54 research outputs found

    Integrated optical fiber force myography sensor as pervasive predictor of hand postures

    Get PDF
    Force myography (FMG) is an appealing alternative to traditional electromyography in biomedical applications, mainly due to its simpler signal pattern and immunity to electrical interference. Most FMG sensors, however, send data to a computer for further processing, which reduces the user mobility and, thus, the chances for practical application. In this sense, this work proposes to remodel a typical optical fiber FMG sensor with smaller portable components. Moreover, all data acquisition and processing routines were migrated to a Raspberry Pi 3 Model B microprocessor, ensuring the comfort of use and portability. The sensor was successfully demonstrated for 2 input channels and 9 postures classification with an average precision and accuracy of ~99.5% and ~99.8%, respectively, using a feedforward artificial neural network of 2 hidden layers and a competitive output layer11CONSELHO NACIONAL DE DESENVOLVIMENTO CIENTÍFICO E TECNOLÓGICO - CNPQCOORDENAÇÃO DE APERFEIÇOAMENTO DE PESSOAL DE NÍVEL SUPERIOR - CAPESFUNDAÇÃO DE AMPARO À PESQUISA DO ESTADO DE SÃO PAULO - FAPESPNão tem0012017/25666-

    Sistema de miografia óptica para reconhecimento de gestos e posturas de mão

    Get PDF
    Orientador: Éric FujiwaraDissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia MecânicaResumo: Nesse projeto, demonstrou-se um sistema de miografia óptica como uma alternativa promissora para monitorar as posturas da mão e os gestos do usuário. Essa técnica se fundamenta em acompanhar as atividades musculares responsáveis pelos movimentos da mão com uma câmera externa, relacionando a distorção visual verificada no antebraço com a contração e o relaxamento necessários para dada postura. Três configurações de sensores foram propostas, estudadas e avaliadas. A primeira propôs monitorar a atividade muscular analisando a variação da frequência espacial de uma textura de listras uniformes impressa sobre a pele, enquanto que a segunda se caracteriza pela contagem de pixels de pele visível dentro da região de interesse. Ambas as configurações se mostraram inviáveis pela baixa robustez e alta demanda por condições experimentais controladas. Por fim, a terceira recupera o estado da mão acompanhando o deslocamento de uma série de marcadores coloridos distribuídos ao longo do antebraço. Com um webcam de 24 fps e 640 × 480 pixels, essa última configuração foi validada para oito posturas distintas, explorando principalmente a flexão e extensão dos dedos e do polegar, além da adução e abdução do último. Os dados experimentais, adquiridos off-line, são submetidos a uma rotina de processamento de imagens para extrair a informação espacial e de cor dos marcadores em cada quadro, dados esses utilizados para rastrear os mesmos marcadores ao longo de todos os quadros. Para reduzir a influência das vibrações naturais e inerentes ao corpo humano, um sistema de referencial local é ainda adotado dentro da própria região de interesse. Finalmente, os dados quadro a quadro com o ground truth são alimentados a uma rede neural artificial sequencial, responsável pela calibração supervisionada do sensor e posterior classificação das posturas. O desempenho do sistema para a classificação das oito posturas foi avaliado com base na validação cruzada com 10-folds, com a câmera monitorando o antebraço pela superfície interna ou externa. O sensor apresentou uma precisão de ?92.4% e exatidão de ?97.9% para o primeiro caso, e uma precisão de ?75.1% e exatidão de ?92.5% para o segundo, sendo comparável a outras técnicas de miografia, demonstrando a viabilidade do projeto e abrindo perspectivas para aplicações em interfaces humano-robôAbstract: In this work, an optical myography system is demonstrated as a promising alternative to monitor hand posture and gestures of the user. This technique is based on accompanying muscular activities responsible for hand motion with an external camera, and relating the visual deformation observed on the forearm to the muscular contractions/relaxations for a given posture. Three sensor designs were proposed, studied and evaluated. The first one intended to monitor muscular activity by analyzing the spatial frequency variation of a uniformly distributed stripe pattern stamped on the skin, whereas the second one is characterized by reckoning visible skin pixels inside the region of interest. Both designs are impracticable due to their low robustness and high demand for controlled experimental conditions. At last, the third design retrieves hand configuration by tracking visually the displacements of a series of color markers distributed over the forearm. With a webcam of 24 fps and 640 × 480 pixels, this design was validated for eight different postures, exploring fingers and thumb flexion/extension, plus thumb adduction/abduction. The experimental data are acquired offline and, then, submitted to an image processing routine to extract color and spatial information of the markers in each frame; the extracted data is subsequently used to track the same markers along all frames. To reduce the influence of human body natural and inherent vibrations, a local reference frame is yet adopted in the region of interest. Finally, the frame by frame data, along with the ground truth posture, are fed into a sequential artificial neural network, responsible for sensor supervised calibration and subsequent posture classification. The system performance was evaluated in terms of eight postures classification via 10-fold cross-validation, with the camera monitoring either the underside or the back of the forearm. The sensor presented a ?92.4% precision and ?97.9% accuracy for the former, and a ?75.1% precision and ?92.5% accuracy for the latter, being thus comparable to other myographic techniques; it also demonstrated that the project is feasible and offers prospects for human-robot interaction applicationsMestradoEngenharia MecanicaMestre em Engenharia Mecânica33003017CAPE

