1,065 research outputs found

    A practical approach to switching-loss reduction in a large-capacity static VAr compensator based on voltage-source inverters

    Get PDF
    This paper presents a simple method for reduction of switching and snubbing losses in a large-capacity static VAr compensator (SVC) consisting of multiple three-phase voltage-source square-wave inverters. The proposed method is characterized by a “commutation capacitor” connected in parallel with each switching device. The commutation capacitor allows the SVC to perform zero-voltage switching, and to reduce switching losses. The electric charge stored in the commutation capacitor is not dissipated, but regenerated to the DC-link capacitor. Moreover, a soft-starting method for the SVC is also presented to avoid forming a short circuit across the commutation capacitor during startup. Experimental results obtained from a 10 kVAr laboratory setup are shown to verify the viability of the operating principle of the commutation capacitor </p

    Advanced wind energy convertors using electronic power conversion.

    Get PDF
    SIGLEAvailable from British Library Document Supply Centre-DSC:DXN013000 / BLDSC - British Library Document Supply CentreGBUnited Kingdo

    Inductively coupled distributed static compensator for power quality analysis of distribution networks

    Get PDF
    In this research paper, an inductively coupled distributed static compensator (IC-DSTATCOM) for three phase three wire (3P3W) electric power distribution system (EPDS) is proposed. The contraction of power quality (PQ) was marked as a perilous droop mode bump into direct coupled distributed static compensator (DC-DSTATCOM). To regain the PQ, inductive coupling transformer is assisted in conjunction with DC-DSTATCOM. The system equivalent circuit of IC-DSTATCOM is accomplished by take into account of impedance of both transformer and DC-DSTATCOM to reveal the filtering technique. The filtering icos∅ mechanism is performed by following the generalized mathematical approach using MATLAB/Simulink. A case education is reviewed in detail to illustrate the performance of both DC-DSTATCOM and IC-DSTATCOM. The IC-DSTATCOM is amplified healthier as compared to other in terms of harmonics shortening, good power factor, load balancing, and potential regulation. To examine the effectiveness, simulation outputs of the IC-DSTATCOM with different PQ parameter indices are presented by following the benchmark measure of IEEE-2030-7-2017 and IEC-61000-1 system code

    Direct control of D-STATCOM based on 23-level cascaded multilevel inverter using harmonics elimination pulse width modulation

    Get PDF
    The distribution static synchronous compensator (D-STATCOM) is primarily used for solving power quality problems. Normally, the phase-shifted pulse width modulation (PS-PWM) switching is employed in conjunction with the direct control of the D-STATCOM. However, the PS-PWM exhibits high switching losses. To alleviate this problem, a direct control scheme for D-STATCOM based on the harmonic elimination PWM (HEPWM) switching is developed. Due to the difficulty in solving the equations for the HEPWM angles, no work is reported on the direct control for a multilevel voltage source inverter (MVSI) D-STATCOM with more than 15-levels. Thus, the main contribution of the work is the application of HEPWM for 23-level cascaded MVSI using a wide modulation index (MI) range (i.e. 5.40 – 8.15 p.u). The main motivation to utilize the high number of level is to allow for the output voltage of the D-STATCOM to be sufficiently high, thus avoiding the use of step-up transformer. Furthermore, the achieved MI keeps the total harmonic distortion of the MVSI output voltage below the IEEE 519 Standard (5%) over the entire operating range. The eleven HEPWM switching angles were computed using an optimization technique, known as the differential evolution. Since the angles were computed offline, they were retrieved from a look-up table whenever the output voltage of the MVSI was to be constructed. The HEPWM-based direct control was benchmarked against the popular PS-PWM using ± 6.5MVAr/11kV D-STATCOM modelled in MATLAB-Simulink and PLECS software. For the same switching frequency, the proposed HEPWM switching exhibited superior harmonic spectra, hence had lower losses. Furthermore, the size of the series coupling inductor can be reduced to at least half. Dynamically, the steady state value of the reactive current was reached in less than one mains cycle when a transition from the full inductive to full capacitive modes was imposed. In addition, the proposed D-STATCOM controller mitigated the swell and sag problems in less than one cycle

    Performance Analysis of Photovoltaic Fed Distributed Static Compensator for Power Quality Improvement

