22 research outputs found

    Myocardial effective transverse relaxation time T(2)* is elevated in hypertrophic cardiomyopathy: a 7.0 T magnetic resonance imaging study

    Get PDF
    Hypertrophic cardiomyopathy (HCM) is the most common genetic disease of the myocardium and bares the risk of progression to heart failure or sudden cardiac death. Identifying patients at risk remains an unmet need. Recognizing the dependence of microscopic susceptibility on tissue microstructure and on cardiac macromorphology we hypothesized that myocardial T2* might be altered in HCM patients compared to healthy controls. To test this hypothesis, myocardial T2*-mapping was conducted at 7.0 Tesla to enhance T2*-contrast. 2D CINE T2*-mapping was performed in healthy controls and HCM patients. To ensure that T2* is not dominated by macroscopic magnetic field inhomogeneities, volume selective B0 shimming was applied. T2* changes in the interventricular septum across the cardiac cycle were analyzed together with left ventricular radius and ventricular septal wall thickness. The results show that myocardial T2* is elevated throughout the cardiac cycle in HCM patients compared to healthy controls. A mean septal T2* = 13.7 ± 1.1 ms (end-systole: T2*,systole = 15.0 ± 2.1, end-diastole: T2*,diastole = 13.4 ± 1.3 ms, T2*,systole/T2*,diastole ratio = 1.12) was observed in healthy controls. For HCM patients a mean septal T2* = 17.4 ± 1.4 ms (end-systole: T2*,systole = 17.7 ± 1.2 ms, end-diastole: T2*,diastole = 16.2 ± 2.5 ms, T2*,systole/T2*,diastole ratio = 1.09) was found. Our preliminary results provide encouragement that assessment of T2* and its changes across the cardiac cycle may benefit myocardial tissue characterization in HCM

    Myocardial effective transverse relaxation time T(2)* correlates with left ventricular wall thickness: a 7.0 T MRI study

    Get PDF
    PURPOSE: Myocardial effective relaxation time T2* is commonly regarded as a surrogate for myocardial tissue oxygenation. However, it is legitimate to assume that there are multiple factors that influence T2*. To this end, this study investigates the relationship between T2* and cardiac macromorphology given by left ventricular (LV) wall thickness and left ventricular radius, and provides interpretation of the results in the physiological context. METHODS: High spatio-temporally resolved myocardial CINE T2* mapping was performed in 10 healthy volunteers using a 7.0 Tesla (T) full-body MRI system. Ventricular septal wall thickness, left ventricular inner radius, and T2* were analyzed. Macroscopic magnetic field changes were elucidated using cardiac phase-resolved magnetic field maps. RESULTS: Ventricular septal T2* changes periodically over the cardiac cycle, increasing in systole and decreasing in diastole. Ventricular septal wall thickness and T2* showed a significant positive correlation, whereas the inner LV radius and T2* were negatively correlated. The effect of macroscopic magnetic field gradients on T2* can be considered minor in the ventricular septum. CONCLUSION: Our findings suggest that myocardial T2* is related to tissue blood volume fraction. Temporally resolved T2* mapping could be beneficial for myocardial tissue characterization and for understanding cardiac (patho)physiology in vivo

    Quantifying MRI frequency shifts due to structures with anisotropic magnetic susceptibility using pyrolytic graphite sheet

    Get PDF
    Magnetic susceptibility is an important source of contrast in magnetic resonance imaging (MRI), with spatial variations in the susceptibility of tissue affecting both the magnitude and phase of the measured signals. This contrast has generally been interpreted by assuming that tissues have isotropic magnetic susceptibility, but recent work has shown that the anisotropic magnetic susceptibility of ordered biological tissues, such as myelinated nerves and cardiac muscle fibers, gives rise to unexpected image contrast. This behavior occurs because the pattern of field variation generated by microstructural elements formed from material of anisotropic susceptibility can be very different from that predicted by modelling the effects in terms of isotropic susceptibility. In MR images of tissue, such elements are manifested at a sub-voxel length-scale, so the patterns of field variation that they generate cannot be directly visualized. Here, we used pyrolytic graphite sheet which has a large magnetic susceptibility anisotropy to form structures of known geometry with sizes large enough that the pattern of field variation could be mapped directly using MRI. This allowed direct validation of theoretical expressions describing the pattern of field variation from anisotropic structures with biologically relevant shapes (slabs, spherical shells and cylindrical shells)

    Histological basis of laminar MRI patterns in high resolution images of fixed human auditory cortex

