303 research outputs found
Euler analysis comparison with LDV data for an advanced counter-rotation propfan at cruise
A fine mesh Euler solution of the F4/A4 unducted fan (UDF) model flowfield is compared with laser Doppler velocimeter (LDV) data taken in the NASA Lewis 8- by 6-Foot Supersonic Wind Tunnel. The comparison is made primarily at one axial plane downstream of the front rotor where the LDV particle lag errors are reduced. The agreement between measured and predicted velocities in this axial plane is good. The results show that a dense mesh is needed in the centerbody stagnation region to minimize entropy generation that weakens the aft row passage shock. The predicted radial location of the tip vortex downstream of the front rotor agrees well with the experimental results but the strength is overpredicted. With 40 points per chord line, the integrated performance quantities are nearly converged, but more points are needed to resolve passage shocks and flow field details
A 6-12 GHz Analogue Lag-Correlator for Radio Interferometry
Aims: We describe a 6-12 GHz analogue correlator that has been developed for
use in radio interferometers. Methods: We use a lag-correlator technique to
synthesis eight complex spectral channels. Two schemes were considered for
sampling the cross-correlation function, using either real or complex
correlations, and we developed prototypes for both of them. We opted for the
``add and square'' detection scheme using Schottky diodes over the more
commonly used active multipliers because the stability of the device is less
critical. Results: We encountered an unexpected problem, in that there were
errors in the lag spacings of up to ten percent of the unit spacing. To
overcome this, we developed a calibration method using astronomical sources
which corrects the effects of the non-uniform sampling as well as gain error
and dispersion in the correlator.Comment: 14 pages, 21 figures, accepted for publication in A&
A 6-12 GHz Analogue Lag-Correlator for Radio Interferometry
Aims: We describe a 6-12 GHz analogue correlator that has been developed for
use in radio interferometers. Methods: We use a lag-correlator technique to
synthesis eight complex spectral channels. Two schemes were considered for
sampling the cross-correlation function, using either real or complex
correlations, and we developed prototypes for both of them. We opted for the
``add and square'' detection scheme using Schottky diodes over the more
commonly used active multipliers because the stability of the device is less
critical. Results: We encountered an unexpected problem, in that there were
errors in the lag spacings of up to ten percent of the unit spacing. To
overcome this, we developed a calibration method using astronomical sources
which corrects the effects of the non-uniform sampling as well as gain error
and dispersion in the correlator.Comment: 14 pages, 21 figures, accepted for publication in A&
Calibration of hygrometers at fluctuating and transient conditions
Hygrometers are normally calibrated under stable conditions. Relative humidity values in the climatic chamber fluctuate quite much at medium levels. In this work it was measured how much the relative humidity fluctuation in the climatic chamber affects the calibration of hygrometers. Also the time constants of different hygrometers were measured and the hygrometers were calibrated at drifting relative humidity values.
Even though the relative humidity values fluctuate in the climatic chamber at medium levels, this fluctuation has a minor effect in calibration. Even the slowest hygrometers can be calibrated under fluctuating conditions. Under drifting conditions the accuracy of calibration depends on the speed of the drift and the time constant of the hygrometer. The calibration of slowest hygrometers at drift speeds 0.5 %/min and 1 %/min can lead to significant lag errors
Millimeter and sub-millimeter atmospheric performance at Dome C combining radiosoundings and ATM synthetic spectra
The reliability of astronomical observations at millimeter and sub-millimeter
wavelengths closely depends on a low vertical content of water vapor as well as
on high atmospheric emission stability. Although Concordia station at Dome C
(Antarctica) enjoys good observing conditions in this atmospheric spectral
windows, as shown by preliminary site-testing campaigns at different bands and
in, not always, time overlapped periods, a dedicated instrument able to
continuously determine atmospheric performance for a wide spectral range is not
yet planned. In the absence of such measurements, in this paper we suggest a
semi-empirical approach to perform an analysis of atmospheric transmission and
emission at Dome C to compare the performance for 7 photometric bands ranging
from 100 GHz to 2 THz. Radiosoundings data provided by the Routine
Meteorological Observations (RMO) Research Project at Concordia station are
corrected by temperature and humidity errors and dry biases and then employed
to feed ATM (Atmospheric Transmission at Microwaves) code to generate synthetic
spectra in the wide spectral range from 100 GHz to 2 THz. To quantify the
atmospheric contribution in millimeter and sub-millimeter observations we are
considering several photometric bands in which atmospheric quantities are
integrated. The observational capabilities of this site at all the selected
spectral bands are analyzed considering monthly averaged transmissions joined
to the corresponding fluctuations. Transmission and pwv statistics at Dome C
derived by our semi-empirical approach are consistent with previous works. It
is evident the decreasing of the performance at high frequencies. We propose to
introduce a new parameter to compare the quality of a site at different
spectral bands, in terms of high transmission and emission stability, the Site
Photometric Quality Factor.Comment: accepted to MNRAS with minor revision
- …