    Institutional smart buildings energy audit

    Get PDF
    Smart buildings and Fuzzy based control systems used in Buildings Management System (BMS), Building Energy Management Systems (BEMS) and Building Automation Systems (BAS) are a point of interests among researcher and stake holders of buildings’ developing sector due to its ability to save energy and reduce greenhouse gas emissions. Therefore this paper will review, investigates define and evaluates the use of fuzzy logic controllers in smart buildings under subtropical Australia’s subtropical regions. In addition the paper also will define the latest development, design and proposed controlling strategies used in institutional buildings. Furthermore this paper will highlight and discuss the conceptual basis of these technologies including Fuzzy, Neural and Hybrid add-on technologies, its capabilities and its limitation

    Machine learning for estimation of building energy consumption and performance:a review

    Get PDF
    Ever growing population and progressive municipal business demands for constructing new buildings are known as the foremost contributor to greenhouse gasses. Therefore, improvement of energy eciency of the building sector has become an essential target to reduce the amount of gas emission as well as fossil fuel consumption. One most eective approach to reducing CO2 emission and energy consumption with regards to new buildings is to consider energy eciency at a very early design stage. On the other hand, ecient energy management and smart refurbishments can enhance energy performance of the existing stock. All these solutions entail accurate energy prediction for optimal decision making. In recent years, articial intelligence (AI) in general and machine learning (ML) techniques in specic terms have been proposed for forecasting of building energy consumption and performance. This paperprovides a substantial review on the four main ML approaches including articial neural network, support vector machine, Gaussian-based regressions and clustering, which have commonly been applied in forecasting and improving building energy performance

    A systematic literature review on the use of artificial intelligence in energy self-management in smart buildings

    Get PDF
    Buildings are one of the main consumers of energy in cities, which is why a lot of research has been generated around this problem. Especially, the buildings energy management systems must improve in the next years. Artificial intelligence techniques are playing and will play a fundamental role in these improvements. This work presents a systematic review of the literature on researches that have been done in recent years to improve energy management systems for smart building using artificial intelligence techniques. An originality of the work is that they are grouped according to the concept of "Autonomous Cycles of Data Analysis Tasks", which defines that an autonomous management system requires specialized tasks, such as monitoring, analysis, and decision-making tasks for reaching objectives in the environment, like improve the energy efficiency. This organization of the work allows us to establish not only the positioning of the researches, but also, the visualization of the current challenges and opportunities in each domain. We have identified that many types of researches are in the domain of decision-making (a large majority on optimization and control tasks), and defined potential projects related to the development of autonomous cycles of data analysis tasks, feature engineering, or multi-agent systems, among others.European Commissio

    Review of Intelligent Control Systems for Natural Ventilation as Passive Cooling Strategy for UK Buildings and Similar Climatic Conditions

    Get PDF
    Natural ventilation is gaining more attention from architects and engineers as an alternative way of cooling and ventilating indoor spaces. Based on building types, it could save between 13 and 40% of the building cooling energy use. However, this needs to be implemented and operated with a well-designed and integrated control system to avoid triggering discomfort for occupants. This paper seeks to review, discuss, and contribute to existing knowledge on the application of control systems and optimisation theories of naturally ventilated buildings to produce the best performance. The study finally presents an outstanding theoretical context and practical implementation for researchers seeking to explore the use of intelligent controls for optimal output in the pursuit to help solve intricate control problems in the building industry and suggests advanced control systems such as fuzzy logic control as an effective control strategy for an integrated control of ventilation, heating and cooling systems

    A multi-dimensional energy-based analysis of neighbourhood sustainability assessment tools: are institutional indicators really missing?

    Get PDF
    Neighbourhood Sustainability Assessment Tools (NSATs) have become the modern day template for urban planners to achieve sustainable development in their communities, districts and cities. The popularity of the pioneering NSATs led to the creation of other tools in different regions. Also, with the popularity and replication of these tools came the replication of their limitations. The most notable limitation and motivation for this study is the inadequate recognition of the complexities of institutional dimensions (i.e. policies, laws and regulation) that contribute to mainstreaming and operationalising sustainable neighbourhood development. Studies that have investigated NSATs generally argue lack of coverage of the institutional dimension. However, there has been little consistent and explicit mention of the precise indicators and criteria sought out to make this claim. Also, there is a clear confusion as to what institutional indicators actually are, what characteristics they possess and how best they can be identified. This study, via the lens of energy-based indicators, expands on the role of the institutional indicator and its associated dimensions. This study also utilises a multi-dimensional approach to indicator analysis and draws out current trend or characteristics of institutional indicators in 15 currently existing NSATs. The results show a limited view on the classification of institutional indicators. The study also demonstrates that there are more institutional indicators than previously reported in prior studies. Additionally, this study confirms that an institutional indicator cannot be a single entity or identity but rather it must operate under the linkage of the other dimensions (environment, social and economic). Finally, this study, based on the analysis of 15 NSATs provides a definition of what can be considered an institutional indicator. In conclusion, it is recommended that future development of NSATs should ensure a constant institutional link to indicators, as this could provide an enhanced alternative to the development of NSATs, particularly for regions that are looking into developing their own assessment tools

    Laboratory prediction energy control system based on artificial intelligence network

    Get PDF
    The use of electrical energy increases globally every year. The laboratory prediction energy control system (LPECS) predicted energy demand. This research was conducted in the Electrical Engineering Vocational Education laboratory by comparing the artificial neural fuzzy system (ANFIS) with the fuzzy logic. The comparison of methods aimed to determine their reliability in the energy demand prediction systems. The results showed that the minimum value of the target data using the conventional method (actual data) was 44.42%. Meanwhile, the prediction data using the ANFIS method was 44.33%, and the prediction data using the fuzzy method was 59.31%. The maximum value of the conventional ways (actual data) of ANFIS and fuzzy was similar by 77.59%. The RMSE ANFIS value was 0.1355%, the mean absolute percentage error (MAPE) was 0.2791%, and the fuzzy logic was 0.1986%. Thus, the ANFIS is applicable to determine the minimum and maximum values. Meanwhile, fuzzy can only show the maximum value but cannot reach the minimum value properly

    Deployment and control of adaptive building facades for energy generation, thermal insulation, ventilation and daylighting: A review

    Get PDF
    A major objective in the design and operation of buildings is to maintain occupant comfort without incurring significant energy use. Particularly in narrower-plan buildings, the thermophysical properties and behaviour of their façades are often an important determinant of internal conditions. Building facades have been, and are being, developed to adapt their heat and mass transfer characteristics to changes in weather conditions, number of occupants and occupant’s requirements and preferences. Both the wall and window elements of a facade can be engineered to (i) harness solar energy for photovoltaic electricity generation, heating, inducing ventilation and daylighting (ii) provide varying levels of thermal insulation and (iii) store energy. As an adaptive façade may need to provide each attribute to differing extents at particular times, achieving their optimal performance requires effective control. This paper reviews key aspects of current and emerging adaptive façade technologies. These include (i) mechanisms and technologies used to regulate heat and mass transfer flows, daylight, electricity and heat generation (ii) effectiveness and responsiveness of adaptive façades, (iii) appropriate control algorithms for adaptive facades and (iv) sensor information required for façade adaptations to maintain desired occupants’ comfort levels while minimising the energy use
    • …