336 research outputs found

    Imposed Switching Frequency Direct Torque Control of Induction Machine Using Five Level Flying Capacitors Inverter

    Get PDF
    The paper proposes a new control structure for sensorless induction motor drive based on a five-level voltage source inverter (VSI). The output voltages of the five-level VSI can be represented by nine groups. Then, the amplitude and the rotating velocity of the flux vector can be controlled freely. Both fast torque and optimal switching logic can be obtained. The selection is based on the value of the stator flux and the torque. This paper investigates a new control structure focused on controlling switching frequency and torque harmonics contents. These strategies, called ISFDTC, indeed combines harmoniously both these factors, without compromising the excellence of the dynamical performances typically conferred to standard DTC strategies. The validity of the proposed control technique is verified by Matlab/Simulink. Simulation results presented in this paper confirm the validity and feasibility of the proposed control approach and can be tested on experimental setup.Peer reviewe

    Model Predictive Controlled Active NPC Inverter for Voltage Stress Balancing among the Semiconductor Power Switches

    Full text link
    © Published under licence by IOP Publishing Ltd. This paper presents a model predictive controlled three-level three-phase active neutral-point-clamped (ANPC) inverter for distributing the voltage stress among the semiconductor power switches as well as balancing the neutral-point voltage. The model predictive control (MPC) concept uses the discrete variables and effectively operates the ANPC inverter by avoiding any linear controller or modulation techniques. A 4.0 kW three-level three-phase ANPC inverter is developed in the MATLAB/Simulink environment to verify the effectiveness of the proposed MPC scheme. The results confirm that the proposed model predictive controlled ANPC inverter equally distributes the voltage across all the semiconductor power switches and provides lowest THD (0.99%) compared with the traditional NPC inverter. Moreover, the neutral-point voltage balancing is accurately maintained by the proposed MPC algorithm. Furthermore, this MPC concept shows the robustness capability against the parameter uncertainties of the system which is also analyzed by MATLAB/Simulink

    A Novel Control Approach to Hybrid Multilevel Inverter for High-Power Applications

    Get PDF
    This paper proposes a hybrid control scheme for a newly devised hybrid multilevel inverter (HMLI) topology. The circuit configuration of HMLI is comprised of a cascaded converter module (CCM), connected in series with an H-bridge converter. Initially, a finite set model predictive control (FS-MPC) is adopted as a control scheme, and theoretical analysis is carried out in MATLAB/Simulink. Later, in the real-time implementation of the HMLI topology, a hybrid control scheme which is a variant of the FS-MPC method has been proposed. The proposed control method is computationally efficient and therefore has been employed to the HMLI topology to mitigate the high-frequency switching limitation of the conventional MPC. Moreover, a comparative analysis is carried to illustrate the advantages of the proposed work that includes low switching losses, higher efficiency, and improved total harmonic distortion (THD) in output current. The inverter topology and stability of the proposed control method have been validated through simulation results in MATLAB/Simulink environment. Experimental results via low-voltage laboratory prototype have been added and compared to realize the study in practice.publishedVersio

    Analysis and Design of Methods for Condition Monitoring of Capacitors in Multilevel Converters

    Get PDF
    Multi-level converters are an important class of power electronics based systems that enable seamless conversion of electrical power from one form to another. Due to its distinct merits, it finds a vast scope of application in the fields such as renewable energy, electrical power transmission, adjustable speed drives, uninterrupted power supplies and custom power devices. These merits often come at a cost of increased complexity, higher number of power semiconductor devices and higher number of energy storage elements. Multi-level converters generates staircase waveform by use of high density capacitor banks. These capacitor banks are often subject to failure due to vaporization of electrolyte forming weakest link in reliability context. This thesis addresses reliability issue by proposing an online condition monitoring method for a three-level neutral point clamped multi-level converter which can be easily integrated with existing control methods. The proposed method provides an online estimate of existing capacitance in DC-link and helps increase in reliability in terms of preventive maintenance. The validity of proposed technique is obtained by verification of the method on a 3KVA laboratory developed experimental prototype. It also addresses reliability by developing tool in terms of analytical expressions which can be used as a ready reckoner for proper design of capacitor bank employed in five-level active neutral point clamped multi-level converter. Results from this developed tool are quantitatively verified with the results obtained from converter models developed over MATLAB Simulink environment confirming their accuracy