    Biosignal‐based human–machine interfaces for assistance and rehabilitation : a survey

    Get PDF
    As a definition, Human–Machine Interface (HMI) enables a person to interact with a device. Starting from elementary equipment, the recent development of novel techniques and unobtrusive devices for biosignals monitoring paved the way for a new class of HMIs, which take such biosignals as inputs to control various applications. The current survey aims to review the large literature of the last two decades regarding biosignal‐based HMIs for assistance and rehabilitation to outline state‐of‐the‐art and identify emerging technologies and potential future research trends. PubMed and other databases were surveyed by using specific keywords. The found studies were further screened in three levels (title, abstract, full‐text), and eventually, 144 journal papers and 37 conference papers were included. Four macrocategories were considered to classify the different biosignals used for HMI control: biopotential, muscle mechanical motion, body motion, and their combinations (hybrid systems). The HMIs were also classified according to their target application by considering six categories: prosthetic control, robotic control, virtual reality control, gesture recognition, communication, and smart environment control. An ever‐growing number of publications has been observed over the last years. Most of the studies (about 67%) pertain to the assistive field, while 20% relate to rehabilitation and 13% to assistance and rehabilitation. A moderate increase can be observed in studies focusing on robotic control, prosthetic control, and gesture recognition in the last decade. In contrast, studies on the other targets experienced only a small increase. Biopotentials are no longer the leading control signals, and the use of muscle mechanical motion signals has experienced a considerable rise, especially in prosthetic control. Hybrid technologies are promising, as they could lead to higher performances. However, they also increase HMIs’ complex-ity, so their usefulness should be carefully evaluated for the specific application

    Design of a low-cost sensor matrix for use in human-machine interactions on the basis of myographic information

    Get PDF
    Myographic sensor matrices in the field of human-machine interfaces are often poorly developed and not pushing the limits in terms of a high spatial resolution. Many studies use sensor matrices as a tool to access myographic data for intention prediction algorithms regardless of the human anatomy and used sensor principles. The necessity for more sophisticated sensor matrices in the field of myographic human-machine interfaces is essential, and the community already called out for new sensor solutions. This work follows the neuromechanics of the human and designs customized sensor principles to acquire the occurring phenomena. Three low-cost sensor modalities Electromyography, Mechanomyography, and Force Myography) were developed in a miniaturized size and tested in a pre-evaluation study. All three sensors comprise the characteristic myographic information of its modality. Based on the pre-evaluated sensors, a sensor matrix with 32 exchangeable and high-density sensor modules was designed. The sensor matrix can be applied around the human limbs and takes the human anatomy into account. A data transmission protocol was customized for interfacing the sensor matrix to the periphery with reduced wiring. The designed sensor matrix offers high-density and multimodal myographic information for the field of human-machine interfaces. Especially the fields of prosthetics and telepresence can benefit from the higher spatial resolution of the sensor matrix