    Get PDF
    Owing to rising demand for electricity, shortage of fossil fuels, reliability issues, high transmission and distribution losses, presently many countries are looking forward to integrate the renewable energy sources into existing electricity grid. This kind of distributed generation provides power at a location close to the residential or commercial consumers with low transmission and distribution costs. Among other micro sources, solar photovoltaic (PV) systems are penetrating rapidly due to its ability to provide necessary dc voltage and decreasing capital cost. On the other hand, the distribution systems are confronting serious power quality issues because of various nonlinear loads and impromptu expansion. The power quality issues incorporate harmonic currents, high reactive power burden, and load unbalance and so on. The custom power device widely used to improve these power quality issues is the distributed static compensator (DSTATCOM). For continuous and effective compensation of power quality issues in a grid connected solar photovoltaic distribution system, the solar inverters are designed to operate as a DSTATCOM thus by increasing the efficiency and reducing the cost of the system. The solar inverters are interfaced with grid through an L-type or LCL-type ac passive filters. Due to the voltage drop across these passive filters a high amount of voltage is maintained across the dc-link of the solar inverter so that the power can flow from PV source to grid and an effective compensation can be achieved. So in the thesis a new topology has been proposed for PV-DSTATCOM to reduce the dc-link voltage which inherently reduces the cost and rating of the solar inverter. The new LCLC-type PV-DSTATCOM is implemented both in simulation and hardware for extensive study. From the obtained results, the LCLC-type PV-DSTATCOM found to be more effective than L-type and LCL-type PV-DSTATCOM. Selection of proper reference compensation current extraction scheme plays the most crucial role in DSTATCOM performance. This thesis describes three time-domain schemes viz. Instantaneous active and reactive power (p-q), modified p-q, and IcosΦ schemes. The objective is to bring down the source current THD below 5%, to satisfy the IEEE-519 Standard recommendations on harmonic limits. Comparative evaluation shows that, IcosΦ scheme is the best PV-DSTATCOM control scheme irrespective of supply and load conditions. In the view of the fact that the filtering parameters of the PV-DSTATCOM and gains of the PI controller are designed using a linearized mathematical model of the system. Such a design may not yield satisfactory results under changing operating conditions due to the complex, nonlinear and time-varying nature of power system networks. To overcome this, evolutionary algorithms have been adopted and an algorithm-specific control parameter independent optimization tool (JAYA) is proposed. The JAYA optimization algorithm overcomes the drawbacks of both grenade explosion method (GEM) and teaching learning based optimization (TLBO), and accelerate the convergence of optimization problem. Extensive simulation studies and real-time investigations are performed for comparative assessment of proposed implementation of GEM, TLBO and JAYA optimization on PV-DSTATCOM. This validates that, the PV-DSTATCOM employing JAYA offers superior harmonic compensation compared to other alternatives, by lowering down the source current THD to drastically small values. Another indispensable aspect of PV-DSTATCOM is that due to parameter variation and nonlinearity present in the system, the reference current generated by the reference compensation current extraction scheme get altered for a changing operating conditions. So a sliding mode controller (SMC) based p-q theory is proposed in the dissertation to reduce these effects. To validate the efficacy of the implemented sliding mode controller for the power quality improvement, the performance of the proposed system with both linear and non-linear controller are observed and compared by taking total harmonic distortion as performance index. From the obtained simulation and experimentation results it is concluded that the SMC based LCLC-type PV-DSTATCOM performs better in all critical operating conditions

    Mitigation of power quality issues due to high penetration of renewable energy sources in electric grid systems using three-phase APF/STATCOM technologies: a review.

    Get PDF
    This study summarizes an analytical review on the comparison of three-phase static compensator (STATCOM) and active power filter (APF) inverter topologies and their control schemes using industrial standards and advanced high-power configurations. Transformerless and reduced switch count topologies are the leading technologies in power electronics that aim to reduce system cost and offer the additional benefits of small volumetric size, lightweight and compact structure, and high reliability. A detailed comparison of the topologies, control strategies and implementation structures of grid-connected high-power converters is presented. However, reducing the number of power semiconductor devices, sensors, and control circuits requires complex control strategies. This study focuses on different topological devices, namely, passive filters, shunt and hybrid filters, and STATCOMs, which are typically used for power quality improvement. Additionally, appropriate control schemes, such as sinusoidal pulse width modulation (SPWM) and space vector PWM techniques, are selected. According to recent developments in shunt APF/STATCOM inverters, simulation and experimental results prove the effectiveness of APF/STATCOM systems for harmonic mitigation based on the defined limit in IEEE-519

    Active and reactive power flow management in parallel transmission lines using static series compensation (SSC) with energy storage

    Get PDF
    The power flow controlled in the electric power network is one of the main factors that affected the modern power systems development. The Static Series Compensatior with storage energy, is a FACTS powerful device that can control the active power flow control of multiple transmission lines branches. In this paper, a simulation model of power control using static series compensator with parallel transmission lines is presented.  The control system using adaptive neuro-fuzzy logic is proposed. The results show the ability of static series compensator with storage energy to control the flow of powers components "active and reactive power" in the controlled line and thus the overall power regulated between lines.

    Mitigation of Power Quality Problems Using Custom Power Devices: A Review

    Get PDF
    Electrical power quality (EPQ) in distribution systems is a critical issue for commercial, industrial and residential applications. The new concept of advanced power electronic based Custom Power Devices (CPDs) mainly distributed static synchronous compensator (D-STATCOM), dynamic voltage restorer (DVR) and unified power quality conditioner (UPQC) have been developed due to lacking the performance of traditional compensating devices to minimize power quality disturbances. This paper presents a comprehensive review on D-STATCOM, DVR and UPQC to solve the electrical power quality problems of the distribution networks. This is intended to present a broad overview of the various possible DSTATCOM, DVR and UPQC configurations for single-phase (two wire) and three-phase (three-wire and four-wire) networks and control strategies for the compensation of various power quality disturbances. Apart from this, comprehensive explanation, comparison, and discussion on D-STATCOM, DVR, and UPQC are presented. This paper is aimed to explore a broad prospective on the status of D-STATCOMs, DVRs, and UPQCs to researchers, engineers and the community dealing with the power quality enhancement. A classified list of some latest research publications on the topic is also appended for a quick reference

    Power factor-corrected transformerless three-phase PWM converter for UPS applications

    Get PDF
    This thesis describes the research of a new transformerless three phase PWM converter for uninterruptible power supplies (UPS) applications. The removal of the bulky three phase transformer in larger power UPS can provide a significant saving in weight and cost of the overall system. The converter consists of a new four-wire rectifier coupled with a four-wire inverter via a dc bus. The supply and load neutral may be connected together without any neutral current flowing into the utility regardless of the load on the inverter. This allows the load to be at the same potential as the utility. The rectifier, inverter and complete UPS and control system are described in detail and simulation results are used extensively to back up the theory. An experimental prototype of the four-wire rectifier provides further confirmation of the principles. A further proposal to digitize the system is given. This would reduce the size of the required control circuit and simplify the hardware requirements