331 research outputs found

    Enhancement of VCO Linearity and Phase Noise by Implementing Frequency Locked Loop

    Get PDF
    This paper investigates the on-chip implementation of a frequency locked loop (FLL) over a VCO that decreases the phase noise and linearizes the transfer function. Implementation of the FLL inside a PLL is also investigated and a possible application is highlighted. Design of a special kind of low noise frequency detector without a reference frequency (frequency-to-voltage converter), which is the most critical component of the FLL, is also presented in a 0.25 Âżm BiCMOS process. Linearization and approximately 15 dBc/Hz phase noise suppression is demonstrated over a moderate phase noise LC VCO with a center frequency of 10 GHz

    Self-Tuning Adaptive-Controller Using Online Frequency Identification

    Get PDF
    A real time adaptive controller was designed and tested successfully on a fourth order laboratory dynamic system which features very low structural damping and a noncolocated actuator sensor pair. The controller, implemented in a digital minicomputer, consists of a state estimator, a set of state feedback gains, and a frequency locked loop (FLL) for real time parameter identification. The FLL can detect the closed loop natural frequency of the system being controlled, calculate the mismatch between a plant parameter and its counterpart in the state estimator, and correct the estimator parameter in real time. The adaptation algorithm can correct the controller error and stabilize the system for more than 50% variation in the plant natural frequency, compared with a 10% stability margin in frequency variation for a fixed gain controller having the same performance at the nominal plant condition. After it has locked to the correct plant frequency, the adaptive controller works as well as the fixed gain controller does when there is no parameter mismatch. The very rapid convergence of this adaptive system is demonstrated experimentally, and can also be proven with simple root locus methods

    Multi-resonant frequency-locked loop for grid synchronization of power converters under distorted grid conditions

    Get PDF
    This paper presents a new multiresonant frequencyadaptive synchronization method for grid-connected power converters that allows estimating not only the positive- and negative-sequence components of the power signal at the fundamental frequency but also other sequence components at other harmonic frequencies. The proposed system is calledMSOGI-FLL since it is based on both a harmonic decoupling network consisting of multiple second-order generalized integrators (MSOGIs) and a frequency-locked loop (FLL), which makes the system frequency adaptive. In this paper, the MSOGI-FLL is analyzed for singleand three-phase applications, deducing some key expressions regarding its stability and tuning. Moreover, the performance of the MSOGI-FLL is evaluated by both simulations and experiments to show its capability for detecting different harmonic components in a highly polluted grid scenario.Peer ReviewedPostprint (published version

    Frequency and fundamental signal measurement algorithms for distributed control and protection applications

    Get PDF
    Increasing penetration of distributed generation within electricity networks leads to the requirement for cheap, integrated, protection and control systems. To minimise cost, algorithms for the measurement of AC voltage and current waveforms can be implemented on a single microcontroller, which also carries out other protection and control tasks, including communication and data logging. This limits the frame rate of the major algorithms, although analogue to digital converters (ADCs) can be oversampled using peripheral control processors on suitable microcontrollers. Measurement algorithms also have to be tolerant of poor power quality, which may arise within grid-connected or islanded (e.g. emergency, battlefield or marine) power system scenarios. This study presents a 'Clarke-FLL hybrid' architecture, which combines a three-phase Clarke transformation measurement with a frequency-locked loop (FLL). This hybrid contains suitable algorithms for the measurement of frequency, amplitude and phase within dynamic three-phase AC power systems. The Clarke-FLL hybrid is shown to be robust and accurate, with harmonic content up to and above 28% total harmonic distortion (THD), and with the major algorithms executing at only 500 samples per second. This is achieved by careful optimisation and cascaded use of exact-time averaging techniques, which prove to be useful at all stages of the measurements: from DC bias removal through low-sample-rate Fourier analysis to sub-harmonic ripple removal. Platform-independent algorithms for three-phase nodal power flow analysis are benchmarked on three processors, including the Infineon TC1796 microcontroller, on which only 10% of the 2000 mus frame time is required, leaving the remainder free for other algorithms

    Performance of PLL based DSGCPS and FLL controlled SSGCPS under normal condition and different grid faults: A comparative study

    Get PDF
    This paper presents two separate studies to address the increasing need for renewable energy sources in the grid to cope with the rising energy consumption. Firstly, a Double Stage Grid Connected Photovoltaic System (DSGCPS) based on Phase Locked Loops (PLL) is developed using Matlab-Simulink. Secondly, a model of a single-stage grid-connected photovoltaic system (SSGCPS) controlled by a frequency locked loop (FLL) is created with comparable environmental parameters and a loading pattern. The research compares the active and reactive power flow dynamics and DC link voltage fluctuations of both systems. Results indicate that the SSGCPS is the preferred option due to its lower hardware requirements. However, it has a lower performance in cases of grid faults compared to DSGCPS. Moreover, the study analyzes the Total Harmonic Distortion (THD) of both models, a crucial factor for performance analysis. The comparative study shows that DSGCPS performs better than SSGCPS during fault in terms of THD. In conclusion, it can be inferred that both models have unique advantages and disadvantages, which are contingent on specific operating conditions

    High Dynamic Optimized Carrier Loop Improvement for Tracking Doppler Rates

    Get PDF
    Mathematical analysis and optimization of a carrier tracking loop are presented. Due to fast changing of the carrier frequency in some satellite systems, such as Low Earth Orbit (LEO) or Global Positioning System (GPS), or some planes like Unmanned Aerial Vehicles (UAVs), high dynamic tracking loops play a very important role. In this paper an optimized tracking loop consisting of a third-order Phase Locked Loop (PLL) assisted by a second-order Frequency Locked Loop (FLL) for UAVs is proposed and discussed. Based on this structure an optimal loop has been designed. The main advantages of this approach are the reduction of the computation complexity and smaller phase error. The paper shows the simulation results, comparing them with a previous work

    Modeling and Analysis of SOGI-PLL/FLL-based Synchronization Units: Stability Impacts of Different Frequency-feedback Paths

    Get PDF
    — Second-order Generalized Integrator (SOGI)-based quadrature-signal-generator (QSG) together with either a phaselocked-loop (PLL) or a frequency-locked-loop (FLL) constitute two types of typical synchronization units (i.e., SOGI-PLL and - FLL) that have been widely used in grid-tied converter systems. This paper will reveal and clarify the stability issue of these two synchronization units arising from different implementations of the frequency-feedback-path (FFP) connecting the SOGI-QSG and the PLL/FLL. In this regard, four types of FFP implementations that are frequently seen in the literature will be discussed. Although different implementations of the FFP will not affect the steady-state frequency adaptation, their dynamical effects on the small-signal stability of SOGI-PLL/FLL remain concealed. To this end, this paper will present a comprehensive stability assessment and comparative analysis of SOGI-PLL/FLL focusing on the FFP issue. To extend the applicability and accuracy of discussions, all the analyses will be fulfilled by using a parameter space-oriented stability assessment method formulated in the linear-time periodic (LTP) framework. The obtained results are verified by time-domain simulations, and the main findings are further interpreted by using appropriate analytical models. Index Terms— FLL, PLL, synchronization, SOGI, stability, LTP, frequency feedback.acceptedVersio

    Is Using A Complex Control Gain in Three-phase FLLs Reasonable?

    Get PDF
    • 

    corecore