33,588 research outputs found

    Development of a Targeted Mass Spectrometry Method for the Detection and Quantification of Peanut Protein in Incurred Food Matrices

    Get PDF
    The unintentional presence of peanut in food products through allergen cross-contact is a considerable safety concern for peanut-allergic individuals. The food industry monitors for this contamination using immunoassays; however, these detection methods demonstrate issues with recovery and accurate quantification of allergenic protein when analyzing processed, complex food matrices. Of particular concern is the deficit in immunoassay-based detection and quantification of peanut in cookie and dark chocolate matrices, as the unintentional presence of peanut has been observed in these food products. A liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of peanut protein in cookie and dark chocolate was developed to overcome the issues plaguing immunoassays in analysis of peanut in these matrices. Peanut-incurred cookie and dark chocolate matrices were generated at various concentrations of peanut. Untargeted MS analysis of incurred matrices identified and quantified peanut peptides. Peptides were subjected to selection criteria, based on abundance and robustness in matrix, to determine 32 (cookie) and 67 (dark chocolate) candidate target peptides for the method. Candidate peptides were filtered to determine robust and sensitive target peptides in each matrix using iterative rounds of targeted MS. Six (cookie) and seven (dark chocolate) final peptides were determined. This resulted in nine unique peanut peptides for the method. A quantitative strategy was developed based on stable isotope labeled (SIL) peptides and an external calibration to peanut flour (PF). Quantification was reported in parts per million (ppm) peanut protein. Optimization of various aspects of the method, including instrument parameters, LC, and sample preparation, improved the method’s sensitivity and variability. The LC-MS/MS method was evaluated with incurred matrices and demonstrated highly sensitive and reliable detection, even at low concentrations of peanut protein (1.24 ppm peanut protein in cookie and 2 ppm peanut protein in dark chocolate). This sensitivity is sufficient to detect peanut concentrations relevant for the most sensitive peanut-allergic individuals. Advisors: Philip E. Johnson and Melanie L. Down

    Optimization of High Field Asymmetric Waveform Ion Mobility Spectrometry to enhance the comprehensiveness of mass spectrometry-based proteomic analyses

