3,839 research outputs found
Dispersive Fourier Transformation for Versatile Microwave Photonics Applications
Abstract: Dispersive Fourier transformation (DFT) maps the broadband spectrum of an ultrashort optical pulse into a time stretched waveform with its intensity profile mirroring the spectrum using chromatic dispersion. Owing to its capability of continuous pulse-by-pulse spectroscopic measurement and manipulation, DFT has become an emerging technique for ultrafast signal generation and processing, and high-throughput real-time measurements, where the speed of traditional optical instruments falls short. In this paper, the principle and implementation methods of DFT are first introduced and the recent development in employing DFT technique for widespread microwave photonics applications are presented, with emphasis on real-time spectroscopy, microwave arbitrary waveform generation, and microwave spectrum sensing. Finally, possible future research directions for DFT-based microwave photonics techniques are discussed as well
e-SAFE: Secure, Efficient and Forensics-Enabled Access to Implantable Medical Devices
To facilitate monitoring and management, modern Implantable Medical Devices
(IMDs) are often equipped with wireless capabilities, which raise the risk of
malicious access to IMDs. Although schemes are proposed to secure the IMD
access, some issues are still open. First, pre-sharing a long-term key between
a patient's IMD and a doctor's programmer is vulnerable since once the doctor's
programmer is compromised, all of her patients suffer; establishing a temporary
key by leveraging proximity gets rid of pre-shared keys, but as the approach
lacks real authentication, it can be exploited by nearby adversaries or through
man-in-the-middle attacks. Second, while prolonging the lifetime of IMDs is one
of the most important design goals, few schemes explore to lower the
communication and computation overhead all at once. Finally, how to safely
record the commands issued by doctors for the purpose of forensics, which can
be the last measure to protect the patients' rights, is commonly omitted in the
existing literature. Motivated by these important yet open problems, we propose
an innovative scheme e-SAFE, which significantly improves security and safety,
reduces the communication overhead and enables IMD-access forensics. We present
a novel lightweight compressive sensing based encryption algorithm to encrypt
and compress the IMD data simultaneously, reducing the data transmission
overhead by over 50% while ensuring high data confidentiality and usability.
Furthermore, we provide a suite of protocols regarding device pairing,
dual-factor authentication, and accountability-enabled access. The security
analysis and performance evaluation show the validity and efficiency of the
proposed scheme
Exploiting Prior Knowledge in Compressed Sensing Wireless ECG Systems
Recent results in telecardiology show that compressed sensing (CS) is a
promising tool to lower energy consumption in wireless body area networks for
electrocardiogram (ECG) monitoring. However, the performance of current
CS-based algorithms, in terms of compression rate and reconstruction quality of
the ECG, still falls short of the performance attained by state-of-the-art
wavelet based algorithms. In this paper, we propose to exploit the structure of
the wavelet representation of the ECG signal to boost the performance of
CS-based methods for compression and reconstruction of ECG signals. More
precisely, we incorporate prior information about the wavelet dependencies
across scales into the reconstruction algorithms and exploit the high fraction
of common support of the wavelet coefficients of consecutive ECG segments.
Experimental results utilizing the MIT-BIH Arrhythmia Database show that
significant performance gains, in terms of compression rate and reconstruction
quality, can be obtained by the proposed algorithms compared to current
CS-based methods.Comment: Accepted for publication at IEEE Journal of Biomedical and Health
Informatic
ECG Signal Reconstruction on the IoT-Gateway and Efficacy of Compressive Sensing Under Real-time Constraints
Remote health monitoring is becoming indispensable, though, Internet of Things (IoTs)-based solutions have many implementation challenges, including energy consumption at the sensing node, and delay and instability due to cloud computing. Compressive sensing (CS) has been explored as a method to extend the battery lifetime of medical wearable devices. However, it is usually associated with computational complexity at the decoding end, increasing the latency of the system. Meanwhile, mobile processors are becoming computationally stronger and more efficient. Heterogeneous multicore platforms (HMPs) offer a local processing solution that can alleviate the limitations of remote signal processing. This paper demonstrates the real-time performance of compressed ECG reconstruction on ARM's big.LITTLE HMP and the advantages they provide as the primary processing unit of the IoT architecture. It also investigates the efficacy of CS in minimizing power consumption of a wearable device under real-time and hardware constraints. Results show that both the orthogonal matching pursuit and subspace pursuit reconstruction algorithms can be executed on the platform in real time and yield optimum performance on a single A15 core at minimum frequency. The CS extends the battery life of wearable medical devices up to 15.4% considering ECGs suitable for wellness applications and up to 6.6% for clinical grade ECGs. Energy consumption at the gateway is largely due to an active internet connection; hence, processing the signals locally both mitigates system's latency and improves gateway's battery life. Many remote health solutions can benefit from an architecture centered around the use of HMPs, a step toward better remote health monitoring systems.Peer reviewedFinal Published versio
Development of wireless bruxism monitoring device based on pressure-sensitive polymer composite
A wireless pressure sensing bite guard has been developed for monitoring the progress of bruxism (teeth grinding during sleep); as well as protecting the teeth from damages. For sensing the pressure effectively in the restricted space and hostile environment, a pressure sensitive polymer composite has been fabricated and encapsulated into a conventional bite guard which is safe for in-situ applications. The device is anticipated to give real-time data through wireless data transmission and to have a long working life (weeks). A microcontroller-based electronic circuit has been built in-house for data collection and transmission. A low power approach is configured to increase the working life of the device. This device is a useful tool for understanding and treating bruxism
- …