34 research outputs found
Demonstration of three‐dimensional indoor visible light positioning with multiple photodiodes and reinforcement learning
To provide high‐quality location‐based services in the era of the Internet of Things, visible light positioning (VLP) is considered a promising technology for indoor positioning. In this paper, we study a multi‐photodiodes (multi‐PDs) three‐dimensional (3D) indoor VLP system enhanced by reinforcement learning (RL), which can realize accurate positioning in the 3D space without any off-line training. The basic 3D positioning model is introduced, where without height information of the receiver, the initial height value is first estimated by exploring its relationship with the received signal strength (RSS), and then, the coordinates of the other two dimensions (i.e., X and Y in the horizontal plane) are calculated via trilateration based on the RSS. Two different RL processes, namely RL1 and RL2, are devised to form two methods that further improve horizontal and vertical positioning accuracy, respectively. A combination of RL1 and RL2 as the third proposed method enhances the overall 3D positioning accuracy. The positioning performance of the four presented 3D positioning methods, including the basic model without RL (i.e., Benchmark) and three RL based methods that run on top of the basic model, is evaluated experimentally. Experimental results verify that obviously higher 3D positioning accuracy is achieved by implementing any proposed RL based methods compared with the benchmark. The best performance is obtained when using the third RL based method that runs RL2 and RL1 sequentially. For the testbed that emulates a typical office environment with a height difference between the receiver and the transmitter ranging from 140 cm to 200 cm, an average 3D positioning error of 2.6 cm is reached by the best RL method, demonstrating at least 20% improvement compared to the basic model without performing RL
Design and analysis of collision reduction algorithms for LED-based indoor positioning with simulation and experimental validation
In this paper, we develop a low complexity indoor positioning system (IPS) and design a lightweight, low-cost, and wearable receiver for it. The accuracy of proximity-based LED IPS has been improved using overlap between LED beams but LED packets in the overlap region are subject to collisions. In this paper, we design collision handling algorithms for the IPS that considers building and lighting infrastructures. Mathematical analyses of the proposed algorithms are done and models for the probability of collisions are developed. The models, which are verified using simulations, are used to calculate the time required for position update called positioning time. Analysis of the positioning time is done for single and multiple receivers systems and validated with experimental measurements. Results show positioning error as low as 56 cm with a positioning time of about 300 ms for slotted unsynchronized systems and 500 ms for unslotted unsynchronized systems which makes the developed system pragmatic and appropriate for human positioning
A novel and adaptive angle diversity-based receiver for 6G underground mining VLC systems
Visible light communication (VLC) is considered an enabling technology for future 6G wireless systems. Among the many applications in which VLC systems are used, one of them is harsh environments such as Underground Mining (UM) tunnels. However, these environments are subject to degrading environmental and intrinsic challenges for optical links. Therefore, current research should focus on solutions to mitigate these problems and improve the performance of Underground Mining Visible Light Communication (UM-VLC) systems. In this context, this article presents a novel solution that involves an improvement to the Angle Diversity Receivers (ADRs) based on the adaptive orientation of the Photo-Diodes (PDs) in terms of the Received Signal Strength Ratio (RSSR) scheme. Specifically, this methodology is implemented in a hemidodecahedral ADR and evaluated in a simulated UM-VLC scenario. The performance of the proposed design is evaluated using metrics such as received power, user data rate, and bit error rate (BER). Furthermore, our