9,015 research outputs found

    Induction flowmeter for dielectric fluids, experimental verification final report

    Get PDF
    Experimental verification of induction flow meter for use with dielectric fluid

    Aerometry instrumentation study Final report

    Get PDF
    Techniques and instruments for meteorological measurements in Mars and Venus atmosphere

    Fluid quantity gaging

    Get PDF
    A system for measuring the mass of liquid in a tank on orbit with 1 percent accuracy was developed and demonstrated. An extensive tradeoff identified adiabatic compression as the only gaging technique that is independent of gravity or its orientation, and of the size and distribution of bubbles in the tank. This technique is applicable to all Earth-storable and cryogenic liquids of interest for Space Station use, except superfluid helium, and can be applied to tanks of any size, shape, or internal structure. Accuracy of 0.2 percent was demonstrated in the laboratory, and a detailed analytical model was developed and verified by testing. A flight system architecture is presented that allows meeting the needs of a broad range of space fluid systems without custom development for each user

    Integrated control and health management. Orbit transfer rocket engine technology program

    Get PDF
    To insure controllability of the baseline design for a 7500 pound thrust, 10:1 throttleable, dual expanded cycle, Hydrogen-Oxygen, orbit transfer rocket engine, an Integrated Controls and Health Monitoring concept was developed. This included: (1) Dynamic engine simulations using a TUTSIM derived computer code; (2) analysis of various control methods; (3) Failure Modes Analysis to identify critical sensors; (4) Survey of applicable sensors technology; and, (5) Study of Health Monitoring philosophies. The engine design was found to be controllable over the full throttling range by using 13 valves, including an oxygen turbine bypass valve to control mixture ratio, and a hydrogen turbine bypass valve, used in conjunction with the oxygen bypass to control thrust. Classic feedback control methods are proposed along with specific requirements for valves, sensors, and the controller. Expanding on the control system, a Health Monitoring system is proposed including suggested computing methods and the following recommended sensors: (1) Fiber optic and silicon bearing deflectometers; (2) Capacitive shaft displacement sensors; and (3) Hot spot thermocouple arrays. Further work is needed to refine and verify the dynamic simulations and control algorithms, to advance sensor capabilities, and to develop the Health Monitoring computational methods

    A study of the thermoregulatory characteristics of a liquid-cooled garment with automatic temperature control based on sweat rate: Experimental investigation and biothermal man-model development

    Get PDF
    Experimental results for three subjects walking on a treadmill at exercise rates of up to 590 watts showed that thermal comfort could be maintained in a liquid cooled garment by using an automatic temperature controller based on sweat rate. The addition of head- and neck-cooling to an Apollo type liquid cooled garment increased its effectiveness and resulted in greater subjective comfort. The biothermal model of man developed in the second portion of the study utilized heat rates and exchange coefficients based on the experimental data, and included the cooling provisions of a liquid-cooled garment with automatic temperature control based on sweat rate. Simulation results were good approximations of the experimental results

    Development Of Digital Diagnostics And Measurement Tools For A High Heat Flux Thermal Loop

    Get PDF
    The ultimate goal of the present study is to enhance high heat flux removal and thermal management using spray cooling techniques. As a result, a two-phase heat transfer spray cooling loop was developed capable of removing high heat fluxes from a 0.0001 m2 (1 cm2) heated surface using water. The specific objectives were based on providing the necessary measuring tools and instrumentation for designing an efficient heat transfer loop diagnostics and measuring system. The instruments used consisted of the following measurement device types: flow rate, pressure, temperature, and void fraction. The selection of these devices involved preliminary analyses which were done in order to insure the measuring tool’s suitability for measuring quantities and parameters of interest. Two designs of capacitive void fraction sensors were considered. Over the course of the present study, some of the problems associated with the first void fraction sensor electrode design were identified and a new sensor electrode configuration was developed which provided a more sensitive and repeatable response. Data was collected covering a wide range of void fraction measurements ranging from 0 to 1 for two candidate fluids. The calibration data obtained was nonlinear for the full range of void fraction measurements. The present study also consisted of designing a thick film resistive high heat flux heater. The design and calibration procedures developed and used for each measuring tool is discussed further in detail

    Impedimetric antimicrobial peptide-based sensor for the early detection of periodontopathogenic bacteria

