22,750 research outputs found

    Micro-CT for analysis of laser sintered micro-composites

    Get PDF
    Purpose X-Ray-computed micro-tomography (micro-CT) is relatively well established in additive manufacturing as a method to determine the porosity and geometry of printed parts and, in some cases, the presence of inclusions or contamination. This paper aims to demonstrate that micro-CT can also be used to quantitatively analyse the homogeneity of micro-composite parts, in this case created using laser sintering (LS). Design/methodology/approach LS specimens were manufactured in polyamide 12 with and without incorporation of a silver phosphate glass additive in different sizes. The specimens were scanned using micro-CT to characterise both their porosity and the homogeneity of dispersion of the additive throughout the volume. Findings This work showed that it was possible to use micro-CT to determine information related to both porosity and additive dispersion from the same scan. Analysis of the pores revealed the overall porosity of the printed parts, with linear elastic fracture mechanics used to identify any pores likely to lead to premature failure of the parts. Analysis of the additive was found to be possible above a certain size of particle, with the size distribution used to identify any agglomeration of the silver phosphate glass. The particle positions were also used to determine the complete spatial randomness of the additive as a quantitative measure of the dispersion. Practical implications This shows that micro-CT is an effective method of identifying both porosity and additive agglomeration within printed parts, meaning it can be used for quality control of micro-composites and to validate the homogeneity of the polymer/additive mixture prior to printing. Originality/value This is believed to be the first instance of micro-CT being used to identify and analyse the distribution of an additive within a laser sintered part

    Automated processing of series of micro-CT scans

    Get PDF
    For some applications of high-resolution X-ray Tomography (micro-CT) scanning, a large set of similar samples is to be analyzed in order to obtain statistically significant results. The complete process, including the micro-CT scan itself, the reconstruction and the analysis is almost identical for every sample. However, in a typical workflow every step is manually performed for every individual sample. This could be optimised by automation of this process, which results in less human intervention and thus a smaller cost and a lower risk to human error. We developed a reliable method to semi-automatically scan several stacked samples and automatically reconstruct the resulting series of data sets. The reconstruction step includes the manual reconstruction of one data set in order to optimize the reconstruction parameters, which can then be used for the rest of the batch. In future work, the automatic handling of the next step in the micro-CT workflow, 3D analysis, will also be improved

    Quantification of Bronchial Circulation Perfusion in Rats

    Get PDF
    The bronchial circulation is thought to be the primary blood supply for pulmonary carcinomas. Thus, we have developed a method for imaging and quantifying changes in perfusion in the rat lung due to development of the bronchial circulation. A dual-modality micro-CT/SPECT system was used to detect change in perfusion in two groups of rats: controls and those with a surgically occluded left pulmonary artery. Both groups were imaged following injections on separate days i) 2mCi of Tc99m labeled macroaggregated albumin (MAA) into the left carotid artery (IA) and ii) a similar injection into the femoral vein (IV). The IA injection resulted in Tc99m accumulation in capillaries of the systemic circulation including the bronchial circulation, whereas the IV resulted in Tc99m accumulation in the pulmonary capillaries. Ordered subset expectation maximization (OSEM) was used to reconstruct the SPECT image volumes and a Feldkamp algorithm was used to reconstruct the micro-CT image volumes. The micro-CT and SPECT volumes were registered, the SPECT image volume was segmented using the right and left lung boundaries defined from the micro-CT volume, and the ratio of IA radioactivity accumulation in the left lung to IV radioactivity accumulation in both lungs was used as a measure of left lung flow via the bronchial circulation. This ratio was ~0.02 for the untreated rats compared to the treated animals that had an increased flow ratio of ~0.21 40 days after left pulmonary artery occlusion. This increase in flow to the occluded left lung via the bronchial circulation suggests this will be a useful model for further investigating antiangiogenic treatments

