14 research outputs found

    Nonrigid Registration Using Regularization that Accomodates Local Tissue Rigidity

    Full text link
    Regularized nonrigid medical image registration algorithms usually estimate the deformation by minimizing a cost function, consisting of a similarity measure and a penalty term that discourages “unreasonable” deformations. Conventional regularization methods enforce homogeneous smoothness properties of the deformation field; less work has been done to incorporate tissue-type-specific elasticity information. Yet ignoring the elasticity differences between tissue types can result in non-physical results, such as bone warping. Bone structures should move rigidly (locally), unlike the more elastic deformation of soft issues. Existing solutions for this problem either treat different regions of an image independently, which requires precise segmentation and incurs boundary issues; or use an empirical spatial varying “filter” to “correct” the deformation field, which requires the knowledge of a stiffness map and departs from the cost-function formulation. We propose a new approach to incorporate tissue rigidity information into the nonrigid registration problem, by developing a space variant regularization function that encourages the local Jacobian of the deformation to be a nearly orthogonal matrix in rigid image regions, while allowing more elastic deformations elsewhere. For the case of X-ray CT data, we use a simple monotonic increasing function of the CT numbers (in HU) as a “rigidity index” since bones typically have the highest CT numbers. Unlike segmentation-based methods, this approach is flexible enough to account for partial volume effects. Results using a B-spline deformation parameterization illustrate that the proposed approach improves registration accuracy in inhale-exhale CT scans with minimal computational penalty.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85935/1/Fessler216.pd

    A Simple Penalty that Encourages Local Invertibility and Considers Sliding Effects for Respiratory Motion

    Full text link
    Nonrigid image registration is a key tool in medical imaging. Because of high degrees of freedom in nonrigid transforms, there have been many efforts to regularize the deformation based on some reasonable assumptions. Especially, motion invertibility and local tissue rigidity have been investigated as reasonable priors in image registration. There have been several papers on exploiting each constraint separately. These constraints are reasonable in respiratory motion estimation because breathing motion is invertible and there are some rigid structures such as bones. Using both constraints seems very attractive in respiratory motion registration since using invertibility prior alone usually causes bone warping in ribs. Using rigidity prior seems natural and straightforward. However, the “sliding effect” near the interface between rib cage and diaphragm makes problem harder because it is not locally invertible. In this area, invertibility and rigidity priors have opposite forces. Recently, we proposed a simple piecewise quadratic penalty that encourages the local invertibility of motions. In this work we relax this penalty function by using a Geman-type function that allows the deformation to be piecewise smooth instead of globally smooth. This allows the deformation to be discontinuous in the area of the interface between rib cage and diaphragm. With some small sacrifice of regularity, we could achieve more realistic discontinuous motion near diaphragm, better data fitting error as well as less bone warping. We applied this Geman-type function penalty only to the x- and y-direction partial derivatives of the z-direction deformation to address the sliding effect. 192 × 128 × 128 3D CT inhale and exhale images of a real patient were used to show the benefits of this new penalty method.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85922/1/Fessler238.pd

    Regularized Methods for Topology-Preserving Smooth Nonrigid Image Registration Using B-Spline Basis

    Full text link
    B-splines are a convenient tool for nonrigid registration, but ensuring invertibility can be challenge. This paper describes a new penalty method that is devised to enforce a sufficient condition for local invertibility and smoothness of nth order B-spline based deformations. Traditional direct Jacobian penalty methods penalize negative Jacobian determinant values only at grid points. In contrast, our new penalty method enforces the sufficient condition for invertibility directly on the B-spline coefficients by using a modified quadratic penalty function so that it enforces invertibility globally over a 3D continuous domain. This approach also saves computation time and memory compared to using Jacobian determinant values. We apply this method to 3D CT images of a thorax at inhale and exhale.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85874/1/Fessler232.pd

    A Simple Regularizer for B-spline Nonrigid Image Registration That Encourages Local Invertibility

    Full text link
    Nonrigid image registration is an important task for many medical imaging applications. In particular, for radiation oncology it is desirable to track respiratory motion for thoracic cancer treatment. B-splines are convenient for modeling nonrigid deformations, but ensuring invertibility can be a challenge. This paper describes sufficient conditions for local invertibility of deformations based on B-spline bases. These sufficient conditions can be used with constrained optimization to enforce local invertibility. We also incorporate these conditions into nonrigid image registration methods based on a simple penalty approach that encourages diffeomorphic deformations. Traditional Jacobian penalty methods penalize negative Jacobian determinant values only at grid points. In contrast, our new method enforces a sufficient condition for invertibility directly on the deformation coefficients to encourage invertibility globally over a 3-D continuous domain. The proposed penalty approach requires substantially less compute time than Jacobian penalties per iteration.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/85951/1/Fessler21.pd

    Automated diffeomorphic registration of anatomical structures with rigid parts: application to dynamic cervical MRI.