    Get PDF
    Functional magnetic resonance imaging (fMRI) studies of the auditory region of the temporal lobe would benefit from the availability of image contrast that allowed direct identification of the primary auditory cortex, as this region cannot be accurately located using gyral landmarks alone. Previous work has suggested that the primary area can be identified in magnetic resonance (MR) images because of its relatively high myelin content. However, MR images are also affected by the iron content of the tissue and in this study we sought to confirm that different MR image contrasts did correlate with the myelin content in the grey matter and were not primarily affected by iron content as is the case in the primary visual and somatosensory areas. By imaging blocks of fixed post-mortem cortex in a 7 Tesla scanner and then sectioning them for histological staining we sought to assess the relative contribution of myelin and iron to the grey matter contrast in the auditory region. Evaluating the image contrast in T2*-weighted images and quantitative R2* maps showed a reasonably high correlation between the myelin density of the grey matter and the intensity of the MR images. The correlation with T1-weighted phase sensitive inversion recovery (PSIR) images was better than with the previous two image types, and there were clearly differentiated borders between adjacent cortical areas in these images. A significant amount of iron was present in the auditory region, but did not seem to contribute to the laminar pattern of the cortical grey matter in MR images. Similar levels of iron were present in the grey and white matter and although iron was present in fibres within the grey matter, these fibres were fairly uniformly distributed across the cortex. Thus we conclude that T1- and T2*-weighted imaging sequences do demonstrate the relatively high myelin levels that are characteristic of the deep layers in primary auditory cortex and allow it and some of the surrounding areas to be reliably distinguished

    Observation of Angular Dependence of T1 in the Human White Matter at 3T

    Get PDF
    Background and Objective: Multiple factors including chemical composition and microstructure influence relaxivity of tissue water in vivo. We have quantified T1 in the human white mater (WM) together with diffusion tensor imaging to study a possible relationship between water T1, diffusional fractional anisotropy (FA) and fibre-to-field angle. Methods: An inversion recovery (IR) pulse sequence with 6 inversion times for T1 and a multi-band diffusion tensor sequence with 60 diffusion sensitizing gradient directions for FA and the fibre-to-field angle θ (between the principal direction of diffusion and B0) were used at 3 Tesla in 40 healthy subjects. T1 was assessed using the method previously applied to anisotropy of coherence lifetime to provide a heuristic demonstration as a surface plot of T1 as a function of FA and the angle θ. Results: Our data show that in the WM voxels with FA > 0.3 T1 becomes longer (i.e. 1/T1 = R1 slower) when fibre-to-field angle is 50–60°, approximating the magic angle of 54.7°. The longer T1 around the magic angle was found in a number of WM tracts independent of anatomy. S0 signal intensity, computed from IR fits, mirrored that of T1 being greater in the WM voxels when the fibre-to-field angle was 50–60°. Conclusions: The current data point to fibre-to-field-angle dependent T1 relaxation in WM as an indication of effects of microstructure on the longitudinal relaxation of water

    Fiber-orientation independent component of R2* obtained from single-orientation MRI measurements in simulations and a post-mortem human optic chiasm

    Get PDF
    The effective transverse relaxation rate (R2*) is sensitive to the microstructure of the human brain like the g-ratio which characterises the relative myelination of axons. However, the fibre-orientation dependence of R2* degrades its reproducibility and any microstructural derivative measure. To estimate its orientation-independent part (R2,iso*) from single multi-echo gradient-recalled-echo (meGRE) measurements at arbitrary orientations, a second-order polynomial in time model (hereafter M2) can be used. Its linear time-dependent parameter, β1, can be biophysically related to R2,iso* when neglecting the myelin water (MW) signal in the hollow cylinder fibre model (HCFM). Here, we examined the performance of M2 using experimental and simulated data with variable g-ratio and fibre dispersion. We found that the fitted β1 can estimate R2,iso* using meGRE with long maximum-echo time (TEmax ≈ 54 ms), but not accurately captures its microscopic dependence on the g-ratio (error 84%). We proposed a new heuristic expression for β1 that reduced the error to 12% for ex vivo compartmental R2 values. Using the new expression, we could estimate an MW fraction of 0.14 for fibres with negligible dispersion in a fixed human optic chiasm for the ex vivo compartmental R2 values but not for the in vivo values. M2 and the HCFM-based simulations failed to explain the measured R2*-orientation-dependence around the magic angle for a typical in vivo meGRE protocol (with TEmax ≈ 18 ms). In conclusion, further validation and the development of movement-robust in vivo meGRE protocols with TEmax ≈ 54 ms are required before M2 can be used to estimate R2,iso* in subjects
    corecore