    Quantification of Bronchial Circulation Perfusion in Rats

    Get PDF
    The bronchial circulation is thought to be the primary blood supply for pulmonary carcinomas. Thus, we have developed a method for imaging and quantifying changes in perfusion in the rat lung due to development of the bronchial circulation. A dual-modality micro-CT/SPECT system was used to detect change in perfusion in two groups of rats: controls and those with a surgically occluded left pulmonary artery. Both groups were imaged following injections on separate days i) 2mCi of Tc99m labeled macroaggregated albumin (MAA) into the left carotid artery (IA) and ii) a similar injection into the femoral vein (IV). The IA injection resulted in Tc99m accumulation in capillaries of the systemic circulation including the bronchial circulation, whereas the IV resulted in Tc99m accumulation in the pulmonary capillaries. Ordered subset expectation maximization (OSEM) was used to reconstruct the SPECT image volumes and a Feldkamp algorithm was used to reconstruct the micro-CT image volumes. The micro-CT and SPECT volumes were registered, the SPECT image volume was segmented using the right and left lung boundaries defined from the micro-CT volume, and the ratio of IA radioactivity accumulation in the left lung to IV radioactivity accumulation in both lungs was used as a measure of left lung flow via the bronchial circulation. This ratio was ~0.02 for the untreated rats compared to the treated animals that had an increased flow ratio of ~0.21 40 days after left pulmonary artery occlusion. This increase in flow to the occluded left lung via the bronchial circulation suggests this will be a useful model for further investigating antiangiogenic treatments

    Evaluation of the absorbed dose in X-ray microtomography

    Get PDF
    It is widely known that a sample receives a radiation absorbed dose during a CT-scan. Although this can have unwanted effects on the sample such as discolouration, little can be found in literature about the absorbed dose in micro-CT applications (except for small animal micro-CT). This research aims to validate the accuracy of dose simulations to be able to predict the dose before scanning the sample. Both Monte Carlo simulations with BEAMnrc and simulations with the in-house developed Setup Optimizer are compared with measurements with an ionisation chamber. The simulations nearly always underestimate the experimental values with a maximal deviation of 40%. In contrast the dose reduction after a layer of material obtained with the simulation programmes is relatively accurate

    Micro computed tomography assessment of tumor size in breast cancer compared to histopathological examination

    Full text link
    PURPOSE: The purpose of this study was to assess the ability of Micro Computed Tomography (Micro CT) to measure primary tumor size in breast lumpectomy specimens, as compared to the histopathological measurement. METHODS: This was a diagnostic study involving women who were scheduled to have breast lumpectomy surgery at the Massachusetts General Hospital (MGH) Department of surgery from June 2011 - September 2011. Those who met the study eligibility criteria were recruited to participate in the study. The study was approved by the MGH Institutional Review Board (IRB). All the participants provided consent prior to their participation in the study. The lumpectomy specimens of 45 subjects were scanned by Micro CT scan for no longer than 15 minutes, they were then delivered to the gross pathology lab for processing via the standard pathological protocol. Later on, the maximum dimension of the invasive breast tumor was obtained from the Micro CT image and was compared to the corresponding pathology report for each subject. RESULTS: We found that Micro CT tends to overestimate the breast malignant tumor size. However, there were few differences in T-stage classification between Micro CT and pathology. Overall, Micro CT demonstrated good agreement with pathological tumor size and staging. For Invasive ductal carcinoma, Micro CT showed a substantial agreement with pathological tumor size and staging. However, Micro CT showed no agreement with pathological tumor size and staging for invasive lobular carcinoma. CONCLUSIONS: Micro CT is a promising modality in measuring and staging the invasive ductal carcinoma

    Effects of deleting cannabinoid receptor-2 on mechanical and material properties of cortical and trabecular bone

    Get PDF
    Acknowledgements We thank Dr J.S. Gregory for assistance with Image J and Mr K. Mackenzie for assistance with Micro-CT analysis. Funding ABK was funded by a University of Aberdeen, Institute of Medical Sciences studentship and the Overseas Research Students Awards Scheme.Peer reviewedPublisher PD