3,809 research outputs found

    Examples of current radar technology and applications, chapter 5, part B

    Get PDF
    Basic principles and tradeoff considerations for SLAR are summarized. There are two fundamental types of SLAR sensors available to the remote sensing user: real aperture and synthetic aperture. The primary difference between the two types is that a synthetic aperture system is capable of significant improvements in target resolution but requires equally significant added complexity and cost. The advantages of real aperture SLAR include long range coverage, all-weather operation, in-flight processing and image viewing, and lower cost. The fundamental limitation of the real aperture approach is target resolution. Synthetic aperture processing is the most practical approach for remote sensing problems that require resolution higher than 30 to 40 m

    Correction of concentrated and distributed aberrations in medical ultrasound imaging

    Get PDF
    A method is presented for iterative correction of wave fields aberrated in a plane located at an arbitrary distance from an array transducer. The signals received from the transducer are processed by an inverse extrapolator in such a way that the output yields the transducer signals as if the transducer had been located directly at the position of the aberrator. For subsequent transmission cycles, the same inverse extrapolator is applied to delta pulses at time instants incorporating the time-reversed estimated aberration profile. The method can be applied to scattering and absorptive media, i.e. in medical conditions. The compensation of distributed aberration is also developed. It is shown that correction algorithms intended for concentrated aberrations can be used to reduce effects due to distributed aberrations; our conclusions with respect to the position of the equivalent concentrated aberrator differ from results reported in the literature. The method is demonstrated on realistic simulations of solid lesions, and cysts (voids) disturbed by intervening aberrating medi

    Split-beam echosounder observations of natural methane seep variability in the northern Gulf of Mexico

    Get PDF
    A method for positioning and characterizing plumes of bubbles from marine gas seeps using an 18 kHz scientific split-beam echo sounder (SBES) was developed and applied to acoustic observations of plumes of presumed methane gas bubbles originating at approximately 1400 m depth in the northern Gulf of Mexico. A total of 161 plume observations from 27 repeat surveys were grouped by proximity into 35 clusters of gas vent positions on the seafloor. Profiles of acoustic target strength per vertical meter of plume height were calculated with compensation for both the SBES beam pattern and the geometry of plume ensonification. These profiles were used as indicators of the relative fluxes and fates of gas bubbles acoustically observable at 18 kHz and showed significant variability between repeat observations at time intervals of 1 h–7.5 months. Active gas venting was observed during approximately one third of the survey passes at each cluster. While gas flux is not estimated directly in this study owing to lack of bubble size distribution data, repeat surveys at active seep sites showed variations in acoustic response that suggest relative changes in gas flux of up to 1 order of magnitude over time scales of hours. The minimum depths of acoustic plume observations at 18 kHz averaged 875 m and frequently coincided with increased amplitudes of acoustic returns in layers of biological scatterers, suggesting acoustic masking of the gas bubble plumes in these layers. Minimum plume depth estimates were limited by the SBES field of view in only five instances

    Robust Magnetic Resonance Imaging of Short T2 Tissues

    Get PDF
    Tissues with short transverse relaxation times are defined as ‘short T2 tissues’, and short T2 tissues often appear dark on images generated by conventional magnetic resonance imaging techniques. Common short T2 tissues include tendons, meniscus, and cortical bone. Ultrashort Echo Time (UTE) pulse sequences can provide morphologic contrasts and quantitative maps for short T2 tissues by reducing time-of-echo to the system minimum (e.g., less than 100 us). Therefore, UTE sequences have become a powerful imaging tool for visualizing and quantifying short T2 tissues in many applications. In this work, we developed a new Flexible Ultra Short time Echo (FUSE) pulse sequence employing a total of thirteen acquisition features with adjustable parameters, including optimized radiofrequency pulses, trajectories, choice of two or three dimensions, and multiple long-T2 suppression techniques. Together with the FUSE sequence, an improved analytical density correction and an auto-deblurring algorithm were incorporated as part of a novel reconstruction pipeline for reducing imaging artifacts. Firstly, we evaluated the FUSE sequence using a phantom containing short T2 components. The results demonstrated that differing UTE acquisition methods, improving the density correction functions and improving the deblurring algorithm could reduce the various artifacts, improve the overall signal, and enhance short T2 contrast. Secondly, we applied the FUSE sequence in bovine stifle joints (similar to the human knee) for morphologic imaging and quantitative assessment. The results showed that it was feasible to use the FUSE sequence to create morphologic images that isolate signals from the various knee joint tissues and carry out comprehensive quantitative assessments, using the meniscus as a model, including the mappings of longitudinal relaxation (T1) times, quantitative magnetization transfer parameters, and effective transverse relaxation (T2*) times. Lastly, we utilized the FUSE sequence to image the human skull for evaluating its feasibility in synthetic computed tomography (CT) generation and radiation treatment planning. The results demonstrated that the radiation treatment plans created using the FUSE-based synthetic CT and traditional CT data were able to present comparable dose calculations with the dose difference of mean less than a percent. In summary, this thesis clearly demonstrated the need for the FUSE sequence and its potential for robustly imaging short T2 tissues in various applications

