57 research outputs found

    Channel estimation and transmit power control in wireless body area networks

    Get PDF
    Wireless body area networks have recently received much attention because of their application to assisted living and remote patient monitoring. For these applications, energy minimisation is a critical issue since, in many cases, batteries cannot be easily replaced or recharged. Reducing energy expenditure by avoiding unnecessary high transmission power and minimising frame retransmissions is therefore crucial. In this study, a transmit power control scheme suitable for IEEE 802.15.6 networks operating in beacon mode with superframe boundaries is proposed. The transmission power is modulated, frame-by-frame, according to a run-time estimation of the channel conditions. Power measurements using the beacon frames are made periodically, providing reverse channel gain and an opportunistic fade margin, set on the basis of prior power fluctuations, is added. This approach allows tracking of the highly variable on-body to on-body propagation channel without the need to transmit additional probe frames. An experimental study based on test cases demonstrates the effectiveness of the scheme and compares its performance with alternative solutions presented in the literature

    Study of MAC Protocols for Mobile Wireless Body Sensor Networks

    Get PDF
    Wireless Body Area Networks (WBAN) also referred to as a body sensor network (BSN), is a wireless network of wearable computing devices. It has emerged as a key technology to provide real-time health monitoring of a patient and diagnose many life threatening diseases. WBAN operates in close vicinity to, on, or inside a human body and supports a variety of medical and non-medical applications. The design of a medium access control is a challenge due to the characteristics of wireless channel and the need to fulfill both requirements of mobility support and energy efficiency.  This paper presents a comparative study of IEEE 802.15.6, IEEE 804.15.4 and T-MAC in order to analyze the performance of each standard in terms of delay, throughput and energy consumption. Keywords: Biomedical, IEEE 802.15.6; T-MAC, IEEE 802.15.4, mobility, low-power communication, wireless body sensor networks, implantable sensors, healthcare applications, biosensors

    Performance evaluation of IEEE 802.15.6 CSMA/CA-based CANet WBAN

    Get PDF
    International audienceIn the recent few years, Wireless Body Area networks (WBANs) showed what can be done remotely to greatly improve healthcare systems and facilitate the life to elderly. One of the recent ehealth projects is CANet which aims at embedding a WBAN into a cane to monitor elderly/patients. Our main goal in this paper is to evaluate the performances of the emerging standard IEEE 802.15.6 when applied on different sensors from CANet eHealth project. At this end, we defined a small scenario extracted from CANet, and we assigned IEEE 802.15.6 priorities to the selected cane sensors according to their inherent characteristics. We considered further the mandatory RAP period of IEEE 802.15.6 superframe under the beacon period with superframes mode since it supports both normal and urgent traffic. Our results showed that the contention access behavior of this considered model of simulation depends on several constraints (including the nature of the studied application and the traffic types and frequency). This would be necessarily taken into account to get the most advantage of all features offered by WBANs standard IEEE 802.15.6. Keywords—Medium Access Control (MAC), wireless body area networks (WBANs), E-health, CANet project, wireless sensor networks (WSN), IEEE 802.15.6

    TraPy-MAC: Traffic Priority Aware Medium Access Control Protocol for Wireless Body Area Network

    Get PDF
    Recently, Wireless Body Area Network (WBAN) has witnessed significant attentions in research and product development due to the growing number of sensor-based applications in healthcare domain. Design of efficient and effective Medium Access Control (MAC) protocol is one of the fundamental research themes in WBAN. Static on-demand slot allocation to patient data is the main approach adopted in the design of MAC protocol in literature, without considering the type of patient data specifically the level of severity on patient data. This leads to the degradation of the performance of MAC protocols considering effectiveness and traffic adjustability in realistic medical environments. In this context, this paper proposes a Traffic Priority-Aware MAC (TraPy-MAC) protocol for WBAN. It classifies patient data into emergency and non-emergency categories based on the severity of patient data. The threshold value aided classification considers a number of parameters including type of sensor, body placement location, and data transmission time for allocating dedicated slots patient data. Emergency data are not required to carry out contention and slots are allocated by giving the due importance to threshold value of vital sign data. The contention for slots is made efficient in case of non-emergency data considering threshold value in slot allocation. Moreover, the slot allocation to emergency and non-emergency data are performed parallel resulting in performance gain in channel assignment. Two algorithms namely, Detection of Severity on Vital Sign data (DSVS), and ETS Slots allocation based on the Severity on Vital Sign (ETS-SVS) are developed for calculating threshold value and resolving the conflicts of channel assignment, respectively. Simulations are performed in ns2 and results are compared with the state-of-the-art MAC techniques. Analysis of results attests the benefit of TraPy-MAC in comparison with the state-of-the-art MAC in channel assignment in realistic medical environments

    A Proposal for Network Coding with the IEEE 802.15.6 Standard

    Get PDF
    We examine the Medium Access Control sublayer of the IEEE 802.15.6 Wireless Body Area Network (WBAN) standard, and propose minor modifications to the standard so that linear random network coding can be included to help improve energy efficiency and throughput of WBANs compatible with the standard. Both generation-based and sliding window approaches are possible, and a group-block acknowledgment scheme can be implemented by modifying block acknowledgment control type frames. Discussions on potential energy and throughput advantages of network coding are provided.Semiconductor Research Corporation. Interconnect Focus Center (Subcontract RA306-S1

