651 research outputs found

    Spatial Smoothing for Diffusion Tensor Imaging with low Signal to Noise Ratios

    Get PDF
    Though low signal to noise ratio (SNR) experiments in DTI give key information about tracking and anisotropy, e.g. by measurements with very small voxel sizes, due to the complicated impact of thermal noise such experiments are up to now seldom analysed. In this paper Monte Carlo simulations are presented which investigate the random fields of noise for different DTI variables in low SNR situations. Based on this study a strategy for spatial smoothing, which demands essentially uniform noise, is derived. To construct a convenient filter the weights of the nonlinear Aurich chain are adapted to DTI. This edge preserving three dimensional filter is then validated in different variants via a quasi realistic model and is applied to very new data with isotropic voxels of the size 1x1x1 mm3 which correspond to a spatial mean SNR of approximately 3

    Axon diameters and myelin content modulate microscopic fractional anisotropy at short diffusion times in fixed rat spinal cord

    Full text link
    Mapping tissue microstructure accurately and noninvasively is one of the frontiers of biomedical imaging. Diffusion Magnetic Resonance Imaging (MRI) is at the forefront of such efforts, as it is capable of reporting on microscopic structures orders of magnitude smaller than the voxel size by probing restricted diffusion. Double Diffusion Encoding (DDE) and Double Oscillating Diffusion Encoding (DODE) in particular, are highly promising for their ability to report on microscopic fractional anisotropy ({\mu}FA), a measure of the pore anisotropy in its own eigenframe, irrespective of orientation distribution. However, the underlying correlates of {\mu}FA have insofar not been studied. Here, we extract {\mu}FA from DDE and DODE measurements at ultrahigh magnetic field of 16.4T in the aim to probe fixed rat spinal cord microstructure. We further endeavor to correlate {\mu}FA with Myelin Water Fraction (MWF) derived from multiexponential T2 relaxometry, as well as with literature-based spatially varying axonal diameters. In addition, a simple new method is presented for extracting unbiased {\mu}FA from three measurements at different b-values. Our findings reveal strong anticorrelations between {\mu}FA (derived from DODE) and axon diameter in the distinct spinal cord tracts; a moderate correlation was also observed between {\mu}FA derived from DODE and MWF. These findings suggest that axonal membranes strongly modulate {\mu}FA, which - owing to its robustness towards orientation dispersion effects - reflects axon diameter much better than its typical FA counterpart. The {\mu}FA exhibited modulations when measured via oscillating or blocked gradients, suggesting selective probing of different parallel path lengths and providing insight into how those modulate {\mu}FA metrics. Our findings thus shed light into the underlying microstructural correlates of {\mu}FA and are (...

    Spherical deconvolution of multichannel diffusion MRI data with non-Gaussian noise models and spatial regularization

    Get PDF
    Spherical deconvolution (SD) methods are widely used to estimate the intra-voxel white-matter fiber orientations from diffusion MRI data. However, while some of these methods assume a zero-mean Gaussian distribution for the underlying noise, its real distribution is known to be non-Gaussian and to depend on the methodology used to combine multichannel signals. Indeed, the two prevailing methods for multichannel signal combination lead to Rician and noncentral Chi noise distributions. Here we develop a Robust and Unbiased Model-BAsed Spherical Deconvolution (RUMBA-SD) technique, intended to deal with realistic MRI noise, based on a Richardson-Lucy (RL) algorithm adapted to Rician and noncentral Chi likelihood models. To quantify the benefits of using proper noise models, RUMBA-SD was compared with dRL-SD, a well-established method based on the RL algorithm for Gaussian noise. Another aim of the study was to quantify the impact of including a total variation (TV) spatial regularization term in the estimation framework. To do this, we developed TV spatially-regularized versions of both RUMBA-SD and dRL-SD algorithms. The evaluation was performed by comparing various quality metrics on 132 three-dimensional synthetic phantoms involving different inter-fiber angles and volume fractions, which were contaminated with noise mimicking patterns generated by data processing in multichannel scanners. The results demonstrate that the inclusion of proper likelihood models leads to an increased ability to resolve fiber crossings with smaller inter-fiber angles and to better detect non-dominant fibers. The inclusion of TV regularization dramatically improved the resolution power of both techniques. The above findings were also verified in brain data

