5,675 research outputs found
PresenceSense: Zero-training Algorithm for Individual Presence Detection based on Power Monitoring
Non-intrusive presence detection of individuals in commercial buildings is
much easier to implement than intrusive methods such as passive infrared,
acoustic sensors, and camera. Individual power consumption, while providing
useful feedback and motivation for energy saving, can be used as a valuable
source for presence detection. We conduct pilot experiments in an office
setting to collect individual presence data by ultrasonic sensors, acceleration
sensors, and WiFi access points, in addition to the individual power monitoring
data. PresenceSense (PS), a semi-supervised learning algorithm based on power
measurement that trains itself with only unlabeled data, is proposed, analyzed
and evaluated in the study. Without any labeling efforts, which are usually
tedious and time consuming, PresenceSense outperforms popular models whose
parameters are optimized over a large training set. The results are interpreted
and potential applications of PresenceSense on other data sources are
discussed. The significance of this study attaches to space security, occupancy
behavior modeling, and energy saving of plug loads.Comment: BuildSys 201
Recommended from our members
iSEA: IoT-based smartphone energy assistant for prompting energy-aware behaviors in commercial buildings
Providing personalized energy-use information to individual occupants enables the adoption of energy-aware behaviors in commercial buildings. However, the implementation of individualized feedback still remains challenging due to the difficulties in collecting personalized data, tracking personal behaviors, and delivering personalized tailored information to individual occupants. Nowadays, the Internet of Things (IoT) technologies are used in a variety of applications including real-time monitoring, control, and decision-making due to the flexibility of these technologies for fusing different data streams. In this paper, we propose a novel IoT-based smartphone energy assistant (iSEA) framework which prompts energy-aware behaviors in commercial buildings. iSEA tracks individual occupants through tracking their smartphones, uses a deep learning approach to identify their energy usage, and delivers personalized tailored feedback to impact their usage. iSEA particularly uses an energy-use efficiency index (EEI) to understand behaviors and categorize them into efficient and inefficient behaviors. The iSEA architecture includes four layers: physical, cloud, service, and communication. The results of implementing iSEA in a commercial building with ten occupants over a twelve-week duration demonstrate the validity of this approach in enhancing individualized energy-use behaviors. An average of 34% energy savings was measured by tracking occupantsâ EEI by the end of the experimental period. In addition, the results demonstrate that commercial building occupants often ignore controlling over lighting systems at their departure events that leads to wasting energy during non-working hours. By utilizing the existing IoT devices in commercial buildings, iSEA significantly contributes to support research efforts into sensing and enhancing energy-aware behaviors at minimal costs
The design of an indirect method for the human presence monitoring in the intelligent building
This article describes the design and verification of the indirect method of predicting the course of CO2 concentration (ppm) from the measured temperature variables Tindoor (degrees C) and the relative humidity rH(indoor) (%) and the temperature T-outdoor (degrees C) using the Artificial Neural Network (ANN) with the Bayesian Regulation Method (BRM) for monitoring the presence of people in the individual premises in the Intelligent Administrative Building (IAB) using the PI System SW Tool (PI-Plant Information enterprise information system). The CA (Correlation Analysis), the MSE (Root Mean Squared Error) and the DTW (Dynamic Time Warping) criteria were used to verify and classify the results obtained. Within the proposed method, the LMS adaptive filter algorithm was used to remove the noise of the resulting predicted course. In order to verify the method, two long-term experiments were performed, specifically from February 1 to February 28, 2015, from June 1 to June 28, 2015 and from February 8 to February 14, 2015. For the best results of the trained ANN BRM within the prediction of CO2, the correlation coefficient R for the proposed method was up to 92%. The verification of the proposed method confirmed the possibility to use the presence of people of the monitored IAB premises for monitoring. The designed indirect method of CO2 prediction has potential for reducing the investment and operating costs of the IAB in relation to the reduction of the number of implemented sensors in the IAB within the process of management of operational and technical functions in the IAB. The article also describes the design and implementation of the FEIVISUAL visualization application for mobile devices, which monitors the technological processes in the IAB. This application is optimized for Android devices and is platform independent. The application requires implementation of an application server that communicates with the data server and the application developed. The data of the application developed is obtained from the data storage of the PI System via a PI Web REST API (Application Programming Integration) client.Web of Science8art. no. 2
Recommended from our members
System-level key performance indicators for building performance evaluation
