505 research outputs found

    Negative exponential behavior of image mutual information for pseudo-thermal light ghost imaging: Observation, modeling, and verification

    Full text link
    When use the image mutual information to assess the quality of reconstructed image in pseudo-thermal light ghost imaging, a negative exponential behavior with respect to the measurement number is observed. Based on information theory and a few simple and verifiable assumptions, semi-quantitative model of image mutual information under varying measurement numbers is established. It is the Gaussian characteristics of the bucket detector output probability distribution that leads to this negative exponential behavior. Designed experiments verify the model.Comment: 13 pages, 6 figure

    Enhanced retinal image registration accuracy using expectation maximisation and variable bin-sized mutual information

    Get PDF
    While retinal images (RI) assist in the diagnosis of various eye conditions and diseases such as glaucoma and diabetic retinopathy, their innate features including low contrast homogeneous and nonuniformly illuminated regions, present a particular challenge for retinal image registration (RIR). Recently, the hybrid similarity measure, Expectation Maximization for Principal Component Analysis with Mutual Information (EMPCA-MI) has been proposed for RIR. This paper investigates incorporating various fixed and adaptive bin size selection strategies to estimate the probability distribution in the mutual information (MI) stage of EMPCA-MI, and analyses their corresponding effect upon RIR performance. Experimental results using a clinical mono-modal RI dataset confirms that adaptive bin size selection consistently provides both lower RIR errors and superior robustness compared to the empirically determined fixed bin sizes

    Multimodal retinal image registration using a fast principal component analysis hybrid-based similarity measure

    Get PDF
    Multimodal retinal images (RI) are extensively used for analysing various eye diseases and conditions such as myopia and diabetic retinopathy. The incorporation of either two or more RI modalities provides complementary structure information in the presence of non-uniform illumination and low-contrast homogeneous regions. It also presents significant challenges for retinal image registration (RIR). This paper investigates how the Expectation Maximization for Principal Component Analysis with Mutual Information (EMPCA-MI) algorithm can effectively achieve multimodal RIR. This iterative hybrid-based similarity measure combines spatial features with mutual information to provide enhanced registration without recourse to either segmentation or feature extraction. Experimental results for clinical multimodal RI datasets comprising colour fundus and scanning laser ophthalmoscope images confirm EMPCA-MI is able to consistently afford superior numerical and qualitative registration performance compared with existing RIR techniques, such as the bifurcation structures method

    Enhanced phase congruency feature-based image registration for multimodal remote sensing imagery

    Get PDF
    Multimodal image registration is an essential image processing task in remote sensing. Basically, multimodal image registration searches for optimal alignment between images captured by different sensors for the same scene to provide better visualization and more informative images. Manual image registration is a tedious task and requires more effort, hence developing an automated image registration is very crucial to provide a faster and reliable solution. However, image registration faces many challenges from the nature of remote sensing image, the environment, and the technical shortcoming of the current methods that cause three issues, namely intensive processing power, local intensity variation, and rotational distortion. Since not all image details are significant, relying on the salient features will be more efficient in terms of processing power. Thus, the feature-based registration method was adopted as an efficient method to avoid intensive processing. The proposed method resolves rotation distortion issue using Oriented FAST and Rotated BRIEF (ORB) to produce invariant rotation features. However, since it is not intensity invariant, it cannot support multimodal data. To overcome the intensity variations issue, Phase Congruence (PC) was integrated with ORB to introduce ORB-PC feature extraction to generate feature invariance to rotation distortion and local intensity variation. However, the solution is not complete since the ORB-PC matching rate is below the expectation. Enhanced ORB-PC was proposed to solve the matching issue by modifying the feature descriptor. While better feature matches were achieved, a high number of outliers from multimodal data makes the common outlier removal methods unsuccessful. Therefore, the Normalized Barycentric Coordinate System (NBCS) outlier removal was utilized to find precise matches even with a high number of outliers. The experiments were conducted to verify the registration qualitatively and quantitatively. The qualitative experiment shows the proposed method has a broader and better features distribution, while the quantitative evaluation indicates improved performance in terms of registration accuracy by 18% compared to the related works

    Improvements in the registration of multimodal medical imaging : application to intensity inhomogeneity and partial volume corrections

    Get PDF
    Alignment or registration of medical images has a relevant role on clinical diagnostic and treatment decisions as well as in research settings. With the advent of new technologies for multimodal imaging, robust registration of functional and anatomical information is still a challenge, particular in small-animal imaging given the lesser structural content of certain anatomical parts, such as the brain, than in humans. Besides, patient-dependent and acquisition artefacts affecting the images information content further complicate registration, as is the case of intensity inhomogeneities (IIH) showing in MRI and the partial volume effect (PVE) attached to PET imaging. Reference methods exist for accurate image registration but their performance is severely deteriorated in situations involving little images Overlap. While several approaches to IIH and PVE correction exist these methods still do not guarantee or rely on robust registration. This Thesis focuses on overcoming current limitations af registration to enable novel IIH and PVE correction methods.El registre d'imatges mèdiques té un paper rellevant en les decisions de diagnòstic i tractament clíniques així com en la recerca. Amb el desenvolupament de noves tecnologies d'imatge multimodal, el registre robust d'informació funcional i anatòmica és encara avui un repte, en particular, en imatge de petit animal amb un menor contingut estructural que en humans de certes parts anatòmiques com el cervell. A més, els artefactes induïts pel propi pacient i per la tècnica d'adquisició que afecten el contingut d'informació de les imatges complica encara més el procés de registre. És el cas de les inhomogeneïtats d'intensitat (IIH) que apareixen a les RM i de l'efecte de volum parcial (PVE) característic en PET. Tot i que existeixen mètodes de referència pel registre acurat d'imatges la seva eficàcia es veu greument minvada en casos de poc solapament entre les imatges. De la mateixa manera, també existeixen mètodes per la correcció d'IIH i de PVE però que no garanteixen o que requereixen un registre robust. Aquesta tesi es centra en superar aquestes limitacions sobre el registre per habilitar nous mètodes per la correcció d'IIH i de PVE

    Volume cardiac SPECT image registration

    Get PDF
    The registration of cardiac images is relevant for the diagnosis of cardiac pathologies. In the case of SPECT (Single Photon Emission Computer Tomography) datasets, this is difficult because of the low resolution of the images. In this paper we present a new registration method for 3D images with poor resolution. Our method is based on the maximization of the mutual information (MI) using a new interpolation method which significantly improves the result of an MI-based strategy on low resolution images. We also use a different optimization strategy than other MI-based algorithms, typically achieving errors of the order of one pixel. We also discuss experimental results of our method.Postprint (published version
    corecore