1,474 research outputs found

    Power quality disturbances assessment during unintentional islanding scenarios. A contribution to voltage sag studies

    Get PDF
    This paper presents a novel voltage sag topology that occurs during an unintentional islanding operation (IO) within a distribution network (DN) due to large induction motors (IMs). When a fault occurs, following the circuit breaker (CB) fault clearing, transiently, the IMs act as generators due to their remanent kinetic energy until the CB reclosing takes place. This paper primarily contributes to voltage sag characterization. Therefore, this novel topology is presented, analytically modelled and further validated. It is worth mentioning that this voltage sag has been identified in a real DN in which events have been recorded for two years. The model validation of the proposed voltage sag is done via digital simulations with a model of the real DN implemented in Matlab considering a wide range of scenarios. Both simulations and field measurements confirm the voltage sag analytical expression presented in this paper as well as exhibiting the high accuracy achieved in the three-phase model adopted.Postprint (published version

    An Adaptive Overcurrent Coordination Scheme to Improve Relay Sensitivity and Overcome Drawbacks due to Distributed Generation in Smart Grids

    Get PDF
    Distributed Generation (DG) brought new challenges for protection engineers since standard relay settings of traditional system may no longer function properly under increasing presence of DG. The extreme case is coordination loss between primary and backup relays. The directional overcurrent relay (DOCR) which is the most implemented protective device in the electrical network also suffers performance degradation in presence of DG. Therefore, this paper proposes the mitigation of DG impact on DOCR coordination employing adaptive protection scheme (APS) using differential evolution algorithm (DE) while improving overall sensitivity of relays . The impacts of DG prior and after the application of APS are presented based on interconnected 6 bus and IEEE 14 bus system. As a consequence, general sensitivity improvement and mitigation scheme is proposed

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Online disturbance prediction for enhanced availability in smart grids

    Get PDF
    A gradual move in the electric power industry towards Smart Grids brings new challenges to the system's efficiency and dependability. With a growing complexity and massive introduction of renewable generation, particularly at the distribution level, the number of faults and, consequently, disturbances (errors and failures) is expected to increase significantly. This threatens to compromise grid's availability as traditional, reactive management approaches may soon become insufficient. On the other hand, with grids' digitalization, real-time status data are becoming available. These data may be used to develop advanced management and control methods for a sustainable, more efficient and more dependable grid. A proactive management approach, based on the use of real-time data for predicting near-future disturbances and acting in their anticipation, has already been identified by the Smart Grid community as one of the main pillars of dependability of the future grid. The work presented in this dissertation focuses on predicting disturbances in Active Distributions Networks (ADNs) that are a part of the Smart Grid that evolves the most. These are distribution networks with high share of (renewable) distributed generation and with systems in place for real-time monitoring and control. Our main goal is to develop a methodology for proactive network management, in a sense of proactive mitigation of disturbances, and to design and implement a method for their prediction. We focus on predicting voltage sags as they are identified as one of the most frequent and severe disturbances in distribution networks. We address Smart Grid dependability in a holistic manner by considering its cyber and physical aspects. As a result, we identify Smart Grid dependability properties and develop a taxonomy of faults that contribute to better understanding of the overall dependability of the future grid. As the process of grid's digitization is still ongoing there is a general problem of a lack of data on the grid's status and especially disturbance-related data. These data are necessary to design an accurate disturbance predictor. To overcome this obstacle we introduce a concept of fault injection to simulation of power systems. We develop a framework to simulate a behavior of distribution networks in the presence of faults, and fluctuating generation and load that, alone or combined, may cause disturbances. With the framework we generate a large set of data that we use to develop and evaluate a voltage-sag disturbance predictor. To quantify how prediction and proactive mitigation of disturbances enhance availability we create an availability model of a proactive management. The model is generic and may be applied to evaluate the effect of proactive management on availability in other types of systems, and adapted for quantifying other types of properties as well. Also, we design a metric and a method for optimizing failure prediction to maximize availability with proactive approach. In our conclusion, the level of availability improvement with proactive approach is comparable to the one when using high-reliability and costly components. Following the results of the case study conducted for a 14-bus ADN, grid's availability may be improved by up to an order of magnitude if disturbances are managed proactively instead of reactively. The main results and contributions may be summarized as follows: (i) Taxonomy of faults in Smart Grid has been developed; (ii) Methodology and methods for proactive management of disturbances have been proposed; (iii) Model to quantify availability with proactive management has been developed; (iv) Simulation and fault-injection framework has been designed and implemented to generate disturbance-related data; (v) In the scope of a case study, a voltage-sag predictor, based on machine- learning classification algorithms, has been designed and the effect of proactive disturbance management on downtime and availability has been quantified

    A comparison framework for distribution system outage and fault location methods

    Get PDF
    Finding the location of faults in distribution networks has been a long standing problem for utility operators, and an interesting subject for researchers as well. In recent years, significant research efforts have been devoted to the development of methods for identification of the faulted area to assist utility operators in expediting service restoration, and consequently reducing outage time and relevant costs. Considering today's wide variety of distribution systems, a solution preferred for a specific system might be impractical for another one. This paper provides a comparison framework which classifies and reviews a relatively large number of different fault location and outage area location methods to serve as a guide to power system engineers and researchers to choose the best option based on their existing system and requirements. It also supports investigations on the challenging and unsolved problems to realize the fields of future studies and improvements. For each class of methods, a short description of the main idea and methodology is presented. Then, all the methods are discussed in detail presenting the key points, advantages, limitations, and requirements

    On-line Dynamic Security Assessment in Power Systems.

    Get PDF

    Redundancy-based approach for optimal number and location of power quality monitors in distribution systems with binary imperialist competitive approach

    Get PDF
    This article deals with optimal employment of power quality monitors (PQMs) in distribution networks on the basis of the idea of monitor reach area. The proposed model uses binary string, representing the installation mode of PQMs (Yes or No) in each bus of the network. In the current article, the binary version of the imperialist competitive algorithm (BICA) is used. Because it has the ability of enhancing the search potential with a rapid and secure convergence rate in the optimization process. The concept of redundancy is considered in this study. The overall cost function is formulated to optimize the two indices. The first one is the index of monitoring overlap, and the second one is the index of sag severity. Among the solutions that yield a full reachable power network and the objective function experiments the minimum value, the final optimal answer will be extracted through evaluating the redundancy. With an excellent redundancy with respect to other solutions, the buses of the system faced with faults are monitored more times, on an average. In the current research, DIGSILENT software is used in short-circuit analysis, whereas the BICA manages the optimization process. Simulation and comparison are performed on the 69-bus distribution system
    • …