262 research outputs found

    Quantitative geometric analysis of rib, costal cartilage and sternum from childhood to teenagehood

    Get PDF
    Better understanding of the effects of growth on children’s bones and cartilage is necessary for clinical and biomechanical purposes. The aim of this study is to define the 3D geometry of children’s rib cages: including sternum, ribs and costal cartilage. Three-dimensional reconstructions of 960 ribs, 518 costal cartilages and 113 sternebrae were performed on thoracic CT-scans of 48 children, aged four months to 15 years. The geometry of the sternum was detailed and nine parameters were used to describe the ribs and rib cages. A "costal index" was defined as the ratio between cartilage length and whole rib length to evaluate the cartilage ratio for each rib level. For all children, the costal index decreased from rib level one to three and increased from level three to seven. For all levels, the cartilage accounted for 45 to 60% of the rib length, and was longer for the first years of life. The mean costal index decreased by 21% for subjects over three years old compared to those under three (p<10-4). The volume of the sternebrae was found to be highly age dependent. Such data could be useful to define the standard geometry of the paediatric thorax and help to detect clinical abnormalities.Grant from the ANR (SECUR_ENFANT 06_0385) and supported by the GDR 2610 “Biomécanique des chocs” (CNRS/INRETS/GIE PSA Renault

    Thoracic Cartilage Ultrasound-CT Registration using Dense Skeleton Graph

    Full text link
    Autonomous ultrasound (US) imaging has gained increased interest recently, and it has been seen as a potential solution to overcome the limitations of free-hand US examinations, such as inter-operator variations. However, it is still challenging to accurately map planned paths from a generic atlas to individual patients, particularly for thoracic applications with high acoustic-impedance bone structures under the skin. To address this challenge, a graph-based non-rigid registration is proposed to enable transferring planned paths from the atlas to the current setup by explicitly considering subcutaneous bone surface features instead of the skin surface. To this end, the sternum and cartilage branches are segmented using a template matching to assist coarse alignment of US and CT point clouds. Afterward, a directed graph is generated based on the CT template. Then, the self-organizing map using geographical distance is successively performed twice to extract the optimal graph representations for CT and US point clouds, individually. To evaluate the proposed approach, five cartilage point clouds from distinct patients are employed. The results demonstrate that the proposed graph-based registration can effectively map trajectories from CT to the current setup for displaying US views through limited intercostal space. The non-rigid registration results in terms of Hausdorff distance (Mean±\pmSD) is 9.48±\pm0.27 mm and the path transferring error in terms of Euclidean distance is 2.21±\pm1.11 mm.Comment: Accepted by IROS2

    Development of the VHP-Female CAD model including Dynamic Breathing Sequence

    Get PDF
    Mathematics, physics, biology, and computer science are combined to create computational modeling, which studies the behaviors and reactions of complex biomedical problems. Modern biomedical research relies significantly on realistic computational human models or “virtual humans�. Relevant study areas utilizing computational human models include electromagnetics, solid mechanics, fluid dynamics, optics, ultrasound propagation, thermal propagation, and automotive safety research. These and other applications provide ample justification for the realization of the Visible Human Project® (VHP)-Female v. 4.0, a new platform-independent full body electromagnetic computational model. Along with the VHP-Female v. 4.0, a realistic and anatomically justified Dynamic Breathing Sequence is developed. The creation of such model is essential to the development of biomedical devices and procedures that are affected by the dynamics of human breathing, such as Magnetic Resonance Imaging and the calculation of Specific Absorption Rate. The model can be used in numerous application, including Breath-Detection Radar for human search and rescue

    Automatic 3D extraction of pleural plaques and diffuse pleural thickening from lung MDCT images

    Full text link
    Pleural plaques (PPs) and diffuse pleural thickening (DPT) are very common asbestos related pleural diseases (ARPD). They are currently identified non-invasively using medical imaging techniques. A fully automatic algorithm for 3D detection of calcified pleura in the diaphragmatic area and thickened pleura on the costal surfaces from multi detector computed tomography (MDCT) images has been developed and tested. The algorithm for detecting diaphragmatic pleura includes estimation of the diaphragm top surface in 3D and identifying those voxels at a certain vertical distance from the estimated diaphragm, and with intensities close to that of bone, as calcified pleura. The algorithm for detecting thickened pleura on the costal surfaces includes: estimation of the pleural costal surface in 3D, estimation of the centrelines of ribs and costal cartilages and the surfaces that they lie on, calculating the mean distance between the two surfaces, and identifying any space between the two surfaces whose distance exceeds the mean distance as thickened pleura. The accuracy and performance of the proposed algorithm was tested on 20 MDCT datasets from patients diagnosed with existing PPs and/or DPT and the results were compared against the ground truth provided by an experienced radiologist. Several metrics were employed and evaluations indicate high performance of both calcified pleura detection in the diaphragmatic area and thickened pleura on the costal surfaces. This work has made significant contributions to both medical image analysis and medicine. For the first time in medical image analysis, the approach uses other stable organs such as the ribs and costal cartilage, besides the lungs themselves, for referencing and landmarking in 3D. It also estimates fat thickness between the rib surface and pleura (which is usually very thin) and excludes it from the detected areas, when identifying the thickened pleura. It also distinguishes the calcified pleura attached to the rib(s), separates them in 3D and detects calcified pleura on the lung diaphragmatic surfaces. The key contribution to medicine is effective detection of pleural thickening of any size and recognition of any changes, however small. This could have a significant impact on managing patient risks

