499 research outputs found

    Three-Phase PLLs:A Review of Recent Advances

    Get PDF

    Quasi Type-1 PLL With Tunable Phase Detector for Unbalanced and Distorted Three-Phase Grid

    Get PDF
    International audienc

    Three-phase phase-locked loop synchronization algorithms for grid-connected renewable energy systems:A review

    Get PDF
    The increasing penetration of distributed renewable energy sources (RES) requires appropriate control techniques in order to remain interconnected and contribute in a proper way to the overall grid stability, whenever disturbances occur. In addition, the disconnection of RES due to synchronization problems must be avoided as this may result in penalties and loss of energy generation to RES operators. The control of RES mainly depends on the synchronization algorithm, which should be fast and accurately detect the grid voltage status (e.g., phase, amplitude, and frequency). Typically, phase-locked loop (PLL) synchronization techniques are used for the grid voltage monitoring. The design and performance of PLL directly affect the dynamics of the RES grid side converter (GSC). This paper presents the characteristics, design guidelines and features of advanced state-of-the-art PLL-based synchronization algorithms under normal, abnormal and harmonically-distorted grid conditions. Experimental tests on the selected PLL methods under different grid conditions are presented, followed by a comparative benchmarking and selection guide. Finally, corresponding PLL tuning procedures are discussed.This work was supported by the supported by the Research Promotion Foundation (RPF) of Cyprus under Project KOINA/SOLAR-ERA.NET/1215/06

    Enhanced Quasi Type-1 PLL-Based Multi-Functional Control of Single-Phase Dynamic Voltage Restorer

    Get PDF
    This paper considers the reference signal generation problem for the multi-functional operation of single-phase dynamic voltage restorers. For this purpose, a single-phase quasi type-1 phase-locked loop (QT1-PLL) is proposed. The pre-loop filter part of this PLL is composed of a frequency-fixed delayed signal cancellation method and a two-stage all-pass filter. Thanks to the frequency-fixed nature, the pre-loop filter is easy to implement and can provide rejection of any measurement offset. Moreover, this PLL benefits from the excellent harmonic robustness property of the conventional QT1-PLL. Small-signal modeling and gain tuning procedures are detailed in this paper. In order to track the reference voltage signals generated by the proposed PLL, a super-twisting sliding mode controller is also presented, which helps to achieve fast dynamic responses. Laboratory-scale prototype-based experimental studies were conducted to validate the developed reference generator and the controller. Experimental results show that the proposed method is fast in detecting and compensating any grid voltage anomalies to maintain constant load voltage despite voltage sag, swell, and harmonic distortions

    Performance Evaluation of Type-3 PLLs Under Wide Variation in Input Voltage and Frequency

    Get PDF

    An Analysis of Modified Demodulation-Based Grid Voltage Parameter Estimator

    Get PDF

    A Quasi open-loop robust three-phase grid-synchronization technique for non-ideal grid

    Get PDF
    Abstract Development of advanced grid‐synchronization technique for unbalanced and distorted grid is considered in this paper. In this context, self‐tuning filter (STF) is considered to extract the fundamental component from the measured unbalanced and distorted voltages. Standard STF considers balanced grid voltages which is not always possible to ensure in the actual power grid. To mitigate this issue, an extended STF is proposed by analyzing the standard STF in the state‐space framework. To make the proposed ESTF grid‐following, a robust open‐loop frequency estimator is also applied. The closed‐loop system enjoys excellent filtering benefit from the extended STF side while taking advantage of the fast convergence speed property of the open‐loop frequency estimation technique. Numerical simulation and experimental results with double second‐order generalized integrator phase‐locked loop are provided to validate the theoretical developments

    Reliable Grid Condition Detection and Control of Single-Phase Distributed Power Generation Systems

    Get PDF

    Comparative Performance Evaluation of Orthogonal-Signal-Generators-Based Single-Phase PLL Algorithms:A Survey

    Get PDF
    • 

    corecore