Quantifying building energy performance through the development and use of key performance indicators (KPIs) is an essential step in achieving energy saving goals in both new and existing buildings. Current methods used to evaluate improvements, however, are not well represented at the system-level (e.g., lighting, plug-loads, HVAC, service water heating). Instead, they are typically only either measured at the whole building level (e.g., energy use intensity) or at the equipment level (e.g., chiller efficiency coefficient of performance (COP)) with limited insights for benchmarking and diagnosing deviations in performance of aggregated equipment that delivers a specific service to a building (e.g., space heating, lighting). The increasing installation of sensors and meters in buildings makes the evaluation of building performance at the system level more feasible through improved data collection. Leveraging this opportunity, this study introduces a set of system-level KPIs, which cover four major end-use systems in buildings: lighting, MELs (Miscellaneous Electric Loads, aka plug loads), HVAC (heating, ventilation, and air-conditioning), and SWH (service water heating), and their eleven subsystems. The system KPIs are formulated in a new context to represent various types of performance, including energy use, peak demand, load shape, occupant thermal comfort and visual comfort, ventilation, and water use. This paper also presents a database of system KPIs using the EnergyPlus simulation results of 16 USDOE prototype commercial building models across four vintages and five climate zones. These system KPIs, although originally developed for office buildings, can be applied to other building types with some adjustment or extension. Potential applications of system KPIs for system performance benchmarking and diagnostics, code compliance, and measurement and verification are discussed
Policy Design for Controlling Set-Point Temperature of ACs in Shared Spaces of Buildings
Air conditioning systems are responsible for the major percentage of energy
consumption in buildings. Shared spaces constitute considerable office space
area, in which most office employees perform their meetings and daily tasks,
and therefore the ACs in these areas have significant impact on the energy
usage of the entire office building. The cost of this energy consumption,
however, is not paid by the shared space users, and the AC's temperature
set-point is not determined based on the users' preferences. This latter factor
is compounded by the fact that different people may have different choices of
temperature set-points and sensitivities to change of temperature. Therefore,
it is a challenging task to design an office policy to decide on a particular
set-point based on such a diverse preference set. As a result, users are not
aware of the energy consumption in shared spaces, which may potentially
increase the energy wastage and related cost of office buildings. In this
context, this paper proposes an energy policy for an office shared space by
exploiting an established temperature control mechanism. In particular, we
choose meeting rooms in an office building as the test case and design a policy
according to which each user of the room can give a preference on the
temperature set-point and is paid for felt discomfort if the set-point is not
fixed according to the given preference. On the other hand, users who enjoy the
thermal comfort compensate the other users of the room. Thus, the policy
enables the users to be cognizant and responsible for the payment on the energy
consumption of the office space they are sharing, and at the same time ensures
that the users are satisfied either via thermal comfort or through incentives.
The policy is also shown to be beneficial for building management. Through
experiment based case studies, we show the effectiveness of the proposed
policy.Comment: Journal paper accepted in Energy & Buildings (Elsevier
Occupancy estimation in smart buildings using audio-processing techniques
In the past few years, several case studies have illustrated that the use of occupancy information in buildings leads to energy-efficient and low-cost HVAC operation. The widely presented techniques for occupancy estimation include temperature, humidity, CO2 concentration, image camera, motion sensor and passive infrared (PIR) sensor. So far little studies have been reported in literature to utilize audio and speech processing as indoor occupancy prediction technique. With rapid advances of audio and speech processing technologies, nowadays it is more feasible and attractive to integrate audio-based signal processing component into smart buildings. In this work, we propose to utilize audio processing techniques (i.e., speaker recognition and background audio energy estimation) to estimate room occupancy (i.e., the number of people inside a room). Theoretical analysis and simulation results demonstrate the accuracy and effectiveness of this proposed occupancy estimation technique. Based on the occupancy estimation, smart buildings will adjust the thermostat setups and HVAC operations, thus, achieving greater quality of service and drastic cost savings
Activities recognition and worker profiling in the intelligent office environment using a fuzzy finite state machine
Analysis of the office workersâ activities of daily working in an intelligent office environment can be used to optimize energy consumption and also office workersâ comfort. To achieve this end, it is essential to recognise office workersâ activities including short breaks, meetings and non-computer activities to allow an optimum control strategy to be implemented. In this paper, fuzzy finite state machines are used to model an office workerâs behaviour. The model will incorporate sensory data collected from the environment as the input and some pre-defined fuzzy states are used to develop the model. Experimental results are presented to illustrate the effectiveness of this approach. The activity models of different individual workers as inferred from the sensory devices can be distinguished. However, further investigation is required to create a more complete model
- âŚ