4,229 research outputs found

    Harmonic effects on induction and line start permanent magnet machines

    Get PDF
    Power Electronics (PE) are implemented in a wide variety of appliances, either to increase its controllability or energy efficiency, or simply because a DC supply is needed. The massive integration of rectifiers has resulted in a decrease of the supply voltage quality. Although PE have enabled the end user to control electrical machines, the resulting distortion inversely affects Direct On-Line (DOL) machines. In this paper a review is presented of the influence of these supply anomalies on Induction Motors (IM). The suggested problems have already been subject of much study. However, as new DOL technologies are emerging, for example Line Start Permanent Magnet Machines or Induction Generator systems, the influence of supply distortion on these systems should also be considered. This paper will present a comprehensive overview of the loss mechanisms, the magnitude of the losses and the impact of these losses on operation of IM, LSPMM and IG

    Introduction to State Estimation of High-Rate System Dynamics

    Get PDF
    Engineering systems experiencing high-rate dynamic events, including airbags, debris detection, and active blast protection systems, could benefit from real-time observability for enhanced performance. However, the task of high-rate state estimation is challenging, in particular for real-time applications where the rate of the observer’s convergence needs to be in the microsecond range. This paper identifies the challenges of state estimation of high-rate systems and discusses the fundamental characteristics of high-rate systems. A survey of applications and methods for estimators that have the potential to produce accurate estimations for a complex system experiencing highly dynamic events is presented. It is argued that adaptive observers are important to this research. In particular, adaptive data-driven observers are advantageous due to their adaptability and lack of dependence on the system model

    Assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring

    Get PDF
    Different methods have been developed to estimate the energy efficiency of induction motors. The accuracy of these methods vary with the load factor, the unbalanced voltage (UV) and harmonics. The feasibility of these methods for efficiency estimation in real-time were theoretically and experimentally assessed during the operation under different operational conditions (i.e. balanced sinusoidal voltage (BSV), harmonics, UV and harmonics with UV). Results show that for load factors over 80%, the air-gap method is applicable under any condition, while the slip method is only applicable under BSV or balanced harmonic voltage. Moreover, for load factors over 40%, the nameplate method is applicable under BSV. Other methods result in errors over 8% and optimization methods are not applicable for real-time monitoring. Electric systems generally operates with some degree of UV and harmonics, while induction motors mostly operate with load factors below 60%, limiting the use of these methods for real-time measurement

    Advanced Kalman Filter for Current Estimation in AC Microgrids

    Get PDF

    Improved rotor flux estimation at low speeds for torque MRAS-based sensorless induction motor drives

    Get PDF
    In this paper, an improved rotor flux estimation method for the Torque model reference adaptive schemes (TMRAS) sensorless induction machine drive is proposed to enhance its performance in low and zero speed conditions. The conventional TMRAS scheme uses an open loop flux estimator and a feedforward term, with basic low pass filters replacing the pure integrators. However, the performance of this estimation technique has drawbacks at very low speeds with incorrect flux estimation significantly affecting this inherently sensorless scheme. The performance of the proposed scheme is verified by both simulated and experimental testing for an indirect vector controlled 7.5-kW induction machine. Results show the effectiveness of the proposed estimator in the low- and zero-speed regions with improved robustness against motor parameter variation compared to the conventional method

    The 25 kWe solar thermal Stirling hydraulic engine system: Conceptual design

    Get PDF
    The conceptual design and analysis of a solar thermal free-piston Stirling hydraulic engine system designed to deliver 25 kWe when coupled to a 11 meter test bed concentrator is documented. A manufacturing cost assessment for 10,000 units per year was made. The design meets all program objectives including a 60,000 hr design life, dynamic balancing, fully automated control, more than 33.3 percent overall system efficiency, properly conditioned power, maximum utilization of annualized insolation, and projected production costs. The system incorporates a simple, rugged, reliable pool boiler reflux heat pipe to transfer heat from the solar receiver to the Stirling engine. The free-piston engine produces high pressure hydraulic flow which powers a commercial hydraulic motor that, in turn, drives a commercial rotary induction generator. The Stirling hydraulic engine uses hermetic bellows seals to separate helium working gas from hydraulic fluid which provides hydrodynamic lubrication to all moving parts. Maximum utilization of highly refined, field proven commercial components for electric power generation minimizes development cost and risk

    Power quality and electromagnetic compatibility: special report, session 2

    Get PDF
    The scope of Session 2 (S2) has been defined as follows by the Session Advisory Group and the Technical Committee: Power Quality (PQ), with the more general concept of electromagnetic compatibility (EMC) and with some related safety problems in electricity distribution systems. Special focus is put on voltage continuity (supply reliability, problem of outages) and voltage quality (voltage level, flicker, unbalance, harmonics). This session will also look at electromagnetic compatibility (mains frequency to 150 kHz), electromagnetic interferences and electric and magnetic fields issues. Also addressed in this session are electrical safety and immunity concerns (lightning issues, step, touch and transferred voltages). The aim of this special report is to present a synthesis of the present concerns in PQ&EMC, based on all selected papers of session 2 and related papers from other sessions, (152 papers in total). The report is divided in the following 4 blocks: Block 1: Electric and Magnetic Fields, EMC, Earthing systems Block 2: Harmonics Block 3: Voltage Variation Block 4: Power Quality Monitoring Two Round Tables will be organised: - Power quality and EMC in the Future Grid (CIGRE/CIRED WG C4.24, RT 13) - Reliability Benchmarking - why we should do it? What should be done in future? (RT 15

    Data-Driven Situation Awareness for Power System Frequency Dynamics

    Get PDF
    As the penetration of renewable energy increases, system inertia decreases, causing changes in system frequency dynamics. The power industry desires situation awareness of power system frequency dynamics to ensure secure and economic operation and control. Moreover, FNET/Grideye has abundant measured data from power systems, making it possible to conduct data-driven situation awareness studies on power system frequency dynamics. This doctoral dissertation proposes several contributions: (a) Two accurate generator trip event MW estimation methods are proposed, in which one is based on long window RoCoF and another is based on multi-Beta values; (b) Two real-time system inertia estimation approaches are developed using ambient frequency fluctuation and pump turn-off events, along with techniques for improving RoCoF calculation in event-based inertia estimation; (c) An adaptive PV reserve estimation algorithm is established to provide PV reserve while saving energy for PV resources; (d) A practical load composition estimation tool is built for the industry to easily obtain essential load model parameters. Although conducting research using actual data from power systems for practical application is challenging and compilated, the proposed data-driven situation awareness methods in this doctoral dissertation solve practical problems and offer clear theoretical explanations for the industry. These methods address one of the key challenges for operating a high-renewable power grid and pave the way for the U.S. carbon-free power sector by 2035
    corecore