    Full text link
    La grande complexité des échantillons biologiques peut compliquer l'identification des protéines et compromettre la profondeur et la couverture des analyses protéomiques utilisant la spectrométrie de masse. Des techniques de séparation permettant d’améliorer l’efficacité et la sélectivité des analyses LC-MS/MS peuvent être employées pour surmonter ces limitations. La spectrométrie de mobilité ionique différentielle, utilisant un champ électrique élevé en forme d'onde asymétrique (FAIMS), a montré des avantages significatifs dans l’amélioration de la transmission d'ions peptidiques à charges multiples, et ce, en réduisant les ions interférents. Dans ce contexte, l'objectif de cette thèse était d'explorer les capacités analytiques de FAIMS afin d'élargir à la fois la gamme dynamique de détection des protéines/peptides et la précision des mesures en protéomique quantitative par spectrométrie de masse. Pour cela, nous avons systématiquement intégré FAIMS dans des approches classiques en protéomique afin de déterminer les changements dynamiques du protéome humain en réponse à l’hyperthermie. Nous avons d’abord étudié les avantages de FAIMS par rapport à la quantification par marquage isobare (tandem mass tag, TMT). Cette approche permet le marquage d'ions peptidiques avec différents groupements chimiques dont les masses nominales sont identiques mais différant par leur distribution respective d'isotopes stables. Les ions peptidiques marqués par TMT produisent des ions rapporteurs de masses distinctes une fois fragmentés en MS/MS. Malheureusement, la co-sélection d'ions précurseurs conduit souvent à des spectres MS/MS chimériques et une approche plus lente basée sur le MS3 est nécessaire pour une quantification précise. Comme FAIMS améliore l’efficacité de séparation en transmettant sélectivement des ions en fonction de leur voltage de compensation (CV), nous avons obtenu moins de co-sélection de peptides. FAIMS a amélioré la quantification des peptides TMT au niveau MS2 et a permis d’obtenir 68% plus de peptides quantifiés par rapport aux analyses LC-MS/MS classiques, fournissant ainsi un aperçu plus vaste des changements dynamiques du protéome humain en réponse au stress thermique. De plus, nous avons étudié le marquage métabolique par incorporation d’acides aminés marqués par des isotopes stables en culture cellulaire (SILAC). Si des interférences co-éluent avec les isotopes SILAC, la quantification devient imprécise et les contreparties de SILAC peuvent être assignées de manière erronée aux ions interférants du chromatogramme, faussant ainsi le rapport SILAC. Le fractionnement post-ionisation FAIMS pourrait filtrer les ions appartenant au bruit de fond qui pourraient autrement être attribués à une paire ou à un triplet SILAC pour la quantification. Dans ce projet, FAIMS a été particulièrement bénéfique pour les espèces peu abondantes et s’est montré plus performant que le fractionnement par échange de cations (SCX). En outre, FAIMS a permis la séparation des phosphoisomères fréquemment observés dans les extraits complexes de phosphoprotéomes. Le troisième objectif de ce travail de recherche était d'explorer la séparation de l'état de charge et la transmission améliorée de peptides fortement chargés avec FAIMS et son application à l'analyse de peptides SUMOylés. FAIMS pourrait ainsi améliorer la transmission des peptides SUMOylés triplement chargés par rapport aux peptides tryptiques usuels, lesquels sont principalement doublement chargés. Ceci permettait l'enrichissement en phase gazeuse des ions peptides SUMOylés. FAIMS est une approche alternative plus simple pour fractionner les peptides SUMOylés, ce qui réduit les pertes d’échantillon et permet de simplifier le traitement des échantillons, tout en augmentant l’efficacité de séparation de manière plus automatisée et en ajoutant un ordre de grandeur de sensibilité. Le dernier objectif de cette thèse était d’améliorer l’instrumentation de FAIMS en le jumelant aux instruments à la fine pointe de la technologie. Avec un nouveau dispositif FAIMS, développé par nos collaborateurs chez Thermo Fisher Scientific, nous avons montré une amélioration dans la robustesse et la transmission des ions pour la nouvelle interface. Dans des expériences simples en protéomique shotgun, FAIMS a étendu la gamme dynamique d'un ordre de grandeur pour une couverture protéomique plus profonde par rapport aux analyses LC-MS/MS classiques. En outre, le fractionnement en phase gazeuse de FAIMS a généré moins d’analyses chimériques en MS2, ce qui a permis d’obtenir plus d’identifications et une meilleure quantification. Pour ce faire, nous avons directement comparé le LC-FAIMS-MS/MS au LC-MS/MS/MS en utilisant la sélection de précurseur synchrone (SPS) avec et sans fractionnement en phase inverse