362 research outputs found

    Short-range ultrasonic communications in air using quadrature modulation

    Get PDF
    A study has been undertaken of ultrasonic communications methods in air, using a quadrature modulation method. Simulations were first performed to establish the likely performance of quadrature phase shift keying over the limited bandwidth available in an ultrasonic system. Quadrature phase shift keying modulation was then implemented within an experimental communication system, using capacitive ultrasonic sources and receivers. The results show that such a system is feasible in principle for communications over distances of several meters, using frequencies in the 200 to 400 kHz range

    医用超音波における散乱体分布の高解像かつ高感度な画像化に関する研究

    Get PDF
    Ultrasound imaging as an effective method is widely used in medical diagnosis andNDT (non-destructive testing). In particular, ultrasound imaging plays an important role in medical diagnosis due to its safety, noninvasive, inexpensiveness and real-time compared with other medical imaging techniques. However, in general the ultrasound imaging has more speckles and is low definition than the MRI (magnetic resonance imaging) and X-ray CT (computerized tomography). Therefore, it is important to improve the ultrasound imaging quality. In this study, there are three newproposals. The first is the development of a high sensitivity transducer that utilizes piezoelectric charge directly for FET (field effect transistor) channel control. The second is a proposal of a method for estimating the distribution of small scatterers in living tissue using the empirical Bayes method. The third is a super-resolution imagingmethod of scatterers with strong reflection such as organ boundaries and blood vessel walls. The specific description of each chapter is as follows: Chapter 1: The fundamental characteristics and the main applications of ultrasound are discussed, then the advantages and drawbacks of medical ultrasound are high-lighted. Based on the drawbacks, motivations and objectives of this study are stated. Chapter 2: To overcome disadvantages of medical ultrasound, we advanced our studyin two directions: designing new transducer improves the acquisition modality itself, onthe other hand new signal processing improve the acquired echo data. Therefore, the conventional techniques related to the two directions are reviewed. Chapter 3: For high performance piezoelectric, a structure that enables direct coupling of a PZT (lead zirconate titanate) element to the gate of a MOSFET (metal-oxide semiconductor field-effect transistor) to provide a device called the PZT-FET that acts as an ultrasound receiver was proposed. The experimental analysis of the PZT-FET, in terms of its reception sensitivity, dynamic range and -6 dB reception bandwidth have been investigated. The proposed PZT-FET receiver offers high sensitivity, wide dynamic range performance when compared to the typical ultrasound transducer. Chapter 4: In medical ultrasound imaging, speckle patterns caused by reflection interference from small scatterers in living tissue are often suppressed by various methodologies. However, accurate imaging of small scatterers is important in diagnosis; therefore, we investigated influence of speckle pattern on ultrasound imaging by the empirical Bayesian learning. Since small scatterers are spatially correlated and thereby constitute a microstructure, we assume that scatterers are distributed according to the AR (auto regressive) model with unknown parameters. Under this assumption, the AR parameters are estimated by maximizing the marginal likelihood function, and the scatterers distribution is estimated as a MAP (maximum a posteriori) estimator. The performance of our method is evaluated by simulations and experiments. Through the results, we confirmed that the band limited echo has sufficient information of the AR parameters and the power spectrum of the echoes from the scatterers is properly extrapolated. Chapter 5: The medical ultrasound imaging of strong reflectance scatterers based on the MUSIC algorithm is the main subject of Chapter 5. Previously, we have proposed a super-resolution ultrasound imaging based on multiple TRs (transmissions/receptions) with different carrier frequencies called SCM (super resolution FM-chirp correlation method). In order to reduce the number of required TRs for the SCM, the method has been extended to the SA (synthetic aperture) version called SA-SCM. However, since super-resolution processing is performed for each line data obtained by the RBF (reception beam forming) in the SA-SCM, image discontinuities tend to occur in the lateral direction. Therefore, a new method called SCM-weighted SA is proposed, in this version the SCM is performed on each transducer element, and then the SCM result is used as the weight for RBF. The SCM-weighted SA can generate multiple B-mode images each of which corresponds to each carrier frequency, and the appropriate low frequency images among them have no grating lobes. For a further improvement, instead of simple averaging, the SCM applied to the result of the SCM-weighted SA for all frequencies again, which is called SCM-weighted SA-SCM. We evaluated the effectiveness of all the methods by simulations and experiments. From the results, it can be confirmed that the extension of the SCM framework can help ultrasound imaging reduce grating lobes, perform super-resolution and better SNR(signal-to-noise ratio). Chapter 6: A discussion of the overall content of the thesis as well as suggestions for further development together with the remaining problems are summarized.首都大学東京, 2019-03-25, 博士(工学)首都大学東

    Innovations in Vascular Ultrasound

    Get PDF

    Innovations in Vascular Ultrasound

    Get PDF

    A BCB Diaphragm Based Adhesive Wafer Bonded CMUT Probe for Biomedical Application