    Predictive direct torque control using a cascade asymmetric multilevel converter

    Get PDF
    A Direct Torque Control scheme which regulates the flux and the electromagnetictorque of an induction motor (IM) is presented in this paper. A Cascade Asymmetric Multilevel Converter (CAMC) drives the IM in 7-level mode using a new voltage value for the flying capacitors. An integrated control scheme based on the Finite-Control- Set Model Predictive Control (FCS-MPC) approach undertakes the solution as a unique multi-objective control problem. The algorithm directly selects theswitching states according to a rule of optimization and avoiding the use of modulators and nested controllers.Instituto de Investigaciones en Electrónica, Control y Procesamiento de SeñalesConsejo Nacional de Investigaciones Científicas y Técnica

    Four-Level Three-Phase Inverter With Reduced Component Count for Low and Medium Voltage Applications

    Get PDF
    publishedVersio

    Development of a multilevel converter topology for transformer-less connection of renewable energy systems

    Get PDF
    The global need to reduce dependence on fossil fuels for electricity production has become an ongoing research theme in the last decade. Clean energy sources (such as wind energy and solar energy) have considerable potential to reduce reliance on fossil fuels and mitigate climate change. However, wind energy is going to become more mainstream due to technological advancement and geographical availability. Therefore, various technologies exist to maximize the inherent advantages of using wind energy conversion systems (WECSs) to generate electrical power. One important technology is the power electronics interface that enables the transfer and effective control of electrical power from the renewable energy source to the grid through the filter and isolation transformer. However, the transformer is bulky, generates losses, and is also very costly. Therefore, the term "transformer-less connection" refers to eliminating a step-up transformer from the WECS, while the power conversion stage performs the conventional functions of a transformer. Existing power converter configurations for transformer-less connection of a WECS are either based on the generator-converter configuration or three-stage power converter configuration. These configurations consist of conventional multilevel converter topologies and two-stage power conversion between the generator-side converter topology and the high-order filter connected to the collection point of the wind power plant (WPP). Thus, the complexity and cost of these existing configurations are significant at higher voltage and power ratings. Therefore, a single-stage multilevel converter topology is proposed to simplify the power conversion stage of a transformer-less WECS. Furthermore, the primary design challenges – such as multiple clamping devices, multiple dc-link capacitors, and series-connected power semiconductor devices – have been mitigated by the proposed converter topology. The proposed converter topology, known as the "tapped inductor quasi-Z-source nested neutral-point-clamped (NNPC) converter," has been analyzed, and designed, and a prototype of the topology developed for experimental verification. A field-programmable gate array (FPGA)-based modulation technique and voltage balancing control technique for maintaining the clamping capacitor voltages was developed. Hence, the proposed converter topology presents a single-stage power conversion configuration. Efficiency analysis of the proposed converter topology has been studied and compared to the intermediate and grid-side converter topology of a three-stage power converter configuration. A direct current (DC) component minimization technique to minimize the dc component generated by the proposed converter topology was investigated, developed, and verified experimentally. The proposed dc component minimization technique consists of a sensing and measurement circuitry with a digital notch filter. This thesis presents a detailed and comprehensive overview of the existing power converter configurations developed for transformer-less WECS applications. Based on the developed 2 comparative benchmark factor (CBF), the merits and demerits of each power converter configuration in terms of the component counts and grid compliance have been presented. In terms of cost comparison, the three-stage power converter configuration is more cost-effective than the generatorconverter configuration. Furthermore, the cost-benefit analysis of deploying a transformer-less WECSs in a WPP is evaluated and compared with conventional WECS in a WPP based on power converter configurations and collection system. Overall, the total cost of the collection system of WPP with transformer-less WECSs is about 23% less than the total cost of WPP with conventional WECs. The derivation and theoretical analysis of the proposed five-level tapped inductor quasi-Z-source NNPC converter topology have been presented, emphasizing its operating principles, steady-state analysis, and deriving equations to calculate its inductance and capacitance values. Furthermore, the FPGA implementation of the proposed converter topology was verified experimentally with a developed prototype of the topology. The efficiency of the proposed converter topology has been evaluated by varying the switching frequency and loads. Furthermore, the proposed converter topology is more efficient than the five-level DC-DC converter with a five-level diode-clamped converter (DCC) topology under the three-stage power converter configuration. Also, the cost analysis of the proposed converter topology and the conventional converter topology shows that it is more economical to deploy the proposed converter topology at the grid side of a transformer-less WECS
    • …
    corecore