    Feasibility of an Incoherent-scatter Radar Aboard the Space Shuttle

    Get PDF
    The results of a preliminary study to investigate the feasibility of conducting an incoherent scatter radar experiment on board the space shuttle are presented. The results indicate that such an experiment is technically feasible. The more difficult questions to answer are whether the system can be made flexible enough to justify the problems and costs involved. The design parameters and the tradeoffs that are available in the consideration of these questions are evaluated. Some of the more serious limitations pertain to: (1) the presence of ground clutter and F region auroral clutter; (2) available average power; (3) weight and volume associated with required antenna size, transmitter, and energy storage devices; and (4) antenna breakdown associated with high power transmitter problems

    Sensors for ceramic components in advanced propulsion systems: Summary of literature survey and concept analysis, task 3 report

    Get PDF
    The results of a literature survey and concept analysis related to sensing techniques for measuring of surface temperature, strain, and heat flux for (non-specific) ceramic materials exposed to elevated temperatures (to 2200 K) are summarized. Concepts capable of functioning in a gas turbine hot section environment are favored but others are reviewed also. Recommendation are made for sensor development in each of the three areas

    Design of an acoustically transparent pressure sensor for breast elastography

    Get PDF
    Breast cancer is the most commonly occurring cancer in women. Only in 2018 there were over 2 million new cases all over the world. The MURAB project, pursued at the University of Twente, has the aim to improving the breast biopsy procedure by reducing costs, patient discomfort and false negative rates. A 7-DOF KUKA robot arm steers an ultrasound transducer along a precise scanning trajectory to gather 3D volume image and stiffness values of the breast. Elasticity is the property of a body to be deformed and differs between tumors tissue and soft tissue. Elastography is a non-invasive technique in which the elasticity of a tissue is determined. The aim of this study is to design an acoustically transparent pressure sensor, mounted on the tip of the ultrasound probe, that can measure pressure differences across its surface during the scan, and assess elastographic measurements. The main idea is to use a pad of a characterized material and sequentially ultrasound images able to visualize the section of the pad and evaluate its deformation during time. The transmission of ultrasound waves into a solid depends on the mechanical characteristics of the material and on its physic state. In this work the relations between the acoustic properties and the mechanical behavior of an acoustically transparent pad are studied and evaluated

    Improving CT-guided transthoracic biopsy of mediastinal lesions by diffusion-weighted magnetic resonance imaging

    Get PDF
    OBJECTIVES: To evaluate the preliminary results obtained using diffusion-weighted magnetic resonance imaging and the apparent diffusion coefficient for planning computed tomography-guided biopsies of selected mediastinal lesions. METHODS: Eight patients with mediastinal lesions suspicious for malignancy were referred for computed tomography-guided biopsy. Diffusion-weighted magnetic resonance imaging and apparent diffusion coefficient measurement were performed to assist in biopsy planning with diffusion/computed tomography fused images. We selected mediastinal lesions that could provide discordant diagnoses depending on the biopsy site, including large heterogeneous masses, lesions associated with lung atelectasis or consolidation, lesions involving large mediastinal vessels and lesions for which the results of biopsy using other methods and histopathological examination were divergent from the clinical and radiological suspicion. RESULTS: In all cases, the biopsy needle was successfully directed to areas of higher signal intensity on diffusion-weighted sequences and the lowest apparent diffusion coefficient within the lesion (mean, 0.8 [range, 0.6-1.1]×10-3 mm2/s), suggesting high cellularity. All biopsies provided adequate material for specific histopathological diagnoses of four lymphomas, two sarcomas and two thymomas. CONCLUSION: Functional imaging tools, such as diffusion-weighted imaging and the apparent diffusion coefficient, are promising for implementation in noninvasive and imaging-guided procedures. However, additional studies are needed to confirm that mediastinal biopsy can be improved with these techniques
    corecore