1,666 research outputs found
Geant4-based simulations of charge collection in CMOS Active Pixel Sensors
Geant4 is an object-oriented toolkit for the simulation of the interaction of particles and radiation with matter. It provides a snapshot of the state of a simulated particle in time, as it travels through a specified geometry. One important area of application is the modelling of radiation detector systems. Here, we extend the abilities of such modelling to include charge transport and sharing in pixelated CMOS Active Pixel Sensors (APSs); though similar effects occur in other pixel detectors. The CMOS APSs discussed were developed in the framework of the PRaVDA consortium to assist the design of custom sensors to be used in an energy-range detector for proton Computed Tomography (pCT). The development of ad-hoc classes, providing a charge transport model for a CMOS APS and its integration into the standard Geant4 toolkit, is described. The proposed charge transport model includes, charge generation, diffusion, collection, and sharing across adjacent pixels, as well as the full electronic chain for a CMOS APS. The proposed model is validated against experimental data acquired with protons in an energy range relevant for pCT
Recommended from our members
Radiation Damage in CMOS Image Sensors for Space Applications
The space radiation environment is damaging to silicon devices, such as Complementary Metal Oxide Semiconductor (CMOS) image sensors, affecting their performance over time or causing total failure.
The first part of this work investigates a Charge Coupled Device (CCD) style CMOS image sensor designed for TDI (Time Delay and Integration) mode imaging, a mode commonly used for Earth observation. Damage from high energy protons in the space environment decreases the Charge Transfer Efficiency (CTE) and increases the dark current of such devices. Experimental work on proton damaged devices is presented, showing the effects on CTE and dark current. The results are compared to a standard CCD by a simulation to take into account the different dimensions and operating conditions of the two devices.
The second part of this work describes an experimental campaign to determine the effects of process variations (namely the introduction of deep doping wells and the variation of epitaxial silicon thickness) on the rate of Single Event Latchup (SEL) in CMOS Active Pixel Sensor (APS) devices. SEL is a potentially destructive phenomenon which occurs in CMOS technology but not in CCDs. Test devices were subjected to heavy ion bombardement and SEL rates recorded for a range of heavy ions causing varying amounts of ionisation. A simulation using Technology Computer Aided Design (TCAD) was developed to predict the SEL rates due to heavy ions and to understand the characteristic shape of the SEL cross section vs. Linear Energy Transfer (LET) curves produced by SEL experiments. The simuation was carried out for structures representative of each of the design variants
Etude et caractérisation d'un capteur en silicium amorphe hydrogéné déposé sur circuit intégré pour la détection de particules et de rayonnements
Next generation experiments at the European laboratory of particle physics (CERN) require particle detector alternatives to actual silicon detectors. This thesis presents a novel detector technology, which is based on the deposition of a hydrogenated amorphous silicon sensor on top of an integrated circuit. Performance and limitations of this technology have been assessed for the first time in this thesis in the context of particle detectors. Specific integrated circuits have been designed and the detector segmentation, the interface sensor â chip and the sensor leakage current have been studied in details. The signal induced by the track of an ionizing particle in the sensor has been characterized and results on the signal speed, amplitude and on the sensor resistance to radiation are presented. The results are promising regarding the use of this novel technology for radiation detection, though limitations have been shown for particle physics application
Development of a miniaturised particle radiation monitor for Earth orbit
Geometry and algorithm design for a novel highly miniaturised radiation monitor (HMRM)
for spacecraft in medium Earth orbit are presented. The HMRM device comprises a telescopic configuration of application-specific active pixel sensors enclosed in a titanium shield, with an
estimated total mass of 52 g and volume of 15 cm3. The monitor is intended to provide real-time
dosimetry and identification of energetic charged particles in fluxes of up to 108 cm-2 s-1
(omnidirectional). Achieving this capability with such a small instrument could open new
prospects for radiation detection in space.
The methodology followed for the design and optimisation of the particle detector geometry
is explained and analysis algorithms - for real-time use within the monitor and for post-processing
reconstruction of spectra - are presented. Simulations with the Geant4 toolkit
are used to predict operational results in various Earth orbits. Early test results of a prototype
monitor, including calibration of the pixel sensors, are also reported.Open Acces
A review of advances in pixel detectors for experiments with high rate and radiation
The Large Hadron Collider (LHC) experiments ATLAS and CMS have established
hybrid pixel detectors as the instrument of choice for particle tracking and
vertexing in high rate and radiation environments, as they operate close to the
LHC interaction points. With the High Luminosity-LHC upgrade now in sight, for
which the tracking detectors will be completely replaced, new generations of
pixel detectors are being devised. They have to address enormous challenges in
terms of data throughput and radiation levels, ionizing and non-ionizing, that
harm the sensing and readout parts of pixel detectors alike. Advances in
microelectronics and microprocessing technologies now enable large scale
detector designs with unprecedented performance in measurement precision (space
and time), radiation hard sensors and readout chips, hybridization techniques,
lightweight supports, and fully monolithic approaches to meet these challenges.
