    Providing adhesion for a miniture mobile intra-abdominal device based on biomimetic principles

    Get PDF
    This paper investigates the surface adhesion characteristics required for a miniature mobile device to move around the abdominal cavity. Such a device must be capable of adhering to the tissue lining and move freely across the upper surface of the insufflated abdomen. Accordingly, the potential of utilising bioinspired solutions to facilitate wet adhesion is assessed

    Single-Site Colectomy With Miniature \u3ci\u3eIn Vivo\u3c/i\u3e Robotic Platform

    Get PDF
    There has been a continuing push to reduce the invasiveness of surgery by accessing the abdominal cavity through a single incision, such as with laparoendoscopic single-site (LESS) surgery. Although LESS procedures offer significant benefits, added complexities still inhibit the procedures. Robotic surgery is proving to be an excellent option to overcome these limitations. This paper presents the experimental results of the single-incision in vivo surgical robot (SISR), a multifunctional, dexterous, twoarmed robot capable of performing surgical tasks while overcoming the issues associated with manual LESS operations. In vivo surgical procedures have been used to demonstrate the efficacy of using a robotic platform over traditional laparoscopic tools. The most recent experimental test resulted in the first successful in vivo robotic LESS colectomy utilizing a robot completely contained within the abdominal cavity. In this test, SISR showed significant benefits including access to all quadrants in the peritoneal cavity and improved dexterity

    Anthropomorphic surgical system for soft tissue robot-assisted surgery

    Get PDF
    Over the past century, abdominal surgery has seen a rapid transition from open procedures to less invasive methods such as laparoscopy and robot-assisted minimally invasive surgery (R-A MIS). These procedures have significantly decreased blood loss, postoperative morbidity and length of hospital stay in comparison with open surgery. R-A MIS has offered refined accuracy and more ergonomic instruments for surgeons, further minimising trauma to the patient.This thesis aims to investigate, design and prototype a novel system for R-A MIS that will provide more natural and intuitive manipulation of soft tissues and, at the same time, increase the surgeon's dexterity. The thesis reviews related work on surgical systems and discusses the requirements for designing surgical instrumentation. From the background research conducted in this thesis, it is clear that training surgeons in MIS procedures is becoming increasingly long and arduous. Furthermore, most available systems adopt a design similar to conventional laparoscopic instruments or focus on different techniques with debatable benefits. The system proposed in this thesis not only aims to reduce the training time for surgeons but also to improve the ergonomics of the procedure.In order to achieve this, a survey was conducted among surgeons, regarding their opinions on surgical training, surgical systems, how satisfied they are with them and how easy they are to use. A concept for MIS robotic instrumentation was then developed and a series of focus group meetings with surgeons were run to discuss it. The proposed system, named microAngelo, is an anthropomorphic master-slave system that comprises a three-digit miniature hand that can be controlled using the master, a three-digit sensory exoskeleton. While multi-fingered robotic hands have been developed for decades, none have been used for surgical operations. As the system has a human centred design, its relation to the human hand is discussed. Prototypes of both the master and the slave have been developed and their design and mechanisms is demonstrated. The accuracy and repeatability of the master as well as the accuracy and force capabilities of the slave are tested and discussed

    Od preparowania czterogruczołowego do technik małoinwazyjnych. Małoinwazyjna paratyroidektomia jako obecny standard chirurgii pierwotnej nadczynności przytarczyc

    Get PDF
    Complete surgical resection of hyperfunctioning parathyriod tissue is essential for the treatment of primary hyperparathyroidism. During recent years, minimally invasive surgery has been successfully applied in neck exploration, because of significant developments of guidance by intraoperative scans, the use of quick, intraoperative PTH assay, and also preoperative imaging procedures such as high resolution ultrasonography and sestamibi scintigraphy. The results of operations which are performed with minimally invasive techniques are comparable to those of conventional surgery, and provide advantages with regard to cosmetic result, length of hospitalisation, and reduced post-operative pain.Całkowite chirurgiczne usunięcie nadczynnej tkanki gruczołowej jest kluczowe dla leczenia pierwotnej nadczynności przytarczyc. Podczas ostatnich lat, techniki chirurgii małoinwazyjnej były z sukcesem wprowadzane do preparowania tkanek szyi. Było to możliwe dzięki opracowaniu śródoperacyjnych metod lokalizowania zmienionej tkanki, szybkim testom oznaczającym stężenie PTH w surowicy ,jak również doskonaleniu technik obrazowania przedoperacyjnego, takich jak ultrasonografia wysokiej rozdzielczości czy scyntygrafia z wykorzystaniem sestamibi. Wyniki operacji z wykorzystaniem technik małoinwazyjnych są porównywalne z wynikami technik konwencjonalnych oraz wiążą się z zaletami, takimi jak skrócony okres hospitalizacji, zmniejszenie bólu pooperacyjnego czy lepszy efekt kosmetyczny