    DTI denoising for data with low signal to noise ratios

    Get PDF
    Low signal to noise ratio (SNR) experiments in diffusion tensor imaging (DTI) give key information about tracking and anisotropy, e. g., by measurements with small voxel sizes or with high b values. However, due to the complicated and dominating impact of thermal noise such data are still seldom analysed. In this paper Monte Carlo simulations are presented which investigate the distributions of noise for different DTI variables in low SNR situations. Based on this study a strategy for the application of spatial smoothing is derived. Optimal prerequisites for spatial filters are unbiased, bell shaped distributions with uniform variance, but, only few variables have a statistics close to that. To construct a convenient filter a chain of nonlinear Gaussian filters is adapted to peculiarities of DTI and a bias correction is introduced. This edge preserving three dimensional filter is then validated via a quasi realistic model. Further, it is shown that for small sample sizes the filter is as effective as a maximum likelihood estimator and produces reliable results down to a local SNR of approximately 1. The filter is finally applied to very recent data with isotropic voxels of the size 1×1×1mm^3 which corresponds to a spatially mean SNR of 2.5. This application demonstrates the statistical robustness of the filter method. Though the Rician noise model is only approximately realized in the data, the gain of information by spatial smoothing is considerable

    Non-local means based Rician noise filtering for diffusion tensor and kurtosis imaging in human brain and spinal cord

    Get PDF
    Background: To investigate the effect of using a Rician nonlocal means (NLM) filter on quantification of diffusion tensor (DT)- and diffusion kurtosis (DK)-derived metrics in various anatomical regions of the human brain and the spinal cord, when combined with a constrained linear least squares (CLLS) approach. / Methods: Prospective brain data from 9 healthy subjects and retrospective spinal cord data from 5 healthy subjects from a 3 T MRI scanner were included in the study. Prior to tensor estimation, registered diffusion weighted images were denoised by an optimized blockwise NLM filter with CLLS. Mean kurtosis (MK), radial kurtosis (RK), axial kurtosis (AK), mean diffusivity (MD), radial diffusivity (RD), axial diffusivity (AD) and fractional anisotropy (FA), were determined in anatomical structures of the brain and the spinal cord. DTI and DKI metrics, signal-to-noise ratio (SNR) and Chi-square values were quantified in distinct anatomical regions for all subjects, with and without Rician denoising. / Results: The averaged SNR significantly increased with Rician denoising by a factor of 2 while the averaged Chi-square values significantly decreased up to 61% in the brain and up to 43% in the spinal cord after Rician NLM filtering. In the brain, the mean MK varied from 0.70 (putamen) to 1.27 (internal capsule) while AK and RK varied from 0.58 (corpus callosum) to 0.92 (cingulum) and from 0.70 (putamen) to 1.98 (corpus callosum), respectively. In the spinal cord, FA varied from 0.78 in lateral column to 0.81 in dorsal column while MD varied from 0.91 × 10−3 mm2/s (lateral) to 0.93 × 10−3 mm2/s (dorsal). RD varied from 0.34 × 10−3 mm2/s (dorsal) to 0.38 × 10−3 mm2/s (lateral) and AD varied from 1.96 × 10−3 mm2/s (lateral) to 2.11 × 10−3 mm2/s (dorsal). / Conclusions: Our results show a Rician denoising NLM filter incorporated with CLLS significantly increases SNR and reduces estimation errors of DT- and KT-derived metrics, providing the reliable metrics estimation with adequate SNR levels

    Improving Estimation of Fiber Orientations in Diffusion MRI Using Inter-Subject Information Sharing

    Get PDF
    Diffusion magnetic resonance imaging is widely used to investigate diffusion patterns of water molecules in the human brain. It provides information that is useful for tracing axonal bundles and inferring brain connectivity. Diffusion axonal tracing, namely tractography, relies on local directional information provided by the orientation distribution functions (ODFs) estimated at each voxel. To accurately estimate ODFs, data of good signal-to-noise ratio and sufficient angular samples are desired. This is however not always available in practice. In this paper, we propose to improve ODF estimation by using inter-subject image correlation. Specifically, we demonstrate that diffusion-weighted images acquired from different subjects can be transformed to the space of a target subject to drastically increase the number of angular samples to improve ODF estimation. This is largely due to the incoherence of the angular samples generated when the diffusion signals are reoriented and warped to the target space. To reorient the diffusion signals, we propose a new spatial normalization method that directly acts on diffusion signals using local affine transforms. Experiments on both synthetic data and real data show that our method can reduce noise-induced artifacts, such as spurious ODF peaks, and yield more coherent orientations
    corecore