    No full text
    International audienceWe propose an iterative two-step method to compute a diffeomorphic non-rigid transformation between images of anatomical structures with rigid parts, without any user intervention or prior knowledge on the image intensities. First we compute spatially sparse, locally optimal rigid transformations between the two images using a new block matching strategy and an efficient numerical optimiser (BOBYQA). Then we derive a dense, regularised velocity field based on these local transformations using matrix logarithms and M-smoothing. These two steps are iterated until convergence and the final diffeomorphic transformation is defined as the exponential of the accumulated velocity field. We show our algorithm to outperform the state-of-the-art log-domain diffeomorphic demons method on dynamic cervical MRI data

    DEFORM'06 - Proceedings of the Workshop on Image Registration in Deformable Environments

    Get PDF
    Preface These are the proceedings of DEFORM'06, the Workshop on Image Registration in Deformable Environments, associated to BMVC'06, the 17th British Machine Vision Conference, held in Edinburgh, UK, in September 2006. The goal of DEFORM'06 was to bring together people from different domains having interests in deformable image registration. In response to our Call for Papers, we received 17 submissions and selected 8 for oral presentation at the workshop. In addition to the regular papers, Andrew Fitzgibbon from Microsoft Research Cambridge gave an invited talk at the workshop. The conference website including online proceedings remains open, see http://comsee.univ-bpclermont.fr/events/DEFORM06. We would like to thank the BMVC'06 co-chairs, Mike Chantler, Manuel Trucco and especially Bob Fisher for is great help in the local arrangements, Andrew Fitzgibbon, and the Programme Committee members who provided insightful reviews of the submitted papers. Special thanks go to Marc Richetin, head of the CNRS Research Federation TIMS, which sponsored the workshop. August 2006 Adrien Bartoli Nassir Navab Vincent Lepeti

    A Symmetric Prior for the Regularisation of Elastic Deformations: Improved anatomical plausibility in nonlinear image registration

    Get PDF
    Nonlinear registration is critical to many aspects of Neuroimaging research. It facilitates averaging and comparisons across multiple subjects, as well as reporting of data in a common anatomical frame of reference. It is, however, a fundamentally ill-posed problem, with many possible solutions which minimise a given dissimilarity metric equally well. We present a regularisation method capable of selectively driving solutions towards those which would be considered anatomically plausible by penalising unlikely lineal, areal and volumetric deformations. This penalty is symmetric in the sense that geometric expansions and contractions are penalised equally, which encourages inverse-consistency. We demonstrate that this method is able to significantly reduce local volume changes and shape distortions compared to state-of-the-art elastic (FNIRT) and plastic (ANTs) registration frameworks. Crucially, this is achieved whilst simultaneously matching or exceeding the registration quality of these methods, as measured by overlap scores of labelled cortical regions. Extensive leveraging of GPU parallelisation has allowed us to solve this highly computationally intensive optimisation problem while maintaining reasonable run times of under half an hour

    Automated Image-Based Procedures for Adaptive Radiotherapy

    Get PDF

    Anatomically-adaptive multi-modal image registration for image-guided external-beam radiotherapy

    Get PDF
    Image-guided radiotherapy (IGRT) allows observation of the location and shape of the tumor and organs-at-risk (OAR) over the course of a radiation cancer treatment. Such information may in turn be used for reducing geometric uncertainties during therapeutic planning, dose delivery and response assessment. However, given the multiple imaging modalities and/or contrasts potentially included within the imaging protocol over the course of the treatment, the current manual approach to determining tissue displacement may become time-consuming and error prone. In this context, variational multi-modal deformable image registration (DIR) algorithms allow automatic estimation of tumor and OAR deformations across the acquired images. In addition, they require short computational times and a low number of input parameters, which is particularly beneficial for online adaptive applications, which require on-the-fly adaptions with the patient on the treatment table. However, the majority of such DIR algorithms assume that all structures across the entire field-of-view (FOV) undergo a similar deformation pattern. Given that various anatomical structures may behave considerably different, this may lead to the estimation of anatomically implausible deformations at some locations, thus limiting their validity. Therefore, in this paper we propose an anatomically-adaptive variational multi-modal DIR algorithm, which employs a regionalized registration model in accordance with the local underlying anatomy. The algorithm was compared against two existing methods which employ global assumptions on the estimated deformations patterns. Compared to the existing approaches, the proposed method has demonstrated an improved anatomical plausibility of the estimated deformations over the entire FOV as well as displaying overall higher accuracy. Moreover, despite the more complex registration model, the proposed approach is very fast and thus suitable for online scenarios. Therefore, future adaptive IGRT workflows may benefit from an anatomically-adaptive registration model for precise contour propagation and dose accumulation, in areas showcasing considerable variations in anatomical properties

    Multimodal intra- and inter-subject nonrigid registration of small animal images.

    Get PDF
    corecore