This paper reviews the world-wide effort on these developments.Comment: 84 pages with 46 figures. Review article.For submission to Rep. Prog.
Phy
Ultrafast Radiographic Imaging and Tracking: An overview of instruments, methods, data, and applications
Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art
ionizing particle and light sources to experimentally study sub-nanosecond
dynamic processes in physics, chemistry, biology, geology, materials science
and other fields. These processes, fundamental to nuclear fusion energy,
advanced manufacturing, green transportation and others, often involve one mole
or more atoms, and thus are challenging to compute by using the first
principles of quantum physics or other forward models. One of the central
problems in U-RadIT is to optimize information yield through, e.g.
high-luminosity X-ray and particle sources, efficient imaging and tracking
detectors, novel methods to collect data, and large-bandwidth online and
offline data processing, regulated by the underlying physics, statistics, and
computing power. We review and highlight recent progress in: a.) Detectors; b.)
U-RadIT modalities; c.) Data and algorithms; and d.) Applications.
Hardware-centric approaches to U-RadIT optimization are constrained by detector
material properties, low signal-to-noise ratio, high cost and long development
cycles of critical hardware components such as ASICs. Interpretation of
experimental data, including comparisons with forward models, is frequently
hindered by sparse measurements, model and measurement uncertainties, and
noise. Alternatively, U-RadIT makes increasing use of data science and machine
learning algorithms, including experimental implementations of compressed
sensing. Machine learning and artificial intelligence approaches, refined by
physics and materials information, may also contribute significantly to data
interpretation, uncertainty quantification and U-RadIT optimization.Comment: 51 pages, 31 figures; Overview of ultrafast radiographic imaging and
tracking as a part of ULITIMA 2023 conference, Mar. 13-16,2023, Menlo Park,
CA, US
Recommended from our members
Characterisation of CMOS APS Technologies for Space Applications
In recent years, the performance of scientific CMOS active pixel sensors has been improved to the point that it is now approaching that of the current silicon sensor of choice, CCDs. For some applications, CMOS APSs is believed to present significant advantages over CCDs, such as improved radiation hardness. In this work, the effect of radiation damage on a ‘baseline’ commercial APS, e2v technologies’ Jade APS, is characterised in response to gamma, proton and heavy ion irradiation. Specific performance problems encountered during this radiation characterisation, such as dark current non-uniformity under gamma irradiation, random telegraph signals under proton irradiation, and single event effects under heavy ion irradiation are described and analyzed. The X-ray spectroscopic imaging performance of the device is measured and compared to the Ocean Colour Imager APS test array showing progress towards a high frame rate spectroscopic X-ray imager for space science. The implications of these results for using similar devices in space applications are considered. Furthermore, possible novel techniques for measuring inter-pixel responsivity non-uniformity, heavy ion detection and spectroscopy, and measuring the dynamics of radiation-induced trap formation are discussed
Technology advancement of the CCD201-20 EMCCD for the WFIRST coronagraph instrument: sensor characterization and radiation damage
The Wide Field InfraRed Survey Telescope-Astrophysics Focused Telescope Asset (WFIRST-AFTA) mission is a 2.4-m class space telescope that will be used across a swath of astrophysical research domains. JPL will provide a high-contrast imaging coronagraph instrument—one of two major astronomical instruments. In order to achieve the low noise performance required to detect planets under extremely low flux conditions, the electron multiplying charge-coupled device (EMCCD) has been baselined for both of the coronagraph’s sensors—the imaging camera and integral field spectrograph. JPL has established an EMCCD test laboratory in order to advance EMCCD maturity to technology readiness level-6. This plan incorporates full sensor characterization, including read noise, dark current, and clock-induced charge. In addition, by considering the unique challenges of the WFIRST space environment, degradation to the sensor’s charge transfer efficiency will be assessed, as a result of damage from high-energy particles such as protons, electrons, and cosmic rays. Science-grade CCD201-20 EMCCDs have been irradiated to a proton fluence that reflects the projected WFIRST orbit. Performance degradation due to radiation displacement damage is reported, which is the first such study for a CCD201-20 that replicates the WFIRST conditions. In addition, techniques intended to identify and mitigate radiation-induced electron trapping, such as trap pumping, custom clocking, and thermal cycling, are discussed
- …