basique. Des mesures quantitatives comparables ont été obtenues pour toutes les méthodes, à l'exception du fait que FAIMS a parmi d’obtenir un nombre 2,5 fois plus grand de peptides quantifiables par rapport aux expériences sans FAIMS. Globalement, cette thèse met en évidence certains des avantages que FAIMS peut offrir aux expériences en protéomique en améliorant à la fois l'identification et la quantification des peptides.The high complexity of biological samples can confound protein identification and compromise the depth and coverage of mass spectrometry-based proteomic analyses. Separation techniques that provide improved peak capacity and selectivity of LC-MS/MS analyses are often sought to overcome these limitations. High-field asymmetric waveform ion mobility spectrometry (FAIMS), a differential ion mobility device, has shown significant advantages by enhancing the transmission of multiple-charged peptide ions by reducing singly-charged interferences. In this context, the goal of this thesis was to explore the analytical capabilities of FAIMS to extend both the dynamic range of proteins/peptides detection and the precision of quantitative proteomic measurements by mass spectrometry. For this, we systematically integrated FAIMS in standard workflows to monitor the dynamic changes of the human proteome in response to hyperthermia. We first studied the merits of FAIMS to aid isobaric labeling quantification with tandem mass tags (TMT). This approach allows the labeling of peptide ions with different chemical groups of identical nominal masses but differing in their respective distribution of stable isotopes. TMT-labeled peptide ions produce reporter ions of distinct masses once fragmented by MS/MS. Unfortunately, the co-selection of precursor ions often leads to chimeric MS/MS spectra, and a slower MS3 centric approach is needed for precise quantification. Since FAIMS improves peak capacity by selectively transmitting ions based on their compensation voltage (CV), we obtained less peptide co-selection. FAIMS improved TMT quantification at the MS2 level and achieved 68 % more quantified peptides compared to regular LC-MS/MS, providing a deeper insight into the dynamic changes of the human proteome in response to heat stress. Further, we investigated stable isotope labeling by amino acids in cell culture (SILAC) quantification. If interferences co-elute simultaneously with SILAC isotopomers, quantification becomes inaccurate and SILAC counterparts can be missassigned to interfering ions in the highly populated chromatogram, thus skewing the SILAC ratio. FAIMS post-ionization fractionation could filter out background ions that can otherwise be attributed to a SILAC pair/triplet for quantification. In this work, FAIMS was especially beneficial for low abundant species and outperformed the standard strong cation exchange (SCX) fractionation workflow. In addition, FAIMS allowed the separation of phosphoisomers that are frequently observed in complex phosphoproteome extracts. The third aim of this work explored the charge state separation and enhanced transmission of highly charged peptides with FAIMS and its application for SUMOylated peptide analysis. FAIMS could enhance the transmission of triply charged SUMOylated peptides over typical tryptic peptide that are predominantly doubly charged, by applying more negative CVs with FAIMS. This allowed for gas-phase enrichment of SUMOylated peptide ions. FAIMS is an alternate and more straightforward approach to fractionate SUMOylated peptides that reduced sample loss, avoided sample processing, while increasing peak capacity in a more automated manner and added one order of magnitude in sensitivity. The last aim of this thesis was to improve the FAIMS instrumentation by interfacing it to the latest state-of-the-art instruments. With a new FAIMS device developed by our collaborators at Thermo Fisher Scientific, we demonstrate the robustness and the improved ion transmission for the new interface. In simple shotgun proteomics, FAIMS extended the dynamic range by one order of magnitude for deeper proteome coverage compared to regular LC-MS/MS. Moreover, fewer MS2 chimeric scans were generated with FAIMS gas-phase fractionation, which garnered more identifications and better quantification. For this, we directly compared LC-FAIMS-MS/MS to LC-MS/MS/MS using synchronous precursor selection (SPS) with and without basic reverse phase fractionation. Comparable quantitative measurements were obtained for all methods, except that FAIMS provided a 2.5-fold increase in the number of quantifiable peptides compared with non-FAIMS experiments. Overall, this thesis highlights some of the advantages that FAIMS can provide for proteomics experiments by improving both peptide identification and quantification

