27 research outputs found
Modular integration and on-chip sensing approaches for tunable fluid control polymer microdevices
228 p.Doktore tesi honetan mikroemariak kontrolatzeko elementuak diseinatu eta garatuko dira, mikrobalbula eta mikrosentsore bat zehazki. Ondoren, gailu horiek batera integratuko dira likido emari kontrolatzaile bat sortzeko asmotan. Helburu nagusia gailuen fabrikazio arkitektura modular bat frogatzea da, non Lab-on-a-Chip prototipoak garatzeko beharrezko fase guztiak harmonizatuz, Cyclic-Olefin-Polymer termoplastikozko mikrogailu merkeak pausu gutxi batzuetan garatuko diren, hauen kalitate industriala bermatuz. Ildo horretan, mikrogailuak prototipotik produkturako trantsizio azkar, erraz, errentagarri eta arriskurik gabeen bidez lortu daitezkeenetz frogatuko da
Liquid cooled micro-scale gradient system for magnetic resonance
Schaltbare magnetische Feldgradientspulen sind ein geeignetes Werkzeug für die Modulation der Kernspinpräzession in der gepulsten Kernspinresonanzspektroskopie und Bildgebung. Die Magnetresonanztomographie von mikroskopischen Proben benötigt starke, schnell schaltbare Magnetfeldgradienten, um diffusionsbedingte Artefakte zu unterdrücken, Suszeptibilitätseffekte abzuschwächen und um die Messzeit zu verkürzen. Verschiedene Techniken können eingesetzt werden, um eine hohe Gradientenintensität zu erreichen, wie zum Beispiel die Erhöhung der Stromstärke oder die Steigerung der Windungsdichte der Feldspule. Ein weiterer, geeigneter technischer Ansatz besteht darin, die Gradientenspulen näher an der Probe zu platzieren. Als Konsequenz wird aber die durch die Joule-Erwärmung verursachte Wärmeentwicklung zu einem zentralen Problem.
In dieser Arbeit wird ein neuartiges Design, ein Mikroherstellungsprozess und eine Kernspin-Evaluierung eines Feldgradientenchips präsentiert. Die Gradientenspulen wurden besonders hoch miniaturisiert und durch den Einsatz von verbesserten und neuartigen Strukturierungsverfahren entwickelt. Zuerst wird ein Fertigungsverfahren zur Herstellung einer kompakten Hochfrequenzspule vorgestellt. Durch den Einsatz einer maskenlosen Rückseitenlithographie konnte die Prozesskomplexität reduziert werden. Dieses Verfahren wurde durch Tintenstrahldruck mit Nanopartikeln realisiert, wobei die gedruckten Strukturen selbst als lithographische Maske für die Herstellung einer galvanischen Form dienen. Somit werden die Seitenwände der galvanischen Form durch die gedruckte Seed-Schicht optimal selbst ausgerichtet. Dies ermöglichte eine anisotrope Galvanisierung, um eine höhere elektrische Leitfähigkeit der gedruckten Leiterbahnen zu erzielen.
Aus den Erkenntnissen der ausgearbeiteten Herstellungsprozesse wurde ein optimiertes Spulendesign für ein-axiale sowie drei-axiale linearen Gradientenchips entwickelt. Die einachsige lineare -Gradientenspule wurde mit der Stream-Function-Methode berechnet, wobei die Optimierung darauf abgestimmt wurde, eine minimale Verlustleistung zu erzielen. Die Gradientenspulen wurden auf zwei Doppellagen implementiert, die mittels Cu-Galvanik in Kombination mit fotodefinierbaren Trockenfilm-Laminaten aufgebracht wurden. Bei dem hier vorgestellten Herstellungsverfahren diente die erste Metallisierungschicht gleichzeitig dazu, Widerstands-Temperaturdetektoren zu integrieren. Um niederohmige Spulen zu realisieren wurde der Galvanisierungsprozess soweit angepasst, um eine hohe Schichtdicke zu erzielen. Die Chipstruktur beinhaltet ein aktives Kühlsystem, um dem Aufheizen der Spulen entgegenzuwirken.