    Get PDF
    This dissertation presents the design methodology, fabrication procedure, and key experimental characterization results of a linear array of capacitive micromachined ultrasonic transducers (CMUT) for possible ophthalmic anterior segment imaging application. The design methodology involves analytical, 3-D electromechanical finite element analysis, and Verasonics Vantage 128 ultrasonic research platform based diagnostic imaging simulations to develop a technique that minimizes electrical charging and center frequency drift while improving the transduction efficiency. In the design, Bisbenzocyclobutene (BCB), a low K polymer from Dow Chemical Company, has been innovatively used for the first time to fabricate the structural layer of the CMUT diaphragm, realize the interelectrode dielectric spacer, and to act as a low temperature adhesive bonding agent. Additionally, the top CMUT electrode has been placed at the bottom of the diaphragm to affect higher capacitance change that increases sensitivity and provides additional decoupling of the electrical charging effects. Several arrays with element count ranging from 8 to 128 elements and a center frequency range of 5 MHz to 40 MHz have been designed and fabricated. Due to an unforeseen adhesion issue during wirebonding, a 32 channel 40 MHz CMUT array has been packaged manually to validate the fabrication process and CMUT operation. Extensive SEM inspections of the CMUT cross-sections show good agreement with the design specifications. Static and dynamic measurements using a Polytec laser Doppler vibrometer, impedance measurement using an Agilent vector network analyzer, and LCR measurement results are in excellent agreement with analytical and FEA analysis using IntelliSuite. The frequency analysis exhibits high electromechanical coupling coefficient of 0.66 at a low bias voltage of 20 V and high uniformity. A successful measurement of the lower drift of the center frequency 0.32% and higher coupling coefficient verifies the hypothesis that the excellent electrical, structural, and processing characteristics of BCB is a viable option to mitigate the dielectric charging and improve the transduction efficiency of CMUTs

    Development of a Focused Broadband Ultrasonic Transducer for High Resolution Fundamental and Harmonic Intravascular Imaging

    Get PDF
    Intravascular ultrasound (IVUS) is increasingly employed for detection and evaluation of coronary artery diseases. Tissue Harmonic Imaging provides different tissue information that could additionally be used to improve diagnostic accuracy. However, current IVUS systems, with their unfocussed transducers, may not be capable of operating in harmonic imaging mode. Thus, there is a need to develop suitable transducers and appropriate techniques to allow imaging in multi modes for complementary diagnostic information. Focused PVDF TrFE transducers were developed using MEMS (Micro-Electro-Mechanical-Systems) compatible protocols. The transducers were characterized using pulse-echo techniques and exhibited broad bandwidth (110 at -6dB) with axial resolutions of Such promising results suggest that focused, broadband PVDF TrFE transducers have opened up the potential to incorporate harmonic imaging modality in IVUS and also improve the image quality. In addition, the transducer\u27s multimodality imaging capability, not possible with the current systems, could enhance the functionality and thereby the clinical use of IVU

    Development of a Focused Broadband Ultrasonic Transducer for High Resolution Fundamental and Harmonic Intravascular Imaging

    Get PDF
    Intravascular ultrasound (IVUS) is increasingly employed for detection and evaluation of coronary artery diseases. Tissue Harmonic Imaging provides different tissue information that could additionally be used to improve diagnostic accuracy. However, current IVUS systems, with their unfocussed transducers, may not be capable of operating in harmonic imaging mode. Thus, there is a need to develop suitable transducers and appropriate techniques to allow imaging in multi modes for complementary diagnostic information. Focused PVDF TrFE transducers were developed using MEMS (Micro-Electro-Mechanical-Systems) compatible protocols. The transducers were characterized using pulse-echo techniques and exhibited broad bandwidth (110 at -6dB) with axial resolutions of Such promising results suggest that focused, broadband PVDF TrFE transducers have opened up the potential to incorporate harmonic imaging modality in IVUS and also improve the image quality. In addition, the transducer\u27s multimodality imaging capability, not possible with the current systems, could enhance the functionality and thereby the clinical use of IVU

    Development of a Focused Broadband Ultrasonic Transducer for High Resolution Fundamental and Harmonic Intravascular Imaging

    Get PDF
    Intravascular ultrasound (IVUS) is increasingly employed for detection and evaluation of coronary artery diseases. Tissue Harmonic Imaging provides different tissue information that could additionally be used to improve diagnostic accuracy. However, current IVUS systems, with their unfocussed transducers, may not be capable of operating in harmonic imaging mode. Thus, there is a need to develop suitable transducers and appropriate techniques to allow imaging in multi modes for complementary diagnostic information. Focused PVDF TrFE transducers were developed using MEMS (Micro-Electro-Mechanical-Systems) compatible protocols. The transducers were characterized using pulse-echo techniques and exhibited broad bandwidth (110 at -6dB) with axial resolutions of Such promising results suggest that focused, broadband PVDF TrFE transducers have opened up the potential to incorporate harmonic imaging modality in IVUS and also improve the image quality. In addition, the transducer\u27s multimodality imaging capability, not possible with the current systems, could enhance the functionality and thereby the clinical use of IVU

    Contents

    Get PDF
    corecore