    Smart Sensors for Healthcare and Medical Applications

    Get PDF
    This book focuses on new sensing technologies, measurement techniques, and their applications in medicine and healthcare. Specifically, the book briefly describes the potential of smart sensors in the aforementioned applications, collecting 24 articles selected and published in the Special Issue “Smart Sensors for Healthcare and Medical Applications”. We proposed this topic, being aware of the pivotal role that smart sensors can play in the improvement of healthcare services in both acute and chronic conditions as well as in prevention for a healthy life and active aging. The articles selected in this book cover a variety of topics related to the design, validation, and application of smart sensors to healthcare

    Novel Bidirectional Body - Machine Interface to Control Upper Limb Prosthesis

    Get PDF
    Objective. The journey of a bionic prosthetic user is characterized by the opportunities and limitations involved in adopting a device (the prosthesis) that should enable activities of daily living (ADL). Within this context, experiencing a bionic hand as a functional (and, possibly, embodied) limb constitutes the premise for mitigating the risk of its abandonment through the continuous use of the device. To achieve such a result, different aspects must be considered for making the artificial limb an effective support for carrying out ADLs. Among them, intuitive and robust control is fundamental to improving amputees’ quality of life using upper limb prostheses. Still, as artificial proprioception is essential to perceive the prosthesis movement without constant visual attention, a good control framework may not be enough to restore practical functionality to the limb. To overcome this, bidirectional communication between the user and the prosthesis has been recently introduced and is a requirement of utmost importance in developing prosthetic hands. Indeed, closing the control loop between the user and a prosthesis by providing artificial sensory feedback is a fundamental step towards the complete restoration of the lost sensory-motor functions. Within my PhD work, I proposed the development of a more controllable and sensitive human-like hand prosthesis, i.e., the Hannes prosthetic hand, to improve its usability and effectiveness. Approach. To achieve the objectives of this thesis work, I developed a modular and scalable software and firmware architecture to control the Hannes prosthetic multi-Degree of Freedom (DoF) system and to fit all users’ needs (hand aperture, wrist rotation, and wrist flexion in different combinations). On top of this, I developed several Pattern Recognition (PR) algorithms to translate electromyographic (EMG) activity into complex movements. However, stability and repeatability were still unmet requirements in multi-DoF upper limb systems; hence, I started by investigating different strategies to produce a more robust control. To do this, EMG signals were collected from trans-radial amputees using an array of up to six sensors placed over the skin. Secondly, I developed a vibrotactile system to implement haptic feedback to restore proprioception and create a bidirectional connection between the user and the prosthesis. Similarly, I implemented an object stiffness detection to restore tactile sensation able to connect the user with the external word. This closed-loop control between EMG and vibration feedback is essential to implementing a Bidirectional Body - Machine Interface to impact amputees’ daily life strongly. For each of these three activities: (i) implementation of robust pattern recognition control algorithms, (ii) restoration of proprioception, and (iii) restoration of the feeling of the grasped object's stiffness, I performed a study where data from healthy subjects and amputees was collected, in order to demonstrate the efficacy and usability of my implementations. In each study, I evaluated both the algorithms and the subjects’ ability to use the prosthesis by means of the F1Score parameter (offline) and the Target Achievement Control test-TAC (online). With this test, I analyzed the error rate, path efficiency, and time efficiency in completing different tasks. Main results. Among the several tested methods for Pattern Recognition, the Non-Linear Logistic Regression (NLR) resulted to be the best algorithm in terms of F1Score (99%, robustness), whereas the minimum number of electrodes needed for its functioning was determined to be 4 in the conducted offline analyses. Further, I demonstrated that its low computational burden allowed its implementation and integration on a microcontroller running at a sampling frequency of 300Hz (efficiency). Finally, the online implementation allowed the subject to simultaneously control the Hannes prosthesis DoFs, in a bioinspired and human-like way. In addition, I performed further tests with the same NLR-based control by endowing it with closed-loop proprioceptive feedback. In this scenario, the results achieved during the TAC test obtained an error rate of 15% and a path efficiency of 60% in experiments where no sources of information were available (no visual and no audio feedback). Such results demonstrated an improvement in the controllability of the system with an impact on user experience. Significance. The obtained results confirmed the hypothesis of improving robustness and efficiency of a prosthetic control thanks to of the implemented closed-loop approach. The bidirectional communication between the user and the prosthesis is capable to restore the loss of sensory functionality, with promising implications on direct translation in the clinical practice
    corecore