    A token-based dynamic scheduled MAC protocol for health monitoring

    Get PDF
    Developments of wireless body area networks (WBANs) facilitate the pervasive health monitoring with mHealth applications. WBANs can support continuous health monitoring for the human body in convenience and high efficiency without any intervention. The monitoring data in health care have the characteristics of various data flows and heterogeneous data arrival rates, the transmission of which must be in timeliness and reliability, especially the burst data. Moreover, the energy-constraint nodes should be provident in energy consumption. Designing MAC protocols with high reliability and energy efficiency for WBANs is the prime consideration. In this paper, we propose a token-based two-round reservation MAC (TTR MAC) protocol based on IEEE 802.15.6 with considering the data features of health monitoring. With analyzing the characteristics of monitoring data, one-round reservation is conducted for periodic data and two-round reservation is generated adaptively for burst data to save energy. Besides, TTR MAC protocol assigns appropriate number of allocation slots to nodes in heterogeneous data arrival rates. Furthermore, a token is introduced on the basis of user priority and health severity index to indicate the transmission order of nodes with burst data, which highly decreases the average delay. In addition, a bit sequence scheduled algorithm is proposed for m-periodic (m>1) monitoring data for network capacity expansion. The simulation results show that TTR MAC protocol achieves higher energy efficiency and longer lifetime compared with IEEE 802.15.6 and other one-round reservation MAC (OR MAC) protocols for both 1-periodic and m-periodic data.info:eu-repo/semantics/publishedVersio

    Performance evaluation of wake-up radio based wireless body area network

    Get PDF
    Abstract. The last decade has been really ambitious in new research and development techniques to reduce energy consumption especially in wireless sensor networks (WSNs). Sensor nodes are usually battery-powered and thus have very limited lifetime. Energy efficiency has been the most important aspect to discuss when talking about wireless body area network (WBAN) in particular, since it is the bottleneck of these networks. Medium access control (MAC) protocols hold the vital position to determine the energy efficiency of a WBAN, which is a key design issue for battery operated sensor nodes. The wake-up radio (WUR) based MAC and physical layer (PHY) have been evaluated in this research work in order to contribute to the energy efficient solutions development. WUR is an on-demand approach in which the node is woken up by the wake-up signal (WUS). A WUS switches a node from sleep mode to wake up mode to start signal transmission and reception. The WUS is transmitted or received by a secondary radio transceiver, which operates on very low power. The energy benefit of using WUR is compared with conventional duty-cycling approach. As the protocol defines the nodes in WUR based network do not waste energy on idle listening and are only awakened when there is a request for communication, therefore, energy consumption is extremely low. The performance of WUR based MAC protocol has been evaluated for both physical layer (PHY) and MAC for transmission of WUS and data. The probabilities of miss detection, false alarm and detection error rates are calculated for PHY and the probabilities of collision and successful data transmission for channel access method Aloha is evaluated. The results are obtained to compute and compare the total energy consumption of WUR based network with duty cycling. The results prove that the WUR based networks have significant potential to improve energy efficiency, in comparison to conventional duty cycling approach especially, in the case of low data-reporting rate applications. The duty cycle approach is better than WUR approach when sufficiently low duty cycle is combined with highly frequent communication between the network nodes

    Resource Allocation in Wireless Body Area Networks: A Smart City Perspective

    Get PDF
    Healthcare is an essential service in smart cities. To deploy healthcare systems in such cities, personal health monitoring systems, infrastructure for collecting and delivering individual data, and a system for diagnosing symptoms are required. For the first requirement, wireless body area networks (WBANs) have recently received considerable attention from research communities. Owing to their main distinguishable features from general wireless sensor networks, research challenges regarding WBANs have been focused on network topology around the body and implanted nodes, efficient resource allocation, and power control. In this chapter, we provide a comprehensive discussion on the emerging research trends in the area of wireless sensor networks and a discussion of WBANs in terms of their resource allocation

    Impact of Parameter Adjustments in IEEE 802.15.6 MAC Protocol for Wireless Body Area Networks

    Get PDF
    The WBAN requires a MAC protocol that complies with the specific requirements and specifications of the body area network communication. Typically, this technology is implemented using the IEEE 802.15.6 standard, which employs the CSMA/CA mechanism. The WBAN confronts the challenge of managing the probability of heavy traffic due to the substantial medical data generated by numerous biomedical sensors. This scenario could lead to network congestion, increasing delay and packet losses, thereby posing a risk of network instability. Hence, selecting appropriate parameters is crucial for developing a MAC protocol to reduce delay and packet losses while enhancing the network throughput. This paper evaluates the performance of the IEEE 802.15.6 MAC protocol by modifying parameters such as packet rate, simulation duration, and the number of sender nodes. The IEEE 802.15.6 MAC protocol implementations are assessed regarding delay, throughput, and packet loss using the Castalia-3.3 framework based on the OMNeT++ 4.6 platform. The outcome of this study indicates that the MAC protocol for WBAN applications can be optimized by configuring the parameters correctly
    • …
    corecore