    Development of Human Body CAD Models and Related Mesh Processing Algorithms with Applications in Bioelectromagnetics

    Get PDF
    Simulation of the electromagnetic response of the human body relies heavily upon efficient computational CAD models or phantoms. The Visible Human Project (VHP)-Female v. 3.1 - a new platform-independent full-body electromagnetic computational model is revealed. This is a part of a significant international initiative to develop powerful computational models representing the human body. This model’s unique feature is full compatibility both with MATLAB and specialized FEM computational software packages such as ANSYS HFSS/Maxwell 3D and CST MWS. Various mesh processing algorithms such as automatic intersection resolver, Boolean operation on meshes, etc. used for the development of the Visible Human Project (VHP)-Female are presented. The VHP - Female CAD Model is applied to two specific low frequency applications: Transcranial Magnetic Stimulation (TMS) and Transcranial Direct Current Stimulation (tDCS). TMS and tDCS are increasingly used as diagnostic and therapeutic tools for numerous neuropsychiatric disorders. The development of a CAD model based on an existing voxel model of a Japanese pregnant woman is also presented. TMS for treatment of depression is an appealing alternative to drugs which are teratogenic for pregnant women. This CAD model was used to study fetal wellbeing during induced peak currents by TMS in two possible scenarios: (i) pregnant woman as a patient; and (ii) pregnant woman as an operator. An insight into future work and potential areas of research such as a deformable phantom, implants, and RF applications will be presented

    Applications of a Biomechanical Patient Model for Adaptive Radiation Therapy

    Get PDF
    Biomechanical patient modeling incorporates physical knowledge of the human anatomy into the image processing that is required for tracking anatomical deformations during adaptive radiation therapy, especially particle therapy. In contrast to standard image registration, this enforces bio-fidelic image transformation. In this thesis, the potential of a kinematic skeleton model and soft tissue motion propagation are investigated for crucial image analysis steps in adaptive radiation therapy. The first application is the integration of the kinematic model in a deformable image registration process (KinematicDIR). For monomodal CT scan pairs, the median target registration error based on skeleton landmarks, is smaller than (1.6 ± 0.2) mm. In addition, the successful transferability of this concept to otherwise challenging multimodal registration between CT and CBCT as well as CT and MRI scan pairs is shown to result in median target registration error in the order of 2 mm. This meets the accuracy requirement for adaptive radiation therapy and is especially interesting for MR-guided approaches. Another aspect, emerging in radiotherapy, is the utilization of deep-learning-based organ segmentation. As radiotherapy-specific labeled data is scarce, the training of such methods relies heavily on augmentation techniques. In this work, the generation of synthetically but realistically deformed scans used as Bionic Augmentation in the training phase improved the predicted segmentations by up to 15% in the Dice similarity coefficient, depending on the training strategy. Finally, it is shown that the biomechanical model can be built-up from automatic segmentations without deterioration of the KinematicDIR application. This is essential for use in a clinical workflow

    Reconstruction of Patient-Specific Bone Models from X-Ray Radiography

    Get PDF
    The availability of a patient‐specific bone model has become an increasingly invaluable addition to orthopedic case evaluation and planning [1]. Utilized within a wide range of specialized visualization and analysis tools, such models provide unprecedented wealth of bone shape information previously unattainable using traditional radiographic imaging [2]. In this work, a novel bone reconstruction method from two or more x‐ray images is described. This method is superior to previous attempts in terms of accuracy and repeatability. The new technique accurately models the radiological scene in a way that eliminates the need for expensive multi‐planar radiographic imaging systems. It is also flexible enough to allow for both short and long film imaging using standard radiological protocols, which makes the technology easily utilized in standard clinical setups

    Brain and Human Body Modeling

    Get PDF
    This open access book describes modern applications of computational human modeling with specific emphasis in the areas of neurology and neuroelectromagnetics, depression and cancer treatments, radio-frequency studies and wireless communications. Special consideration is also given to the use of human modeling to the computational assessment of relevant regulatory and safety requirements. Readers working on applications that may expose human subjects to electromagnetic radiation will benefit from this book’s coverage of the latest developments in computational modelling and human phantom development to assess a given technology’s safety and efficacy in a timely manner. Describes construction and application of computational human models including anatomically detailed and subject specific models; Explains new practices in computational human modeling for neuroelectromagnetics, electromagnetic safety, and exposure evaluations; Includes a survey of modern applications for which computational human models are critical; Describes cellular-level interactions between the human body and electromagnetic fields
    corecore