approach is compared with state-of-the-art ADRs implemented with fixed PDs and with the Time of Arrival (ToA) reception method. An improvement of at least 60% in terms of the analyzed metrics compared to state-of-the-art solutions is obtained. Therefore, the numerical results demonstrate that the hemidodecahedral ADR, with adaptive orientation PDs, enhances the received optical signal. Furthermore, the proposed scheme improves the performance of the UM-VLC system due to its optimum adaptive angular positioning, which is completed according to the strongest optical received signal power. By improving the performance of the UM-VLC system, this novel method contributes to further consideration of VLC systems as potential and enabling technologies for future 6G deployments
Sistemas de posicionamento baseados em comunicação por luz para ambientes interiores
The demand for highly precise indoor positioning systems (IPSs) is growing
rapidly due to its potential in the increasingly popular techniques of the
Internet of Things, smart mobile devices, and artificial intelligence. IPS
becomes a promising research domain that is getting wide attention due to its
benefits in several working scenarios, such as, industries, indoor public
locations, and autonomous navigation. Moreover, IPS has a prominent
contribution in day-to-day activities in organizations such as health care
centers, airports, shopping malls, manufacturing, underground locations, etc.,
for safe operating environments. In indoor environments, both radio frequency
(RF) and optical wireless communication (OWC) based technologies could be
adopted for localization. Although the RF-based global positioning system,
such as, Global positioning system offers higher penetration rates with
reduced accuracy (i.e., in the range of a few meters), it does not work well in
indoor environments (and not at all in certain cases such as tunnels, mines,
etc.) due to the very weak signal and no direct access to the satellites. On the
other hand, the light-based system known as a visible light positioning (VLP)
system, as part of the OWC systems, uses the pre-existing light-emitting
diodes (LEDs)-based lighting infrastructure, could be used at low cost and
high accuracy compared with the RF-based systems. VLP is an emerging
technology promising high accuracy, high security, low deployment cost,
shorter time response, and low relative complexity when compared with RFbased
positioning.
However, in indoor VLP systems, there are some concerns such as,
multipath reflection, transmitter tilting, transmitter’s position, and orientation
uncertainty, human shadowing/blocking, and noise causing the increase in
the positioning error, thereby reducing the positioning accuracy of the system.
Therefore, it is imperative to capture the characteristics of different VLP
channel and properly model them for the dual purpose of illumination and
localization. In this thesis, firstly, the impact of transmitter tilting angles and
multipath reflections are studied and for the first time, it is demonstrated that
tilting the transmitter can be beneficial in VLP systems considering both line of
sight (LOS) and non-line of sight transmission paths. With the transmitters
oriented towards the center of the receiving plane, the received power level is
maximized due to the LOS components. It is also shown that the proposed
scheme offers a significant accuracy improvement of up to ~66% compared
with a typical non-tilted transmitter VLP. The effect of tilting the transmitter on
the lighting uniformity is also investigated and results proved that the
uniformity achieved complies with the European Standard EN 12464-1.
After that, the impact of transmitter position and orientation uncertainty on
the accuracy of the VLP system based on the received signal strength (RSS)
is investigated. Simulation results show that the transmitter uncertainties have
a severe impact on the positioning error, which can be leveraged through the
usage of more transmitters. Concerning a smaller transmitter’s position
epochs, and the size of the training set. It is shown that,
the ANN with Bayesian regularization outperforms the traditional RSS
technique using the non-linear least square estimation for all values of signal
to noise ratio.