Thermographische Aufnahmen in Kombination mit den eingebetteten Temperatursensoren ermöglichen es, die Erhitzung der Spule zu analysieren, um die Strombelastbarkeit zu ermitteln. Die Gradientenspule wurde mit einer Hochfrequenz-Mikrospule in einer Flip-Chip-Konfiguration zusammengebaut, und mit diesem Aufbau wurde ein eindimensionales Kernspinexperiment durchgeführt. Es wurde eine Gradienteneffizienz von 3.15 bei einer Profillänge von 1.2 erreicht
Recommended from our members
Macro-meso-microsystems integration in LTCC : LDRD report.
Low Temperature Cofired Ceramic (LTCC) has proven to be an enabling medium for microsystem technologies, because of its desirable electrical, physical, and chemical properties coupled with its capability for rapid prototyping and scalable manufacturing of components. LTCC is viewed as an extension of hybrid microcircuits, and in that function it enables development, testing, and deployment of silicon microsystems. However, its versatility has allowed it to succeed as a microsystem medium in its own right, with applications in non-microelectronic meso-scale devices and in a range of sensor devices. Applications include silicon microfluidic ''chip-and-wire'' systems and fluid grid array (FGA)/microfluidic multichip modules using embedded channels in LTCC, and cofired electro-mechanical systems with moving parts. Both the microfluidic and mechanical system applications are enabled by sacrificial volume materials (SVM), which serve to create and maintain cavities and separation gaps during the lamination and cofiring process. SVMs consisting of thermally fugitive or partially inert materials are easily incorporated. Recognizing the premium on devices that are cofired rather than assembled, we report on functional-as-released and functional-as-fired moving parts. Additional applications for cofired transparent windows, some as small as an optical fiber, are also described. The applications described help pave the way for widespread application of LTCC to biomedical, control, analysis, characterization, and radio frequency (RF) functions for macro-meso-microsystems
Surface functionalization of silicon substrates via graft polymerization
Ph.DDOCTOR OF PHILOSOPH
Point of Care Molecular Diagnostics for Humanity
Diagnostics of disease at POC (point of care) has been declared one of the Grand Challenge by the Bill and Melina Gates Foundation (BMGF). Infectious diseases constitute a major cause of disease burden and cause more than half a billion Disability-Adjusted Life Years (DALYs) and millions of deaths each year. They have an especially large effect on children under 5 years of age. We have analyzed data from the GBD 2010 (Global Burden of Disease) project to emphasize the damage caused by infectious diseases, and highlight the opportunity of using diagnostic tools to rapidly identify and treat diseases. To motivate the work of this thesis, we quantify the expected impact of appropriate diagnostic technologies.
We have also analyzed the requirements that a diagnostic tool should meet to generate the maximal global impact. We present various existing TPPs (Target Product Profiles) from different organizations and suggest some additions to these existing TPPs. We explain the particular molecular pathology technologies which have the potential to allow deployment of functional products in the developing world for point-of-care pathogen detection, especially in low-resource settings.
We perform a detailed analysis on existing polymerase chain reaction (PCR) systems and describe the problems caused with thermal performance and optical interrogation. We list the requirements that disposable cartridges for such instruments should meet and suggest a metal base design with polymer top. After detailed FEA simulations, we demonstrate that the thermal response can be modeled using a one-dimensional (1D) lumped element system. We show improvements in thermal response due to using a metal base and the effect of fluid height. We also performed thermal-structural simulations to quantify the stresses on the adhesive bonds of metal/polymer cartridges.
