have also been published in journals or conferences, where I am the first or corresponding author. All rights for re-use of previously published material were obtained. Reused figures and tables of IEEE publications are marked with © [Year] IEEE. Hereby I declare that I have written this thesis independently and with no other aids and sources than quoted

    A Review of Non-Invasive Haptic Feedback stimulation Techniques for Upper Extremity Prostheses

    Get PDF
    A sense of touch is essential for amputees to reintegrate into their social and work life. The design of the next generation of the prostheses will have the ability to effectively convey the tactile information between the amputee and the artificial limbs. This work reviews non-invasive haptic feedback stimulation techniques to convey the tactile information from the prosthetic hand to the amputee’s brain. Various types of actuators that been used to stimulate the patient’s residual limb for different types of artificial prostheses in previous studies have been reviewed in terms of functionality, effectiveness, wearability and comfort. The non-invasive hybrid feedback stimulation system was found to be better in terms of the stimulus identification rate of the haptic prostheses’ users. It can be conclude that integrating hybrid haptic feedback stimulation system with the upper limb prostheses leads to improving its acceptance among users
    corecore