Furthermore, a novel indoor VLP system is proposed based on support
vector machines and polynomial regression considering two different
multipath environments of an empty room and a furnished room. The results
show that, in an empty room, the positioning accuracy improvement for the
positioning error of 2.5 cm are 36.1, 58.3, and 72.2 % for three different
scenarios according to the regions’ distribution in the room. For the furnished
room, a positioning relative accuracy improvement of 214, 170, and 100 % is
observed for positioning error of 0.1, 0.2, and 0.3 m, respectively. Ultimately,
an indoor VLP system based on convolutional neural networks (CNN) is
proposed and demonstrated experimentally in which LEDs are used as
transmitters and a rolling shutter camera is used as receiver. A detection
algorithm named single shot detector (SSD) is used which relies on CNN (i.e.,
MobileNet or ResNet) for classification as well as position estimation of each
LED in the image. The system is validated using a real-world size test setup
containing eight LED luminaries. The obtained results show that the maximum
average root mean square positioning error achieved is 4.67 and 5.27 cm with
SSD MobileNet and SSD ResNet models, respectively. The validation results
show that the system can process 67 images per second, allowing real-time
positioning.A procura por sistemas de posicionamento interior (IPSs) de alta precisão tem
crescido rapidamente devido ao seu interesse nas técnicas cada vez mais
populares da Internet das Coisas, dispositivos móveis inteligentes e
inteligência artificial. O IPS tornou-se um domínio de pesquisa promissor que
tem atraído grande atenção devido aos seus benefícios em vários cenários de
trabalho, como indústrias, locais públicos e navegação autónoma. Além disso,
o IPS tem uma contribuição destacada no dia a dia de organizações, como,
centros de saúde, aeroportos, supermercados, fábricas, locais subterrâneos,
etc. As tecnologias baseadas em radiofrequência (RF) e comunicação óptica
sem fio (OWC) podem ser adotadas para localização em ambientes interiores.
Embora o sistema de posicionamento global (GPS) baseado em RF ofereça
taxas de penetração mais altas com precisão reduzida (ou seja, na faixa de
alguns metros), não funciona bem em ambientes interiores (e não funciona
bem em certos casos como túneis, minas, etc.) devido ao sinal muito fraco e
falta de acesso direto aos satélites. Por outro lado, o sistema baseado em luz
conhecido como sistema de posicionamento de luz visível (VLP), como parte
dos sistemas OWC, usa a infraestrutura de iluminação baseada em díodos
emissores de luz (LEDs) pré-existentes, é um sistemas de baixo custo e alta
precisão quando comprado com os sistemas baseados em RF. O VLP é uma
tecnologia emergente que promete alta precisão, alta segurança, baixo custo
de implantação, menor tempo de resposta e baixa complexidade relativa
quando comparado ao posicionamento baseado em RF.
No entanto, os sistemas VLP interiores, exibem algumas limitações, como, a
reflexão multicaminho, inclinação do transmissor, posição do transmissor e
incerteza de orientação, sombra/bloqueio humano e ruído, que têm como
consequência o aumento do erro de posicionamento, e consequente redução
da precisão do sistema. Portanto, é imperativo estudar as características dos
diferentes canais VLP e modelá-los adequadamente para o duplo propósito de
iluminação e localização. Esta tesa aborda, primeiramente, o impacto dos
ângulos de inclinação do transmissor e reflexões multipercurso no
desempenho do sistema de posicionamento. Demonstra-se que a inclinação
do transmissor pode ser benéfica em sistemas VLP considerando tanto a linha
de vista (LOS) como as reflexões. Com os transmissores orientados para o
centro do plano recetor, o nível de potência recebido é maximizado devido aos
componentes LOS. Também é mostrado que o esquema proposto oferece
uma melhoria significativa de precisão de até ~66% em comparação com um
sistema VLP de transmissor não inclinado típico. O efeito da inclinação do
transmissor na uniformidade da iluminação também é investigado e os
resultados comprovam que a uniformidade alcançada está de acordo com a
Norma Europeia EN 12464-1.
O impacto da posição do transmissor e incerteza de orientação na precisão
do sistema VLP com base na intensidade do sinal recebido (RSS) foi também investigado. Os resultados da simulação mostram que as incertezas do
transmissor têm um impacto severo no erro de posicionamento, que pode ser
atenuado com o uso de mais transmissores. Para incertezas de
posicionamento dos transmissores menores que 5 cm, os erros médios de
posicionamento são 23.3, 15.1 e 13.2 cm para conjuntos de 4, 9 e 16
transmissores, respetivamente. Enquanto que, para a incerteza de orientação
de um transmissor menor de 5°, os erros médios de posicionamento são 31.9,
20.6 e 17 cm para conjuntos de 4, 9 e 16 transmissores, respetivamente.