Next, we explain fabrication of these cartridges. We show methods to dispense adhesive using a robot and a custom made jig to spread the adhesive during curing. The cartridge was tested with different PCR reagents and we obtained reaction efficiencies approaching those of the commercial real time PCR machines. Our fabrication technique is useful to join dissimilar materials and is production friendly. By developing custom software, we observed the cartridge performance in a continuous manner. We could see the thermal response of cartridges by continuous fluorescence monitoring, and used reflective aluminum which increase light collection efficiency.
We then present a simple and robust new way for thermal cycling. Robust thermal cycling has been a major challenge conducting PCR, especially in point of care situations. Here, we suggest a contact cooling approach, in which the cartridge rests on a thin metal plate with an integrated thin heater constructed from flexible printed circuit board (PCB) material. We use a solenoid to move a metal plate to cool down the sample cartridge during cycling. The metal plate then rests on a larger heat sink to disperse the shuttled heat. Our design is dust and water proof and was verified on a bench-top prototype.
A novel optical design for fluorescence detection during qPCR is also described. We suggest a lateral illumination waveguide geometry with prism coupling that eliminates lenses and is integrated into an injection molded cartridge. The light is homogenized using a light guide, and we quantify the sources of scattered stray light from the chamber edge by performing ray tracing simulations to optimize the precise geometry. The design is tolerant to misalignments and enables easy coupling of LED light into the chamber. As the light collection efficiency is high, the size of the chamber can be very small. We tested real PCR reactions using this concept and observed a rapid integration time, enabling very fast reading.
Sample preparation has been another challenge for all point-of-care (POC) lab-on-chip devices for many years. Here, we propose a new design which is robust, fast, flexible and simple, and uses a sliding seal to move the collected sample between various reservoir chambers. The sample moves on a slider sandwiched between seals that shuttles a DNA binding membrane between different reactions. Thus, size and volumes of reagents can be increased without increasing dead volumes. This design is easily automated, and positive displacement of fluids can work with many reagents without worrying about their characteristics such as foaming. The speed of the sample preparation protocols is high and complex protocols can be ported on this design concept, which we tested on real clinical samples and obtained impressive results. We designed and injection molded devices to test and verify this concept.
Finally, we focus on instrumentation and software required to allow our technology to be used at the POC. We describe our embedded electronics and describe the powerful micro-controller and various high performance ICs that are used to construct a fully functional for sample to answer instrument. We developed various versions of software. The developer software allows us to control our system and bench top setup. Our end user product includes a tablet and cell phone software interface. Software was developed for a windows 8 tablet, windows 8 phone and an Android based devices.
To conclude, we very briefly describe the POC systems that are under development: A portable qPCR system with a separate cartridge design, and a universal sample to answer system that performs qPCR, sample preparation and sample to answer protocols in one box depending on the cartridge.
As per best of our knowledge the cost of this technology is much lower than any other option in its class. The sample to answer instrument is expected to cost less than 5. The performance is not compromised. We hope that this work can help bring a transformative change in the practice of pathology especially in the developing world.</p
Electrical and Electro-Optical Biosensors
Electrical and electro-optical biosensing technologies are critical to the development of innovative POCT devices, which can be used by both professional and untrained personnel for the provision of necessary health information within a short time for medical decisions to be determined, being especially important in an era of global pandemics. This Special Issue includes a few pioneering works concerning biosensors utilizing electrochemical impedance, localized surface plasmon resonance, and the bioelectricity of sensing materials in which the amount of analyte is pertinent to the signal response. The presented results demonstrate the potential of these label-free biosensing approaches in the detection of disease-related small-molecule metabolites, proteins, and whole-cell entities
Proceedings of the 2018 Canadian Society for Mechanical Engineering (CSME) International Congress
Published proceedings of the 2018 Canadian Society for Mechanical Engineering (CSME) International Congress, hosted by York University, 27-30 May 2018
Biennial report ... / Leibniz-Institut für Oberflächenmodifizierung e.V.
damit Erscheinen eingestell