    Liquid chromatography-tandem mass spectrometry - Application in the clinical laboratory

    Get PDF
    This review provides a concise survey of liquid chromatography tandem mass spectrometry (LCTMS) as an emerging technology in clinical chemistry. The combination of two mass spectrometers with an interposed collision cell characterizes LCTMS as an analytical technology on its own and not just as a more specific detector for HPLC compared with conventional techniques. In LCTMS, liquid chromatography is rather used for sample preparation but not for complete resolution of compounds of interest. The instrument technology of LCTMS is complex and comparatively expensive; however, in routine use, methods are far more rugged compared to conventional chromatographic techniques and enable highthroughput analyses with very limited manual handling steps. Moreover, compared to both gas chromatographymass spectrometry (GCMS) and conventional HPLC techniques, LCTMS is substantially more versatile with respect to the spectrum of analyzable compounds. For these reasons it is likely that LCTMS will gain far more widespread use in the clinical laboratory than HPLC and GCMS ever did. In this article, the key features of LCTMS are described, method development is explained, typical fields of application are discussed, and personal experiences are related

    An Automated Method for the Analysis of Stable Isotope Labeling Data in Proteomics

    Get PDF
    An algorithm is presented for the generation of a reliable peptide component peak table from liquid chromatography-mass spectrometry (LC-MS) and subsequent quantitative analysis of stable isotope coded peptide samples. The method uses chemical noise filtering, charge state fitting, and deisotoping toward improved analysis of complex peptide samples. Overlapping peptide signals in mass spectra were deconvoluted by correlation with modeled peptide isotopic peak profiles. Isotopic peak profiles for peptides were generated in silico from a protein database producing reference model distributions. Doublets of heavy and light labeled peak clusters were identified and compared to provide differential quantification of pairs of stable isotope coded peptides. Algorithms were evaluated using peptides from digests of a single protein and a seven-protein mixture that had been differentially coded with stable isotope labeling agents and mixed in known ratios. The experimental results correlated well with known mixing ratios

    Current challenges in software solutions for mass spectrometry-based quantitative proteomics

    Get PDF
    This work was in part supported by the PRIME-XS project, grant agreement number 262067, funded by the European Union seventh Framework Programme; The Netherlands Proteomics Centre, embedded in The Netherlands Genomics Initiative; The Netherlands Bioinformatics Centre; and the Centre for Biomedical Genetics (to S.C., B.B. and A.J.R.H); by NIH grants NCRR RR001614 and RR019934 (to the UCSF Mass Spectrometry Facility, director: A.L. Burlingame, P.B.); and by grants from the MRC, CR-UK, BBSRC and Barts and the London Charity (to P.C.

    High Sensitivity Mass Spectrometric Quantification of Serum Growth Hormone by Amphiphilic Peptide Conjugation

    Full text link
    Amphiphilic peptide conjugation affords a significant increase in sensitivity with protein quantification by electrospray-ionization mass spectrometry. This has been demonstrated here for human growth hormone in serum using N-(3-iodopropyl)-N,N,N-dimethyloctylammonium iodide (IPDOA-iodide) as derivatizing reagent. The signal enhancement achieved in comparison to the method without derivatization enables extension of the applicable concentration range down to the very low concentrations as encountered with clinical glucose suppression tests for patients with acromegaly. The method has been validated using a set of serum samples spiked with known amounts of recombinant 22 kDa growth hormone in the range of 0.48 to 7.65 \mug/L. The coefficient of variation (CV) calculated, based on the deviation of results from the expected concentrations, was 3.5% and the limit of quantification (LoQ) was determined as 0.4 \mug/L. The potential of the method as a tool in clinical practice has been demonstrated with patient samples of about 1 \mug/L

    Profiling of aminoxyTMT-labeled bovine milk oligosaccharides reveals substantial variation in oligosaccharide abundance between dairy cattle breeds.

    Get PDF
    Free milk oligosaccharides are bioactive molecules that function as prebiotics and prevent infections that commonly afflict developing infants. To date, few publications have examined the factors affecting bovine milk oligosaccharide production among cattle in the dairy industry. Here we have applied a high-throughput isobaric labeling technique to measure oligosaccharide abundances in milk collected from Danish Holstein-Friesian and Jersey dairy cattle by liquid chromatography-mass spectrometry. With a total of 634 milk samples, this collection represents the largest sample set used for milk oligosaccharide profiling in the current literature. This study is also the first to use isobaric labeling for the purpose of measuring free oligosaccharides in a real sample set. We have identified 13 oligosaccharides that vary significantly by breed, with most structures being more abundant in the milk of Jersey cattle. The abundances of several oligosaccharides were increased in second-parity cows, and correlations between the abundances of oligosaccharide pairs were identified, potentially indicating similarities in their synthetic pathways. Fucosylated oligosaccharide structures were widely identified among both breeds. Improving our understanding of oligosaccharide production will aid in developing strategies to recover these compounds from processing streams and may enable their use as a functional ingredient in foods for infants and adults

    Automated processing of whole blood samples for the determination of immunosuppressants by liquid chromatography tandem-mass spectrometry

    Get PDF
    Background: Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Methods: Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. Results: A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 mu g/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. Conclusions: The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods
    • …
    corecore