O trabalho da tese abordou a investigação dos aspetos de projeto de um
sistema VLP indoor no qual uma rede neuronal artificial (ANN) é utilizada para
estimativa de posicionamento considerando um canal multipercurso. O estudo
considerou a influência do ruído como indicador de desempenho para a
comparação entre diferentes abordagens de projeto. Três algoritmos de treino
de ANNs diferentes foram considerados, a saber, Levenberg-Marquardt,
regularização Bayesiana e algoritmos de gradiente conjugado escalonado,
para minimizar o erro de posicionamento no sistema VLP. O projeto da ANN foi
otimizado com base no número de neurónios nas camadas ocultas, no número
de épocas de treino e no tamanho do conjunto de treino. Mostrou-se que, a
ANN com regularização Bayesiana superou a técnica RSS tradicional usando
a estimação não linear dos mínimos quadrados para todos os valores da
relação sinal-ruído.
Foi proposto um novo sistema VLP indoor baseado em máquinas de vetores
de suporte (SVM) e regressão polinomial considerando dois ambientes
interiores diferentes: uma sala vazia e uma sala mobiliada. Os resultados
mostraram que, numa sala vazia, a melhoria da precisão de posicionamento
para o erro de posicionamento de 2.5 cm são 36.1, 58.3 e 72.2% para três
cenários diferentes de acordo com a distribuição das regiões na sala. Para a
sala mobiliada, uma melhoria de precisão relativa de posicionamento de 214,
170 e 100% é observada para erro de posicionamento de 0.1, 0.2 e 0.3 m,
respetivamente.
Finalmente, foi proposto um sistema VLP indoor baseado em redes neurais
convolucionais (CNN). O sistema foi demonstrado experimentalmente usando
luminárias LED como transmissores e uma camara com obturador rotativo
como recetor. O algoritmo de detecção usou um detector de disparo único
(SSD) baseado numa CNN pré configurada (ou seja, MobileNet ou ResNet)
para classificação. O sistema foi validado usando uma configuração de teste
de tamanho real contendo oito luminárias LED. Os resultados obtidos
mostraram que o erro de posicionamento quadrático médio alcançado é de
4.67 e 5.27 cm com os modelos SSD MobileNet e SSD ResNet,
respetivamente. Os resultados da validação mostram que o sistema pode
processar 67 imagens por segundo, permitindo o posicionamento em tempo
real.Programa Doutoral em Engenharia Eletrotécnic
NASA thesaurus. Volume 1: Hierarchical Listing
There are over 17,000 postable terms and nearly 4,000 nonpostable terms approved for use in the NASA scientific and technical information system in the Hierarchical Listing of the NASA Thesaurus. The generic structure is presented for many terms. The broader term and narrower term relationships are shown in an indented fashion that illustrates the generic structure better than the more widely used BT and NT listings. Related terms are generously applied, thus enhancing the usefulness of the Hierarchical Listing. Greater access to the Hierarchical Listing may be achieved with the collateral use of Volume 2 - Access Vocabulary and Volume 3 - Definitions
Reversed Three-Dimensional Visible Light Indoor Positioning Utilizing Annular Receivers with Multi-Photodiodes
Exploiting the increasingly wide use of light emitting diodes (LEDs) lighting, in this paper we propose a reversed indoor positioning system (IPS) based on LED visible light communication (VLC) in order to improve indoor positioning accuracy. Unlike other VLC positioning systems, we employ two annular receivers with multi-photodiodes installed on the ceiling to locate the persons who carry LEDs. The basic idea is using multi-photodiodes to calculate the angle while using the received signal strength (RSS) method to calculate the distance. The experiment results show that the effective positioning range of the proposed system is 1.8 m when the distance between two receivers is 1.2 m. Moreover, a positioning error less than 0.2 m can be achieved under the condition that the radius of the PIN circle is between 0.16 m and 0.2 m, and the distance of the transmitter-receiver plane is less than 1.8 m, which will be effective in practice