    Scalability study for robotic hand platform

    Get PDF
    The goal of this thesis project was to determine the lower limit of scale for the RIT robotic grasping hand. This was accomplished using a combination of computer simulation and experimental studies. A force analysis was conducted to determine the size of air muscles required to achieve appropriate contact forces at a smaller scale. Input variables, such as the actuation force and tendon return force, were determined experimentally. A dynamic computer model of the hand system was then created using Recurdyn. This was used to predict the contact (grasping) force of the fingers at full-scale, half-scale, and quarter-scale. Correlation between the computer model and physical testing was achieved for both a life-size and half-scale finger assembly. To further demonstrate the scalability of the hand design, both half and quarter-scale robotic hand rapid prototype assemblies were built using 3D printing techniques. This thesis work identified the point where further miniaturization would require a change in the manufacturing process to micro-fabrication. Several techniques were compared as potential methods for making a production intent quarter-scale robotic hand. Investment casting, Swiss machining, and Selective Laser Sintering were the manufacturing techniques considered. A quarter-scale robotic hand tested the limits of each technology. Below this scale, micro-machining would be required. The break point for the current actuation method, air muscles, was also explored. Below the quarter-scale, an alternative actuation method would also be required. Electroactive Polymers were discussed as an option for the micro-scale. In summary, a dynamic model of the RIT robotic grasping hand was created and validated as scalable at full and half-scales. The model was then used to predict finger contact forces at the quarter-scale. The quarter-scale was identified as the break point in terms of the current RIT robotic grasping hand based on both manufacturing and actuation. A novel, prototype quarter-scale robotic hand assembly was successfully built by an additive manufacturing process, a high resolution 3D printer. However, further miniaturization would require alternate manufacturing techniques and actuation mechanisms

    The Research on Soft Pneumatic Actuators in Italy: Design Solutions and Applications

    Get PDF
    Interest in soft actuators has increased enormously in the last 10 years. Thanks to their compliance and flexibility, they are suitable to be employed to actuate devices that must safely interact with humans or delicate objects or to actuate bio-inspired robots able to move in hostile environments. This paper reviews the research on soft pneumatic actuators conducted in Italy, focusing on mechanical design, analytical modeling, and possible application. A classification based on the geometry is proposed, since a wide set of architectures and manufacturing solutions are available. This aspect is confirmed by the extent of scenarios in which researchers take advantage of such systems’ improved flexibility and functionality. Several applications regarding bio-robotics, bioengineering, wearable devices, and more are presented and discussed

    ESPRESS.0: Eustachian Tube-Inspired Tactile Sensor Exploiting Pneumatics for Range Extension and SenSitivity Tuning

    Get PDF
    Optimising the sensitivity of a tactile sensor to a specific range of stimuli magnitude usually compromises the sensor’s widespread usage. This paper presents a novel soft tactile sensor capable of dynamically tuning its stiffness for enhanced sensitivity across a range of applied forces, taking inspiration from the Eustachian tube in the mammalian ear. The sensor exploits an adjustable pneumatic back pressure to control the effective stiffness of its 20 mm diameter elastomer interface. An internally translocated fluid is coupled to the membrane and optically tracked to measure physical interactions at the interface. The sensor can be actuated by pneumatic pressure to dynamically adjust its stiffness. It is demonstrated to detect forces as small as 0.012 N, and to be sensitive to a difference of 0.006 N in the force range of 35 to 40 N. The sensor is demonstrated to be capable of detecting tactile cues on the surface of objects in the sub-millimetre scale. It is able to adapt its compliance to increase its ability for distinguishing between stimuli with similar stiffnesses (0.181 N/mm difference) over a large range (0.1 to 1.1 N/mm) from only a 0.6 mm deep palpation. The sensor is intended to interact comfortably with skin, and the feasibility of its use in palpating tissue in search of hard inclusions is demonstrated by locating and estimating the size of a synthetic hard node embedded 20 mm deep in a soft silicone sample. The results suggest that the sensor is a good candidate for tactile tasks involving unpredictable or unknown stimuli

    Comparative Review of Endoscopic Devices Articulations Technologies Developed for Minimally Invasive Medical Procedures

    Get PDF
    This study introduces a comparative performance analysis of the technological solutions that have been used to build distal active articulations for minimally invasive medical procedures. The aim is to provide a practical and concise database and classification tool for anyone that wants to learn more about the technologies involved in minimally invasive medical devices, or for any designer interested in further improving these devices. A review of the different articulations developed in this field is therefore performed and organized by both actuation technology and structural architecture. Details are presented concerning the mechanical structures as well as the actuation and the mechanical transmission technologies available. The solutions are evaluated keeping as a reference some chosen required performances and characteristics for minimally invasive surgical procedures. Finally, a quantified comparison chart of these devices is given regarding selected criteria of interest for minimally invasive surgical application