    Get PDF
    Peri-implantitis, an inflammation caused by biofilm formation, constitutes a major cause of implant failure in dentistry. Thus, the detection of bacteria at the early steps of biofilm growth represents a powerful strategy to prevent implant-related infections. In this regard, antimicrobial peptides (AMPs) can be used as effective biological recognition elements to selectively detect the presence of bacteria. Thus, the aim of the present study was to combine the use of miniaturized and integrated impedimetric transducers and AMPs to obtain biosensors with high sensitivity to monitor bacterial colonization. Streptococcus sanguinis, which is one of the most prevalent strains in the onset of periodontal diseases, was used as a model of oral bacteria. To this end, a potent AMP derived from human lactoferrin was synthesized and covalently immobilized on interdigitated electrode arrays (IDEA). X-ray photoelectron spectroscopy (XPS) and electrochemical impedance spectroscopy (EIS) were employed to optimize and characterize the method of immobilization. Noteworthy, the interaction of Streptococcus sanguinis with AMP-coated sensors provoked significant changes in the impedance spectra, which were univocally associated with the presence of bacteria, proving the feasibility of our method. In this regard, the developed biosensor permits to detect the presence of bacteria at concentrations starting from 101 colony forming units (CFU) mL-1 in KCl and from 102 CFU mL-1 in artificial saliva. Moreover, the system was devoid of cytotoxicity for human fibroblasts. These results indicate that the proposed approach can be effective in the detection of initial stages of biofilm formation, and may be useful in the early prevention and treatment of peri-implantitisPeer ReviewedPostprint (author's final draft

    Advances in Artificial and Biological Membranes: Mechanisms of Ionic Sensitivity, Ion-Sensor Designs and Applications for Ions Measurement

    Get PDF
    Ion-sensitive membrane-based sensors and ionic processes in bio-membranes are the focus of this book. The chapters are carefully chosen to characterize essential research trends, applications, and perspectives. They include solid contact ion-selective and reference electrodes and their electroanalytical behavior in zero and nonzero-current modes, planar and miniaturized multielectrode platforms, ion monitoring in extreme sports, and transmembrane transport through living endothelial cells to find the volume. This book is crowned by the consideration of a yet unexplored ion status in a mitochondrial matri

    Establishment of surface functionalization methods for spore-based biosensors and implementation into sensor technologies for aseptic food processing

    Get PDF
    Aseptic processing has become a popular technology to increase the shelf-life of packaged products and to provide non-contaminated goods to the consumers. In 2017, the global aseptic market was evaluated to be about 39.5 billion USD. Many liquid food products, like juice or milk, are delivered to customers every day by employing aseptic filling machines. They can operate around 12,000 ready-packaged products per hour (e.g., Pure-Pak® Aseptic Filling Line E-PS120A). However, they need to be routinely validated to guarantee contamination-free goods. The state-of-the-art methods to validate such machines are by means of microbiological analyses, where bacterial spores are used as test organisms because of their high resistance against several sterilants (e.g., gaseous hydrogen peroxide). The main disadvantage of the aforementioned tests is time: it takes at least 36-48 hours to get the results, i.e., the products cannot be delivered to customers without the validation certificate. Just in this example, in 36 hours, 432,000 products would be on hold for dispatchment; if more machines are evaluated, this number would linearly grow and at the end, the costs (only for waiting for the results) would be considerably high. For this reason, it is very valuable to develop new sensor technologies to overcome this issue. Therefore, the main focus of this thesis is on the further development of a spore-based biosensor; this sensor can determine the viability of spores after being sterilized with hydrogen peroxide. However, the immobilization strategy as well as its implementation on sensing elements and a more detailed investigation regarding its operating principle are missing. In this thesis, an immobilization strategy is developed to withstand harsh conditions (high temperatures, oxidizing environment) for spore-based biosensors applied in aseptic processing. A systematic investigation of the surface functionalization’s effect (e.g., hydroxylation) on sensors (e.g., electrolyte-insulator semiconductor (EIS) chips) is presented. Later on, organosilanes are analyzed for the immobilization of bacterial spores on different sensor surfaces. The electrical properties of the immobilization layer are studied as well as its resistance to a sterilization process with gaseous hydrogen peroxide. In addition, a sensor array consisting of a calorimetric gas sensor and a spore-based biosensor to measure hydrogen peroxide concentrations and the spores’ viability at the same time is proposed to evaluate the efficacy of sterilization processes
    • …
    corecore